Regional-surface-based registration for image-guided neurosurgery: effects of scan modes on registration accuracy

被引:13
作者
Dong, Yuan [1 ,2 ]
Zhang, Chenxi [1 ,2 ]
Ji, Dafeng [1 ,2 ,3 ]
Wang, Manning [1 ,2 ]
Song, Zhijian [1 ,2 ]
机构
[1] Fudan Univ, Sch Basic Med Sci, Digital Med Res Ctr, Shanghai, Peoples R China
[2] Shanghai Key Lab Med Imaging Comp & Comp Assisted, Shanghai, Peoples R China
[3] Nantong Univ, Dept Anat, Sch Med, Nantong, Peoples R China
基金
中国国家自然科学基金;
关键词
Image-guided neurosurgery; Regional-surface-based registration; Point-based registration; Target registration error; PATIENT REGISTRATION; RESOLUTION; GUIDANCE; SURGERY;
D O I
10.1007/s11548-019-01990-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThe conventional surface-based method only registers the facial zone with preoperative point cloud, resulting in low accuracy away from the facial area. Acquiring a point cloud of the entire head for registration can improve registration accuracy in all parts of the head. However, it takes a long time to collect a point cloud of the entire head. It may be more practical to selectively scan part of the head to ensure high registration accuracy in the surgical area of interest. In this study, we investigate the effects of different scan regions on registration errors in different target areas when using a surface-based registration method.MethodsWe first evaluated the correlation between the laser scan resolution and registration accuracy to determine an appropriate scan resolution. Then, with the appropriate resolution, we explored the effects of scan modes on registration error in computer simulation experiments, phantom experiments and two clinical cases. The scan modes were designed based on different combinations of five zones of the head surface, i.e., the sphenoid-frontal zone, parietal zone, left temporal zone, right temporal zone and occipital zone. In the phantom experiment, a handheld scanner was used to acquire a point cloud of the head. A head model containing several tumors was designed, enabling us to calculate the target registration errors deep in the brain to evaluate the effect of regional-surface-based registration.ResultThe optimal scan modes for tumors located in the sphenoid-frontal, parietal and temporal areas are mode 4 (i.e., simultaneously scanning the sphenoid-frontal zone and the temporal zone), mode 4 and mode 6 (i.e., simultaneously scanning the sphenoid-frontal zone, the temporal zone and the parietal zone), respectively. For the tumor located in the occipital area, no modes were able to achieve reliable accuracy.ConclusionThe results show that selecting an appropriate scan resolution and scan mode can achieve reliable accuracy for use in sphenoid-frontal, parietal and temporal area surgeries while effectively reducing the operation time.
引用
收藏
页码:1303 / 1315
页数:13
相关论文
共 50 条
  • [21] Multimodal Registration for Image-Guided EBUS Bronchoscopy
    Zang, Xiaonan
    Zhao, Wennan
    Toth, Jennifer
    Bascom, Rebecca
    Higgins, William
    JOURNAL OF IMAGING, 2022, 8 (07)
  • [22] Comparison of the Accuracy of Invasive and Noninvasive Registration Methods for Image-Guided Oral Implant Surgery
    Widmann, Gerlig
    Stoffner, Rudolf
    Schullian, Peter
    Widmann, Roland
    Keiler, Martin
    Zangerl, Antoniette
    Puelacher, Wolfgang
    Bale, Reto Josef
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 491 - 498
  • [23] Evaluation of errors influencing accuracy in image-guided neurosurgery
    Watanabe Y.
    Fujii M.
    Hayashi Y.
    Kimura M.
    Murai Y.
    Hata M.
    Sugiura A.
    Tsuzaka M.
    Wakabayashi T.
    Radiological Physics and Technology, 2009, 2 (2) : 120 - 125
  • [24] Asymmetrical surface scanning registration for image-guided otologic surgery: A phantom study
    Matsumoto, Nozomu
    Yamashita, Makoto
    Cho, Byunghyun
    Komune, Noritaka
    Hashizume, Makoto
    AURIS NASUS LARYNX, 2020, 47 (04) : 574 - 579
  • [25] An ITK implementation of a physics-based non-rigid registration method for brain deformation in image-guided neurosurgery
    Liu, Yixun
    Kot, Andriy
    Drakopoulos, Fotis
    Yao, Chengjun
    Fedorov, Andriy
    Enquobahrie, Andinet
    Clatz, Olivier
    Chrisochoides, Nikos P.
    FRONTIERS IN NEUROINFORMATICS, 2014, 8
  • [26] High-Accuracy Patient-to-Image Registration for the Facilitation of Image-Guided Robotic Microsurgery on the Head
    Gerber, Nicolas
    Gavaghan, Kate A.
    Bell, Brett J.
    Williamson, Tom M.
    Weisstanner, Christian
    Caversaccio, Marco-Domenico
    Weber, Stefan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) : 960 - 968
  • [27] Validation of anatomical landmarks-based registration for image-guided surgery: An in-vitro study
    Sun, Yi
    Luebbers, Heinz-Theo
    Agbaje, Jimoh Olubanwo
    Schepers, Serge
    Vrielinck, Luc
    Lambrichts, Ivo
    Politis, Constantinus
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2013, 41 (06) : 522 - 526
  • [28] Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT)
    Sharma, Shamurailatpam Dayananda
    Dongre, Prabhakar
    Mhatre, Vaibhav
    Heigrujam, Malhotra
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (03) : 311 - 319
  • [29] A projected landmark method for reduction of registration error in image-guided surgery systems
    Serej, Nasim Dadashi
    Ahmadian, Alireza
    Mohagheghi, Saeed
    Sadrehosseini, Seyed Musa
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 (05) : 541 - 554
  • [30] Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy
    Al-Mayah, Adil
    Moseley, Joanne
    Velec, Mike
    Brock, Kristy
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15) : 4701 - 4713