Coupling capacitor voltage transformer: A model for electromagnetic transient studies

被引:29
作者
Fernandes, D., Jr.
Neves, W. L. A.
Vasconcelos, J. C. A.
机构
[1] Fed Univ Campina Grande, Dept Elect Engn, BR-58109970 Campina Grande, PB, Brazil
[2] Companhia Hidro Eletrica Sao Francisco, BR-50761901 Recife, PE, Brazil
关键词
coupling capacitor voltage transformer; ferroresonance; optimization methods; overvoltage protection; power system transients;
D O I
10.1016/j.epsr.2006.02.007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, an accurate coupling capacitor voltage transformer (CCVT) model for electromagnetic transient studies is presented. The model takes into account linear and nonlinear elements. A support routine was developed to compute the linear 230 kV CCVT parameters (resistances, inductances and capacitances) from frequency response data. The magnetic core and surge arrester nonlinear characteristics were estimated from laboratory measurements as well. The model is used in connection with the electromagnetic transients program (EMTP) to predict the CCVT performance when it is submitted to transient overvoltages, as are the cases of voltages due to the ferroresonance phenomenon and circuit breaker switching. The difference between simulated and measured results is fairly small. Simulations had shown that transient overvoltages produced inside the CCVT, when a short circuit is cleared at the CCVT secondary side, are effectively damped out by the ferroresonance suppression circuit and the protection circuit. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 134
页数:10
相关论文
共 14 条
[1]  
[Anonymous], 1987, ATP ALT TRANS PROGR
[2]  
FERNANDES D, 2003, THESIS FEDERAL U CAM
[3]  
FERNANDES D, 2005, 2005 INT C POW SYST
[4]  
*IEEE, 1981, IEEE T POWER APPARAT, V100, P4033
[5]  
*IEEE, 1989, C6211989 ANSIIEEE
[6]   Digital time-domain investigation of transient behavior of coupling capacitor voltage transformer [J].
Iravani, MR ;
Wang, X ;
Polishchuk, I ;
Ribeiro, J ;
Sarshar, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (02) :622-629
[7]   DIGITAL MODELS OF COUPLING CAPACITOR VOLTAGE TRANSFORMERS FOR PROTECTIVE RELAY TRANSIENT STUDIES [J].
KEZUNOVIC, M ;
KOJOVIC, L ;
SKENDZIC, V ;
FROMEN, CW ;
SEVCIK, DR ;
NILSSON, SL .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) :1927-1935
[8]   A NEW METHOD FOR THE CCVT PERFORMANCE ANALYSIS USING FIELD-MEASUREMENTS, SIGNAL-PROCESSING AND EMTP MODELING [J].
KOJOVIC, L ;
KEZUNOVIC, M ;
FROMEN, CW ;
SKENDZIC, V ;
SEVCIK, DR .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (04) :1907-1915
[9]  
KOJOVIC L, 1992, 1992 INT C COMP APPL
[10]   IMPROVED SIMULATION-MODELS FOR CURRENT AND VOLTAGE TRANSFORMERS IN RELAY STUDIES [J].
LUCAS, JR ;
MCLAREN, PG ;
KEERTHIPALA, WWL ;
JAYASINGHE, RP .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) :152-159