Towards large-area photon-counting detectors for spectral x-ray imaging

被引:2
|
作者
Thuering, Thomas [1 ]
Gkoumas, Spyridon [1 ]
Zambon, Pietro [1 ]
Trueb, Peter [1 ]
Rissi, Michael [1 ]
Di Prima, Flavio [1 ]
Donath, Tilman [1 ]
Sawall, Stefan [2 ]
Amato, Carlo [2 ]
Kachelriess, Marc [2 ]
Broennimann, Christian [1 ]
机构
[1] DECTRIS Ltd, Tafernweg 1, CH-5405 Baden, Switzerland
[2] German Canc Res Ctr, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
来源
MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING | 2019年 / 10948卷
关键词
Photon-counting detectors; CdTe; spectral X-ray imaging; large-area detector; material decomposition;
D O I
10.1117/12.2507190
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photon-counting detector technology using directly converting high-Z sensor materials has recently gained popularity in medical imaging due to its capability to reduce patient dose, increase spatial resolution and provide single shot multi energy information. However, in medical imaging applications, the novel technology is not yet widely used due to technical challenges in manufacturing gap-less detectors with large areas. Here, a nearly gap-less, large-area, multi-energy photon counting detector prototype is presented which was built with existing ASIC and sensor technology. It features an active area of 8x8 cm(2), a 1 mm thick cadmium telluride (CdTe) sensor, four independent energy thresholds and a pixel size of 150 lam. Single and multi-threshold imaging performance of the detector is evaluated by assessing various metrics relevant for conventional (polychromatic) and spectral imaging applications. A high detective quantum efficiency (DQE(0)=0.97), a low dark noise threshold (6.5 keV) and a high count rate capability (up to 3x10(8) counts/s/mm(2)) indicate that the detector is optimally suited for conventional medical X-ray imaging, especially for low dose applications. Spectral performance was assessed by acquiring spectra from fluorescence samples, and the results show a high accuracy of energy peak positions (< 1 keV), precise energy resolution (within a few keV) and decent peak-to-background ratios. Spectral absorption measurements of water and iodinated contrast agent, as well as spectral X-ray radiographs of a human hand phantom, decomposed into bone and soft tissue basis images, demonstrate the multi-energy performance of the detector.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Spectral Distortion Correction for Photon-Counting X-Ray Detectors
    Ding, H.
    Molloi, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3989 - 3989
  • [2] Large-area pixellated photon counting X-ray imaging system
    Iles, G
    Mathieson, K
    Murray, P
    Passmore, S
    Prydderch, M
    Seller, P
    Thomas, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 427 - 430
  • [3] Method for the Correction of Spectral Distortions in X-Ray Photon-Counting Detectors
    Jumanazarov, Doniyor
    Atamurotov, Farruh
    Xudoynazarov, Egambergan
    Matyokubov, Khikmatjon
    Saparbaev, Rakhmon
    Abdikarimov, Xidoyat
    Olsen, Ulrik L.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [4] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [5] Spectral computed tomography in the age of photon-counting X-ray detectors
    Rotkopf, Lukas T.
    Wehrse, Eckhard
    Froelich, Matthias F.
    RADIOLOGIE, 2022, 62 (06): : 504 - 510
  • [6] X-ray imaging with sub-micron resolution using large-area photon counting detectors Timepix
    Dudak, J.
    Karch, J.
    Holcova, K.
    Zemlicka, J.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [7] Energy-sensitive scatter estimation and correction for spectral x-ray imaging with photon-counting detectors
    Lewis, Cale E.
    Das, Mini
    JOURNAL OF INSTRUMENTATION, 2022, 17 (12)
  • [8] Development of a pixel readout ASIC for CZT detectors for spectral X-ray photon-counting imaging applications
    Wang, X.
    Deng, Z.
    Liu, W.
    Liu, Y.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01):
  • [9] Noise in energy-discriminating photon-counting x-ray imaging detectors
    Tanguay, Jesse
    Kim, Ho Kyung
    Cunningham, Ian A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [10] PIXIE III: a very large area photon-counting CMOS pixel ASIC for sharp X-ray spectral imaging
    Bellazzini, R.
    Brez, A.
    Spandre, G.
    Minuti, M.
    Pinchera, M.
    Delogu, P.
    de Ruvo, P. L.
    Vincenzi, A.
    JOURNAL OF INSTRUMENTATION, 2015, 10