Inductively Coupled Plasma Zoom-Time-of-Flight Mass Spectrometry

被引:3
|
作者
Dennis, Elise A. [1 ]
Ray, Steven J. [1 ]
Enke, Christie G. [2 ]
Hieftje, Gary M. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] Univ New Mexico, Dept Chem & Biol Chem, Albuquerque, NM 87131 USA
关键词
Inductively coupled plasma; Zoom-TOF; Time-of-Flight; Mass spectrometry; CONSTANT-MOMENTUM-ACCELERATION; LASER-ABLATION; ELECTROTHERMAL VAPORIZATION; SAMPLE INTRODUCTION; PERFORMANCE; RESOLUTION; ENERGY; SPECIATION; CYTOMETRY; DETECTOR;
D O I
10.1007/s13361-015-1309-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A zoom-time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom-time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7x over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time-compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3-5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 50 条
  • [1] Distance-of-Flight Mass Spectrometry with IonCCD Detection and an Inductively Coupled Plasma Source
    Dennis, Elise A.
    Ray, Steven J.
    Enke, Christie G.
    Gundlach-Graham, Alexander W.
    Barinaga, Charles J.
    Koppenaal, David W.
    Hieftje, Gary M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (03) : 371 - 379
  • [2] Zoom-TOFMS: addition of a constant-momentum-acceleration "zoom" mode to time-of-flight mass spectrometry
    Dennis, Elise A.
    Gundlach-Graham, Alexander W.
    Ray, Steven J.
    Enke, Christie G.
    Barinaga, Charles J.
    Koppenaal, David W.
    Hieftje, Gary M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7419 - 7430
  • [3] Capabilities of laser ablation inductively coupled plasma time-of-flight mass spectrometry
    Burger, Marcel
    Schwarz, Gunnar
    Gundlach-Graham, Alexander
    Kaser, Debora
    Hattendorf, Bodo
    Guenther, Detlef
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (10) : 1946 - 1959
  • [4] Evaluation and correction of isotope ratio inaccuracy on inductively coupled plasma time-of-flight mass spectrometry
    Rowland, Adam
    Holcombe, James A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (01) : 35 - 41
  • [5] Laser ablation-inductively coupled plasma mass spectrometry with a time-of-flight mass analyser
    Mahoney, PP
    Li, GQ
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (06) : 401 - 405
  • [6] Inductively coupled plasma mass spectrometry: recent trends and developments
    Engelhard, Carsten
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (01) : 213 - 219
  • [7] Inductively Coupled Plasma Mass Spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 4786 - 4810
  • [8] TOFHunter-unlocking rapid untargeted screening of inductively coupled plasma-time-of-flight-mass spectrometry data
    Andrews, Hunter B.
    Hendriks, Lyndsey
    Irvine, Sawyer B.
    Dunlap, Daniel R.
    Manard, Benjamin T.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (03) : 910 - 920
  • [9] Diode Laser Thermal Vaporization Inductively Coupled Plasma Mass Spectrometry
    Foltynova, Pavla
    Kanicky, Viktor
    Preisler, Jan
    ANALYTICAL CHEMISTRY, 2012, 84 (05) : 2268 - 2274
  • [10] Inductively coupled plasma mass spectrometry-based immunoassay: A review
    Liu, Rui
    Wu, Peng
    Yang, Lu
    Hou, Xiandeng
    Lv, Yi
    MASS SPECTROMETRY REVIEWS, 2014, 33 (05) : 373 - 393