A reliable LC-MS/MS method for the quantification of natural amino acids in mouse plasma: Method validation and application to a study on amino acid dynamics during hepatocellular carcinoma progression

被引:46
作者
Liu, Zhenzhen [1 ,2 ]
Tu, Mei-Juan [2 ]
Zhang, Chao [2 ]
Jilek, Joseph L. [2 ]
Zhang, Qian-Yu [2 ]
Yu, Ai-Ming [2 ]
机构
[1] Yangtze Univ, Hlth Sci Ctr, Dept Med Funct, Jingzhou 434000, Hubei, Peoples R China
[2] Univ Calif Davis, Sch Med, Dept Biochem & Mol Med, Sacramento, CA 95817 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2019年 / 1124卷
基金
美国国家卫生研究院;
关键词
LC-MS/MS; Amino acids; Biomarker; Hepatocellular carcinoma; Tumor progression; LIQUID-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; QUANTITATIVE-ANALYSIS; METABOLISM PATHWAY; HUMAN SERUM; METABOLOMICS; PERFORMANCE; NEUROTRANSMITTERS; DERIVATIZATION; RECURRENCE;
D O I
10.1016/j.jchromb.2019.05.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and fast LC-MS/MS method was developed and validated for simultaneous quantification of 20 proteinogenic L-amino acids (AAs) in a small volume (5 mu L) of mouse plasma. Chromatographic separation was achieved on an Intrada Amino Acid column within 13 mM via gradient elution with an aqueous solution containing 100 mM ammonium formate and an organic mobile phase containing acetonitrile, water and formic acid (v:v:v = 95:5:0.3), at the flow rate of 0.6 mL/min. Individual AAs and corresponding stable-isotope-labeled AAs internal standards were analyzed by multiple reaction monitoring (MRM) in positive ion mode under optimized conditions. Method validation consisted of linearity, sensitivity, accuracy and precision, recovery, matrix effect, and stability, and the results demonstrated this LC-MS/MS method as a specific, accurate, and reliable assay. This LC-MS/MS method was thus utilized to compare the dynamics of individual plasma AAs between healthy and orthotopic hepatocellular carcinoma (HCC) xenograft mice housed under identical conditions. Our results revealed that, 5 weeks after HCC tumor progression, plasma L-arginine concentrations were significantly decreased in HCC mice while L-alanine and L-threonine levels were sharply increased. These findings support the utilities of this LC-MS/MS method and the promise of specific AAs as possible biomarkers for HCC.
引用
收藏
页码:72 / 81
页数:10
相关论文
共 53 条
  • [51] Analysis of Urinary Metabolic Signatures of Early Hepatocellular Carcinoma Recurrence after Surgical Removal Using Gas Chromatography-Mass Spectrometry
    Ye, Guozhu
    Zhu, Bin
    Yao, Zhenzhen
    Yin, Peiyuan
    Lu, Xin
    Kong, Hongwei
    Fan, Fei
    Jiao, Binghua
    Xu, Guowang
    [J]. JOURNAL OF PROTEOME RESEARCH, 2012, 11 (08) : 4361 - 4372
  • [52] Validation of an analytical method for human plasma free amino acids by high-performance liquid chromatography ionization mass spectrometry using automated precolumn derivatization
    Yoshida, Hiroo
    Kondo, Kazuhiro
    Yamamoto, Hiroyuki
    Kageyama, Naoko
    Ozawa, Shin-ichi
    Shimbo, Kazutaka
    Muramatsu, Takahiko
    Imaizumi, Akira
    Mizukoshi, Toshimi
    Masuda, Junichi
    Nakayama, Daisuke
    Hayakawa, Yoshihiro
    Watanabe, Kyoko
    Mukaibatake, Kazuo
    Miyano, Hiroshi
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 998 : 88 - 96
  • [53] Metabolic profiling study of early and late recurrence of hepatocellular carcinoma based on liquid chromatography-mass spectrometry
    Zhou, Lina
    Liao, Yuan
    Yin, Peiyuan
    Zeng, Zhongda
    Li, Jia
    Lu, Xin
    Zheng, Limin
    Xu, Guowang
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 966 : 163 - 170