Off-design performance analysis of a turbocharged solid oxide fuel cell system

被引:14
|
作者
Mantelli, L. [1 ]
Ferrari, M. L. [1 ]
Magistri, L. [1 ]
机构
[1] Univ Genoa, Thermochem Power Grp TPG, Via Montallegro 1, I-16145 Genoa, Italy
关键词
Pressurized SOFC system; Fuel cell; Turbocharger; Off-design performance analysis; Biofuel;
D O I
10.1016/j.applthermaleng.2020.116134
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of this study is to analyse the off-design performance of an innovative turbocharged solid oxide fuel cell system, fed by biogas and designed to generate 30 kW during nominal operating conditions. The layout of such a plant combines the high efficiencies of the solid oxide fuel cell with a reduced-cost option for fuel cell pressurization: fuel cells are usually pressurized by a micro gas turbine, but the alternative use of a turbocharger, a mass-produced component widely used in the automotive field, could reduce significantly the capital cost of the system. This kind of layout has been rarely investigated in literature, and a detailed performance analysis of a turbocharged SOFC system would be a valuable source of information for both academia and industry. To perform this analysis, a steady-state model has been created using a modular tool developed in Matlab (R)-Simulink (R) that includes off-design models of the system components. The model has been used to compare different control strategies. The most suitable control strategy, based on wastegate and cold bypass valves, was adopted, obtaining compliance with the operative constraints and high system efficiency. Afterward, the system steady-state operation was simulated for various electric power loads and ambient temperatures. The performance analysis focused on the effect of these two variables on the system behaviour and has provided insight on the influence on the most significant system outputs, including global efficiency, temperatures and pressures. A system efficiency increase was observed at part load, with values growing from 50.8% to 57.3%. Higher values of ambient temperature resulted in a more significant pressurization of the fuel cell, affecting positively the system efficiency: from 50.5% at 0 degrees C to 51.0% at 30 degrees C. Great attention was paid to the system constraints, to verify that the plant could operate properly in all the considered conditions. The proposed control strategy was tested and proved to be effective at achieving this objective.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Prediction of on-design and off-design performance for a solid oxide fuel cell power module
    Bessette, NF
    Wepfer, WJ
    ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (03) : 281 - 293
  • [2] Off-design operation of a proton conducting solid oxide fuel cell
    Milewski, Jaroslaw
    Szczesniak, Arkadiusz
    APPLIED THERMAL ENGINEERING, 2022, 212
  • [3] Off-design performance analysis for an integrated system of solid oxide fuel cell and supercritical carbon dioxide Brayton cycle with CO2 capture
    Liu, Zekun
    Wang, Yutian
    Xie, Meina
    He, Xianya
    Zhang, Wenxian
    Xie, Shan
    Zhao, Yingru
    ENERGY CONVERSION AND MANAGEMENT, 2023, 292
  • [4] Off-design performance analysis of a hybrid system based on an existing molten fuel cell stack
    Bedont, P
    Grillo, O
    Massardo, AF
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2003, 125 (04): : 986 - 993
  • [5] Off-design performance analysis of a solid-oxide fuel celugas turbine hybrid for auxiliary aerospace power
    Freeh, Joshua E.
    Steffen, Christopher J., Jr.
    Larosiliere, Louis M.
    Proceedings of the 3rd International Conference on Fuel Cell Science, Engineering, and Technology, 2005, : 265 - 272
  • [6] Dynamics and control of a turbocharged solid oxide fuel cell system
    Mantelli, L.
    Ferrari, M. L.
    Traverso, A.
    APPLIED THERMAL ENGINEERING, 2021, 191
  • [8] Design and performance analysis of a coupled burner for the Solid Oxide Fuel Cell system
    Yang, Baogang
    Hao, Xianying
    Shen, Xuesong
    Shi, Wangying
    Xie, Yitong
    Li, Liang
    ENERGY CONVERSION AND MANAGEMENT, 2024, 322
  • [9] Design and off-design analysis of a MW hybrid system based on rolls-royce integrated planar solid oxide fuel cells
    Magistri, Loredana
    Bozzolo, Michele
    Tarnowski, Olivier
    Agnew, Gerry
    Massardo, Aristide F.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2007, 129 (03): : 792 - 797
  • [10] Off-design analysis of a micro-CHP unit with solid oxide fuel cells fed by DME
    Kupecki, Jakub