Ion-exclusion controlled size-exclusion chromatography of methacrylic acid-methyl methacrylate copolymers

被引:10
|
作者
Porsch, B [1 ]
Hillang, I
Karlsson, A
Sundelöf, LO
机构
[1] Acad Sci Czech Republ, Inst Macromol Chem, CR-16206 Prague 6, Czech Republic
[2] Pharmacia & Upjohn AB, Analyt Chem R&D, S-75182 Uppsala, Sweden
[3] BMC, Phys Pharmaceut Chem, S-75123 Uppsala, Sweden
关键词
detection; LC; pharmaceutical analysis; methacrylic acid-methyl methacrylate polymers; Eudragit polymers; polymers;
D O I
10.1016/S0021-9673(99)01262-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Controlled ion-exclusion allows compensation of hydrophobic adsorption in size-exclusion chromatography of negatively charged methacrylic acid-methyl methacrylate (Eudragit) polymers using methanol as a mobile phase, Properly selected low-ionic-strength conditions below 5 mM LiCl provide correct separation in the size-exclusion mode. Possible disturbing effects, mainly related to light scattering, under low-salt conditions are discussed and shown to be negligible if on-line concentration-light scattering detection is used. The absence of these disturbances is checked by a comparison of experiments performed in methanol containing 1.25 mM and 2.5 mM LiCl. Molecular mass averages and distributions identical within the experimental error are obtained. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 50 条
  • [31] Sizing Up Size-Exclusion Chromatography
    Matheson, Alasdair
    Striegel, Andre
    LC GC EUROPE, 2019, 32 (08) : 420 - 423
  • [32] Poppe plots for size-exclusion chromatography
    Popovici, ST
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1073 (1-2) : 87 - 91
  • [33] Size-exclusion chromatography with a multipore column
    Nagata, M
    BUNSEKI KAGAKU, 1998, 47 (11) : 895 - 896
  • [34] Rapid size-exclusion chromatography of proteoglycans
    Johnson, PY
    Blake, DA
    JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (01): : 27 - 33
  • [35] Size-exclusion chromatography of perfluorosulfonated ionomers
    Mourey, T. H.
    Slater, L. A.
    Galipo, R. C.
    Koestner, R. J.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (34) : 5801 - 5809
  • [36] Accuracy Validation of Size-Exclusion Chromatography
    Barth, Howard G.
    LC GC NORTH AMERICA, 2018, 36 (02) : 142 - 145
  • [37] SIZE-EXCLUSION CHROMATOGRAPHY OF PROTEINS AND PEPTIDES
    ANTLE, PE
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1985, 62 (04) : 660 - 660
  • [38] ONLINE PROCESS SIZE-EXCLUSION CHROMATOGRAPHY
    MOWERY, RA
    FULLER, EN
    BADE, RK
    AMERICAN LABORATORY, 1982, 14 (05) : 61 - &
  • [39] SIZE-EXCLUSION CHROMATOGRAPHY IN AN ANALYTICAL PERSPECTIVE
    HAGEL, L
    JOURNAL OF CHROMATOGRAPHY, 1993, 648 (01): : 19 - 25
  • [40] Controlled Synthesis of Methacrylic Acid-Methyl Acrylate Copolymers and Their Properties at Various Interfaces
    Zamyshlyayeva, O. G.
    Ionychev, B. N.
    Frolova, A. I.
    Baten'kin, M. A.
    Simonova, M. A.
    Kopylova, N. A.
    Zaitsev, S. D.
    Semchikov, Yu. D.
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2019, 92 (06) : 775 - 786