A Geometric Model to Determine Patient-Specific Cup Anteversion Based on Pelvic Motion in Total Hip Arthroplasty

被引:6
|
作者
Sutter, E. Grant [1 ]
Wellman, Samuel S. [1 ]
Bolognesi, Michael P. [1 ]
Seyler, Thorsten M. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Orthopaed Surg, Durham, NC 27708 USA
关键词
LUMBAR SPINE DISEASE; ACETABULAR COMPONENT; SAFE ZONE; DEFORMITY; ORIENTATION; DISLOCATION; REVISION; RISK; TILT; EPIDEMIOLOGY;
D O I
10.1155/2019/4780280
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction. Cup position is critical to stability in total hip arthroplasty and is affected by pelvis motion during positions of daily life. The purpose of this study was to explicitly define the relationship between sagittal pelvic motion and resultant cup functional anteversion and create a tool to guide the surgeon to a patient-specific intra-operative anteversion. Materials and Methods. 10,560 combinations of inclination, anteversion, and pelvic tilt were generated using a geometric model. Resultant functional anteversion was calculated for each iteration and variables were correlated. An electronic mobile tool was created that compares inputted patient-specific values to population-based averages to determine pelvic positions and dynamics that may lead to instability. Results. A third-degree polynomial equation was used to describe the relationship between variables. The freely downloadable mobile tool uses input from pre-operative plain radiographic measurements to provide the surgeon a quantitative correction to intra-operative cup anteversion based on differences in functional anteversion compared to population-based averages. Conclusion. This study provides a geometric relationship between planned cup position, pelvic position and motion, and the resultant functional anteversion. This mathematical model was applied to an electronic tool that seeks to determine an individualized intra-operative cup anteversion based on measured patient-specific pelvic dynamics.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Real-time motion analysis for patients after total hip arthroplasty by using 4-dimensional patient-specific model
    Otake, Y
    Suzuki, N
    Hattori, A
    Miki, H
    Yamamura, M
    Sugano, N
    Yonenobu, K
    Ochi, T
    CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 696 - 701
  • [32] Differences in range of motion with the same combined anteversion after total hip arthroplasty
    Takaaki Ohmori
    Tamon Kabata
    Yoshitomo Kajino
    Tadashi Taga
    Kazuhiro Hasegawa
    Daisuke Inoue
    Takashi Yamamoto
    Tomoharu Takagi
    Junya Yoshitani
    Takuro Ueno
    Hiroyuki Tsuchiya
    International Orthopaedics, 2018, 42 : 1021 - 1028
  • [33] The effect of cup medialization and lateralization on hip range of motion in total hip arthroplasty
    Shoji, Takeshi
    Yamasaki, Takuma
    Izumi, Soutarou
    Kenji, Mifuji
    Sawa, Mikiya
    Yasunaga, Yuji
    Adachi, Nobuo
    CLINICAL BIOMECHANICS, 2018, 57 : 121 - 128
  • [34] A new radiographic acetabular cup anteversion measurement method in total hip arthroplasty: a clinical study
    Saka, G.
    Altun, G.
    Burc, H.
    Aydogan, M.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (04): : 813 - 818
  • [35] Differences in range of motion with the same combined anteversion after total hip arthroplasty
    Ohmori, Takaaki
    Kabata, Tamon
    Kajino, Yoshitomo
    Taga, Tadashi
    Hasegawa, Kazuhiro
    Inoue, Daisuke
    Yamamoto, Takashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueno, Takuro
    Tsuchiya, Hiroyuki
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (05) : 1021 - 1028
  • [36] Evaluation of Tilt-correction of Anteversion on Anteroposterior Pelvic Radiographs in Total Hip Arthroplasty
    Muir, Jeffrey M.
    Vincent, John
    Schipper, Joseph
    Govindarajan, Meinusha
    Paprosky, Wayne G.
    CUREUS, 2018, 10 (05):
  • [37] Cup aligmuent error model for total hip arthroplasty
    Wolf, A
    DiGioia, AM
    Mor, AB
    Jaramaz, B
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) : 132 - 137
  • [38] Patient-specific instrumentation in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Martinez-Martinez, Francisco
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (07) : 555 - 567
  • [39] Influence of the X-ray technique on evaluation of cup anteversion after total hip arthroplasty
    Marx, A.
    Pfoertner, J.
    von Knoch, M.
    Wiese, M.
    Loeer, F.
    Saxler, G.
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2006, 144 (04): : 394 - 399
  • [40] Patient-specific Instruments for Total Knee Arthroplasty
    Lachiewicz, Paul F.
    Henderson, Robert A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2013, 21 (09) : 513 - 518