One lung ventilation: double-lumen tube with vs. without carinal hook

被引:0
作者
Potocnik, Iztok [1 ]
Andjelkovic, Lea [1 ]
Markovic-Bozic, Jasmina [1 ]
机构
[1] Univ Med Ctr Ljubljana, Clin Dept Anaesthesiol & Surg Intens Therapy, Zaloska 2, Ljubljana, Slovenia
关键词
double-lumen tube; carinal hook; pulmonary surgery; BRONCHIAL BLOCKERS; THORACIC-SURGERY; EFFICACY; RUPTURE; TRIAL;
D O I
10.22514/SV141.052018.4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. One lung ventilation (OLV) has become a standard procedure for the vast majority of interventions in pulmonary surgery. The most commonly used are left sided double-lumen tubes (DLTs) which are placed into the left main bronchus and the right or left lung can be isolated. The aim of our study was to compare DLTs with and without a hook. Materials and methods. Fifty-four patients undergoing lung resection were included in the randomized, controlled, single-blinded study. Recruited patients were randomly allocated to each group (hook/without hook). Demographic data, procedural data, type of tube used, and difficult intubation criteria were recorded. Complications, according to intubation and position of the tube, were also recorded. After the operation, we aske patients about a sore throat, hoarseness, haemoptysis and their satisfaction with the procedure. Results. Baseline characteristics were well balanced between groups. Time to place DLT was shorter in the group without a hook (47.7 +/- 45.5 vs 15.8 +/- 15.1s; P=0.01). The incidence of adequate positioning at the first attempt was higher in the group with a hook and the repositioning rate was higher in the group without a hook (22.22 vs 59.25%; P=0.004). Patients in both groups suffered similar incidences of hoarseness, sore throat or postoperative haemoptysis (5/5/1 vs 3/3/0; P =0.44). Patient satisfaction was higher in the group without a hook (31.85% vs 34.81%; 0.03). Conclusion. The study showed the advantage of DLTs without a hook in comparison with DLTs with a hook. In our institution we decided to use DLTs without a hook, with fiberoptic control.
引用
收藏
页码:27 / 29
页数:3
相关论文
共 17 条
[1]   Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy [J].
Bauer, C ;
Winter, C ;
Hentz, JG ;
Ducrocq, X ;
Steib, A ;
Dupeyron, JP .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) :250-254
[2]  
Brodsky Jay B, 2004, Curr Opin Anaesthesiol, V17, P7, DOI 10.1097/00001503-200402000-00003
[3]  
Campos J H, 2001, Anesthesiol Clin North Am, V19, P455, DOI 10.1016/S0889-8537(05)70243-1
[4]   Devices for lung isolation used by anesthesiologists with limited thoracic experience -: Comparison of double-lumen endotracheal tube, Univent® torque control blocker, and Arndt wire-guided endobronchial Blocker® [J].
Campos, JH ;
Hallam, EA ;
Van Natta, T ;
Kernstine, KH .
ANESTHESIOLOGY, 2006, 104 (02) :261-266
[5]  
CARLENS E, 1949, J THORAC SURG, V18, P742
[6]   A Comparison of the Efficacy and Adverse Effects of Double-Lumen Endobronchial Tubes and Bronchial Blockers in Thoracic Surgery: A Systematic Review and Meta-analysis of Randomized Controlled Trials [J].
Clayton-Smith, Ana ;
Bennett, Kyle ;
Alston, Robin Peter ;
Adams, George ;
Brown, Greg ;
Hawthorne, Timothy ;
Hu, May ;
Sinclair, Angus ;
Tan, Jay .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (04) :955-966
[7]  
Cohen Edmond, 2004, Curr Opin Anaesthesiol, V17, P1, DOI 10.1097/00001503-200402000-00002
[8]   Left double-lumen tube with or without a carinal hook A randomised controlled trial [J].
Dumans-Nizard, Virginie ;
Parquin, Jean-Francois ;
Moyer, Jean-Denis ;
Dreyfus, Jean Francois ;
Fischler, Marc ;
Le Guen, Morgan .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (06) :418-424
[9]   Airway rupture from double-lumen tubes [J].
Fitzmaurice, BG ;
Brodsky, JB .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (03) :322-329
[10]   Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia - A prospective study [J].
Klein, U ;
Karzai, W ;
Bloos, F ;
Wohlfarth, M ;
Gottschall, R ;
Fritz, H ;
Gugel, M ;
Seifert, A .
ANESTHESIOLOGY, 1998, 88 (02) :346-350