Analysis of complex protein mixtures with improved sequence coverage using (CE-MS/MS)n

被引:41
作者
Garza, Selynda [1 ]
Moini, Mehdi [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
D O I
10.1021/ac0612269
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)(n), which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)(n) can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)(n) is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes similar to 10 min; therefore, several subanalyses can be performed in similar to 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)(n) using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)(n) is performed by scanning a narrow mass range (every similar to 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of similar to 26 000 (standard I), a six-protein mixture with an average MW similar to 49 000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In similar to 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respctively.
引用
收藏
页码:7309 / 7316
页数:8
相关论文
共 50 条
  • [41] Analysis of iron-phytosiderophore complexes in soil related samples: LC-ESI-MS/MS versus CE-MS
    Dell'mour, Madeleine
    Schenkeveld, Walter
    Oburger, Eva
    Fischer, Lisa
    Kraemer, Stephan
    Puschenreiter, Markus
    Laemmerhofer, Michael
    Koellensperger, Gunda
    Hann, Stephan
    ELECTROPHORESIS, 2012, 33 (04) : 726 - 733
  • [42] Sensitive CE-MS analysis of potentially genotoxic alkylation compounds using derivatization and electrokinetic injection
    van Wijk, A. M.
    Niederlander, H. A. G.
    van Ogten, M. D.
    de Jong, G. J.
    ANALYTICA CHIMICA ACTA, 2015, 874 : 75 - 83
  • [43] Intelligent MS/MS acquisition results in higher sequence coverage and more confident protein IDs from complex samples
    Meza, J.
    MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (08) : 43 - 43
  • [44] Analysis of aristolochic acids by CE-MS with carboxymethyl chitosan-coated capillary
    Fu, Xiaofang
    Liu, Yi
    Li, Wei
    Pang, Nannan
    Nie, Honggang
    Liu, Huwei
    Cai, Zongwei
    ELECTROPHORESIS, 2009, 30 (10) : 1783 - 1789
  • [45] CE-MS analysis of the human urinary proteome for biomarker discovery and disease diagnostics
    Coon, Joshua J.
    Zuerbig, Petra
    Dakna, Mohammed
    Dominicza, Anna F.
    Decramer, Stephane
    Fliser, Danilo
    Frommberger, Moritz
    Golovko, Igor
    Good, David M.
    Herget-Rosenthal, Stefan
    Jankowski, Joachim
    Julian, Bruce A.
    Kellmann, Markus
    Kolch, Walter
    Massy, Ziad
    Novak, Jan
    Rossing, Kasper
    Schanstra, Joost P.
    Schiffer, Eric
    Theodorescu, Dan
    Vanholder, Raymond
    Weissinger, Eva M.
    Mischak, Harald
    Schmitt-Kopplin, Philippe
    PROTEOMICS CLINICAL APPLICATIONS, 2008, 2 (7-8) : 964 - 973
  • [46] Prediction of the amino acid composition of small peptides contained in a plant protein hydrolysate by LC-MS and CE-MS
    Tessier, B
    Schweizer, M
    Fournier, F
    Framboisier, X
    Chevalot, I
    Vanderesse, R
    Harscoat, C
    Marc, I
    FOOD RESEARCH INTERNATIONAL, 2005, 38 (05) : 577 - 584
  • [47] Intact and subunit-specific analysis of bispecific antibodies by sheathless CE-MS
    Gstottner, Christoph
    Nicolardi, Simone
    Haberger, Markus
    Reusch, Dietmar
    Wuhrer, Manfred
    Dominguez-Vega, Elena
    ANALYTICA CHIMICA ACTA, 2020, 1134 (1134) : 18 - 27
  • [48] CE-MS: A useful alternative to LC-MS for the analysis of nonvolatile flavour molecules and metabolites in blue cheese
    Bull, Stephanie
    Woodward, Susanne
    Ross, Gordon
    Lee, John
    Marshall, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246
  • [49] Simplified 2-D CE-MS mapping: Analysis of proteolytic digests
    Erny, Guillaume L.
    Cifuentes, Alejandro
    ELECTROPHORESIS, 2007, 28 (09) : 1335 - 1344
  • [50] Identifying bacterial species using CE-MS and SEQUEST with an empirical scoring function
    Hu, Anren
    Lo, Alan A. -L.
    Chen, Cheng-Tung
    Lin, Kuo-Chih
    Ho, Yen-Peng
    ELECTROPHORESIS, 2007, 28 (09) : 1387 - 1392