Smartphone technology: a reliable and valid measure of knee movement in knee replacement

被引:22
作者
Castle, Hannah [1 ]
Kozak, Kon [1 ]
Sidhu, Aman [2 ]
Khan, Riaz J. K. [1 ,2 ,3 ,4 ]
Haebich, Samantha [2 ]
Bowden, Vanessa [3 ]
Fick, Daniel P. [1 ,2 ,3 ]
Goonatillake, Hari [1 ]
机构
[1] Hollywood Private Hosp, Nedlands, WA, Australia
[2] Hollywood Med Ctr, Joint Studio, Nedlands, WA, Australia
[3] Univ Western Australia, Sch Med, Crawley, England
[4] Univ Notre Dame, Sch Med, Fremantle, WA, Australia
关键词
knee arthroplasty; range of motion; reliability; smartphone; validity; RELIABILITY; ANGLE; GONIOMETER; ARTHROPLASTY; RANGE; APP;
D O I
10.1097/MRR.0000000000000276
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Knee range of motion (ROM) following a knee arthroplasty is an important clinical outcome that directly relates to the patient's physical function. Smartphone technology has led to the creation of applications that can measure ROM. The aim was to determine the concurrent reliability and validity of the photo-based application Dr Goniometer' (DrG) compared with a universal goniometer performed by a clinician. A smartphone camera was used to take photographs of the knee in full flexion and full extension, and the images were sent by participants to a study phone. Participants then rated the ease of participation. To assess validity, the patient's knee was measured by a clinician using a goniometer. To examine reliability, four clinicians assessed each image using DrG on four separate occasions spaced 1 week apart. A total of 60 images of knee ROM for 30 unicondylar or total knee arthroplasty were assessed. The goniometer and DrG showed strong correlations for flexion (r=0.94) and extension (r=0.90). DrG showed good intrarater reliability and excellent inter-rater reliability for flexion (intraclass correlation coefficient=0.990 and 0.990) and good reliability for extension (intraclass correlation coefficient=0.897 and 0.899). All participants found the process easy. DrG was proven to be a valid and reliable tool in measuring knee ROM following arthroplasty. Smartphone technology, in conjunction with patient-reported outcomes, offers an accurate and practical way to remotely monitor patients. Benefit may be found in differentiating those who need face-to-face clinical consult to those who do not.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 19 条
[1]  
Australian Orthopaedic Association, 2015, NAT JOINT REPL REG A
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Procedural considerations for photographic-based joint angle measurements [J].
Dunlevy, Colin ;
Cooney, Marese ;
Gormely, John .
PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2005, 10 (04) :190-200
[4]  
Farahini H, 2012, IRAN RED CRESCENT ME, V14, P417
[5]   Reliability of a smartphone-based goniometer for knee joint goniometry [J].
Ferriero, Giorgio ;
Vercelli, Stefano ;
Sartorio, Francesco ;
Munoz Lasa, Susana ;
Ilieva, Elena ;
Brigatti, Elisa ;
Ruella, Carolina ;
Foti, Calogero .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2013, 36 (02) :146-151
[6]   CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[7]   Clinical, Objective, and Functional Outcomes of Manipulation Under Anesthesia to Treat Knee Stiffness Following Total Knee Arthroplasty [J].
Issa, Kimona ;
Kapadia, Bhaveen H. ;
Kester, Mark ;
Khanuja, Harpal S. ;
Delanois, Ronald E. ;
Mont, Michael A. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (03) :548-552
[8]   Measurement of the Knee Flexion Angle With a Smartphone-Application is Precise and Accurate [J].
Jenny, Jean-Yves .
JOURNAL OF ARTHROPLASTY, 2013, 28 (05) :784-787
[9]  
Jenny JY, 2015, KNEE SURG SPORT TR A, P1
[10]   Computerized biofeedback knee goniometer acceptance and effect on exercise behavior in post-total knee arthroplasty rehabilitation [J].
Kuiken, TA ;
Amir, H ;
Scheidt, RA .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (06) :1026-1030