Derivation of aortic distensibility and pulse wave velocity by image registration with a physics-based regularisation term

被引:4
作者
Barber, David C. [1 ]
Valverde, Isra [2 ]
Shi, Yubing [1 ]
Brown, Alistair [1 ]
Beerbaum, Philipp [3 ]
Hose, D. Rodney [1 ]
机构
[1] Univ Sheffield, Dept Cardiovasc Sci, Sheffield, S Yorkshire, England
[2] Kings Coll London, Dept Imaging Sci, London WC2R 2LS, England
[3] Hanover Med Univ, Dept Pediat Cardiol & Pediat Intens Care Med, Childrens Hosp, Hannover, Germany
关键词
FSI; aortic pulse wave velocity; regularisation; image registration; PARAMETER-ESTIMATION; CARDIOVASCULAR RISK; BLOOD-FLOW; MODEL; PRESSURE; ARTERIES;
D O I
10.1002/cnm.2589
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Analysis of the cardiovascular system represents a classical problem in which the solid and fluid phases interact intimately, and so is a rich field of application for state-of-the-art fluid-solid interaction (FSI) analyses. In this paper, we focus on the human aorta. Solution of the full FSI problem requires knowledge of the material properties of the wall and information on vessel support. We show that variation of distensibility along the aorta can be obtained from four-dimensional image data using image registration. If pressure data at one point in the vessel are available, these can be converted to absolute values. Alternatively, values of pulse wave velocity along the vessel can be obtained. The quality of the extracted data is improved by the incorporation into the registration of a regularisation term based on the one-dimensional wave equation. The method has been validated using simulated data. For idealised vessels, the accuracy with which the distensibility and wave velocity can be extracted is high (1%-2%). The method is applied to six clinical datasets from patients with mild coarctation, for which it is shown that wave velocity along the aorta is relatively constant. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:55 / 68
页数:14
相关论文
共 28 条
  • [1] MULTIRESOLUTION ELASTIC MATCHING
    BAJCSY, R
    KOVACIC, S
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1989, 46 (01): : 1 - 21
  • [2] Efficient computational fluid dynamics mesh generation by image registration
    Barber, D. C.
    Oubel, E.
    Frangi, A. F.
    Hose, D. R.
    [J]. MEDICAL IMAGE ANALYSIS, 2007, 11 (06) : 648 - 662
  • [3] Barber DC, 2011, P MED IM UND AN LOND, P275
  • [4] Simulation of blood flow in human aorta with emphasis on outlet boundary conditions
    Benim, A. C.
    Nahavandi, A.
    Assmann, A.
    Schubert, D.
    Feindt, P.
    Suh, S. H.
    [J]. APPLIED MATHEMATICAL MODELLING, 2011, 35 (07) : 3175 - 3188
  • [5] Sequential parameter estimation for fluid-structure problems: Application to hemodynamics
    Bertoglio, Cristobal
    Moireau, Philippe
    Gerbeau, Jean-Frederic
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2012, 28 (04) : 434 - 455
  • [6] Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
    Blacher, J
    Asmar, R
    Djane, S
    London, GM
    Safar, ME
    [J]. HYPERTENSION, 1999, 33 (05) : 1111 - 1117
  • [8] BroNielsen M, 1996, LECT NOTES COMPUT SC, V1131, P267
  • [9] Accuracy vs. computational time: Translating aortic simulations to the clinic
    Brown, Alistair G.
    Shi, Yubing
    Marzo, Alberto
    Staicu, Cristina
    Valverde, Isra
    Beerbaum, Philipp
    Lawford, Patricia V.
    Hose, D. Rodney
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (03) : 516 - 523
  • [10] Chapelle D, 2011, COMPUT FLUID SOLID M, P1, DOI 10.1007/978-3-642-16408-8