Numerical Study on Annular-Mist Flow in V-Cone Meter for Wet Gas Metering

被引:3
作者
Bai, Bofeng [1 ]
He, Denghui [1 ]
Zhou, Rifeng [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
来源
8TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS | 2014年 / 1592卷
关键词
V-Cone meter; Differential pressure; Numerical simulation; Wet gas; Two phase flow; 2-PHASE; MODEL;
D O I
10.1063/1.4872095
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Increasing attention is paid on wet gas flow measurement with V-Cone meter in the production of natural gas. Annular-mist flow is a common flow regime in the wet gas flow metering. Knowledge of the annular-mist flow such as the distributions of the pressure, the droplet and the liquid film in the V-Cone meter is critical to improve the wet gas measurement model. In this paper, a numerical method based on a three-fluid closure model of film, droplet and gas was developed to simulate the annular-mist wet gas flow in the V-Cone meter. The method agreed well with the existing correlation and the relative error of simulation data is less than +/- 2.5%. The distributions of the droplet, liquid film and static pressure in a V-cone meter and the results on different flow conditions were simulated with the present method. The simulations showed that under the adjustment of the V-Cone element, the droplets moved in a straight path close to the wall after the throat section and a liquid jet was formed. It continues through the diffuser and reattaches to the wall. Some droplets will re-coalescence in the downstream of the V-Cone. It was found that little droplet was entrained in the back of the V-Cone, which was benefit for obtaining the low pressure. The results of the liquid film distribution showed that the liquid film thickness on the pipe wall and the cone body was affected by both the geometry of the V-Cone and the area and strength of the low pressure domain. The pressure in the low pressure domain decreased with the liquid and gas velocity increasing, and the gas-to-liquid viscosity ratio had little effects on the pressure distribution. The downstream low pressure port justifiably locates at six or more pipe diameters downstream of the cone back face for the present V-Cone meter.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 19 条
[1]   Modelling of annular flow through pipes and T-junctions [J].
Adechy, D ;
Issa, RI .
COMPUTERS & FLUIDS, 2004, 33 (02) :289-313
[2]   A three-fluid model of two-phase dispersed-annular flow [J].
Alipchenkov, VM ;
Nigmatulin, RI ;
Soloviev, SL ;
Stonik, OG ;
Zaichik, LI ;
Zeigarnik, YA .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (24) :5323-5338
[3]  
Amsden A. A., 2000, SAE PAP 2000010271
[4]  
[Anonymous], 2011, Ansys Fluent Theory Guide
[5]   Annular flow entrainment rate experiment in a small vertical pipe [J].
de Bertodano, MAL ;
Jan, CS ;
Beus, SG .
NUCLEAR ENGINEERING AND DESIGN, 1997, 178 (01) :61-70
[6]  
Falcone G, 2009, DEV PET SCI, V54, P229
[7]   Prediction of the effects of liquid viscosity on interfacial shear stress and frictional pressure drop in vertical upward gas-liquid annular flow [J].
Fukano, T ;
Furukawa, T .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1998, 24 (04) :587-603
[8]   Numerical investigation of wet gas flow in Venturi meter [J].
He, Denghui ;
Bai, Bofeng .
FLOW MEASUREMENT AND INSTRUMENTATION, 2012, 28 :1-6
[9]   A multidimensional model for annular gas-liquid flow [J].
Kishore, BN ;
Jayanti, S .
CHEMICAL ENGINEERING SCIENCE, 2004, 59 (17) :3577-3589
[10]   A two-phase, two-component model for vertical upward gas-liquid annular flow [J].
Liu, Y. ;
Cui, J. ;
Li, W. Z. .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2011, 32 (04) :796-804