Stretchable, Multiplexed pH Sensors With Demonstrations on Rabbit and Human Hearts Undergoing Ischemia

被引:111
作者
Chung, Hyun-Joong [1 ,2 ]
Sulkin, Matthew S. [3 ]
Kim, Jong-Seon [4 ]
Goudeseune, Camille [5 ]
Chao, Hsin-Yun [2 ]
Song, Joseph W. [2 ]
Yang, Sang Yoon [2 ]
Hsu, Yung-Yu [6 ]
Ghaffari, Roozbeh [6 ]
Efimov, Igor R. [3 ]
Rogers, John A. [7 ,8 ]
机构
[1] Univ Alberta, Dept Chem & Mat Engn, Edmonton, AB T6G 2V4, Canada
[2] Univ Illinois, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[3] Washington Univ, Dept Biomed Engn, St Louis, MO 63130 USA
[4] Korea Adv Inst Sci & Technol, Dept Chem & Biomol Engn Program BK21, Taejon 305701, South Korea
[5] Univ Illinois, Illinois Simulator Lab, Beckman Inst, Urbana, IL 61801 USA
[6] MC10 Inc, Cambridge, MA 02140 USA
[7] Univ Illinois, Dept Mat Sci & Engn Chem, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[8] Univ Illinois, Frederick Seitz Mat Res Lab, Urbana, IL 61801 USA
关键词
heart ischemia; microfabrication; pH sensor; spatiotemporal mapping; stretchable electronics; NEAR-INFRARED SPECTROSCOPY; HYDROUS IRIDIUM OXIDE; OF-THE-ART; IN-VIVO; INTRACELLULAR PH; METAL-OXIDE; ELECTRONICS; STATE; FABRICATION; CIRCUITS;
D O I
10.1002/adhm.201300124
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stable pH is an established biomarker of health, relevant to all tissues of the body, including the heart. Clinical monitoring of pH in a practical manner, with high spatiotemporal resolution, is particularly difficult in organs such as the heart due to its soft mechanics, curvilinear geometry, heterogeneous surfaces, and continuous, complex rhythmic motion. The results presented here illustrate that advanced strategies in materials assembly and electrochemical growth can yield interconnected arrays of miniaturized IrOx pH sensors encapsulated in thin, low-modulus elastomers to yield conformal monitoring systems capable of noninvasive measurements on the surface of the beating heart. A thirty channel custom data acquisition system enables spatiotemporal pH mapping with a single potentiostat. In vitro testing reveals super-Nernstian sensitivity with excellent uniformity (69.9 +/- 2.2 mV/pH), linear response to temperature (-1.6 mV degrees C-1), and minimal influence of extracellular ions (<3.5 mV). Device examples include sensor arrays on balloon catheters and on skin-like stretchable membranes. Real-time measurement of pH on the surfaces of explanted rabbit hearts and a donated human heart during protocols of ischemia-reperfusion illustrate some of the capabilities. Envisioned applications range from devices for biological research, to surgical tools and long-term implants.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 47 条
  • [1] Heterogeneous three-dimensional electronics by use of printed semiconductor nanomaterials
    Ahn, Jong-Hyun
    Kim, Hoon-Sik
    Lee, Keon Jae
    Jeon, Seokwoo
    Kang, Seong Jun
    Sun, Yugang
    Nuzzo, Ralph G.
    Rogers, John A.
    [J]. SCIENCE, 2006, 314 (5806) : 1754 - 1757
  • [2] Albert K. J., 2002, BIOMEDICAL DIAGNOSTI
  • [3] Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies
    Bezbaruah, AN
    Zhang, TC
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (22) : 5726 - 5733
  • [4] Anion and water involvement in hydrous Ir oxide redox reactions in acidic solutions
    Bock, C
    Birss, VI
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 475 (01): : 20 - 27
  • [5] PH sensors with lithium lanthanum titanate sensitive material: applications in food industry
    Bohnke, C
    Duroy, H
    Fourquet, JL
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03) : 240 - 247
  • [6] PREPARATION OF AN OXIDIZED IRIDIUM ELECTRODE AND THE VARIATION OF ITS POTENTIAL WITH PH
    BURKE, LD
    MULCAHY, JK
    WHELAN, DP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 163 (1-2): : 117 - 128
  • [7] Chan KWY, 2013, NAT MATER, V12, P268, DOI [10.1038/NMAT3525, 10.1038/nmat3525]
  • [8] Fabrication of Releasable Single-Crystal Silicon-Metal Oxide Field-Effect Devices and Their Deterministic Assembly on Foreign Substrates
    Chung, Hyun-Joong
    Kim, Tae-il
    Kim, Hoon-Sik
    Wells, Spencer A.
    Jo, Sungjin
    Ahmed, Numair
    Jung, Yei Hwan
    Won, Sang Min
    Bower, Christopher A.
    Rogers, John A.
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2011, 21 (16) : 3029 - 3036
  • [9] García-Martín ML, 2001, CANCER RES, V61, P6524
  • [10] Thin-film IrOx pH microelectrode for microfluidic-based microsystems
    Ges, IA
    Ivanov, BL
    Schaffer, DK
    Lima, EA
    Werdich, AA
    Baudenbacher, FJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) : 248 - 256