Determining Coolant Flow Rate Distribution In The Fuel-Modified TRIGA Plate Reactor

被引:3
作者
Hastuti, Endiah Puji [1 ]
Widodo, Surip [1 ]
Isnaini, M. Darwis [1 ]
Rina, Geni S. [1 ]
Syaiful, B. [1 ]
机构
[1] Ctr Nucl Reactor Technol & Safety, Bld 80 PUSPIPTEK Area, Serpong 15310, South Tangerang, Indonesia
来源
INTERNATIONAL CONFERENCE ON NUCLEAR ENERGY TECHNOLOGIES AND SCIENCES (ICONETS 2017) | 2018年 / 962卷
关键词
CAUDVAP code; COOLODN code; flow distribution; modified reactor; TRIGA plate;
D O I
10.1088/1742-6596/962/1/012045
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
TRIGA 2000 reactor in Bandung is planned to have the fuel element replaced, from cylindrical uranium and zirconium-hydride (U-ZrH) alloy to U3Si2-Al plate type of low enriched uranium of 19.75% with uranium density of 2.96 gU/cm(3), while the reactor power is maintained at 2 MW. This change is planned to anticipate the discontinuity of TRIGA fuel element production. The selection of this plate-type fuel element is supported by the fact that such fuel type has been produced in Indonesia and used in MPR-30 safely since 2000. The core configuration of plate-type-fuelled TRIGA reactor requires coolant flow rate through each fuel element channel in order to meet its safety function. This paper is aimed to describe the results of coolant flow rate distribution in the TRIGA core that meets the safety function at normal operation condition, physical test, shutdown, and at initial event of loss of coolant flow due power supply interruption. The design analysis to determine coolant flow rate in this paper employs CAUDVAP and COOLODN computation code. The designed coolant flow rate that meets the safety criteria of departure from nucleate boiling ratio (DNBR), onset of flow instability ratio (OFIR), and Delta T onset of nucleate boiling (ONB), indicates that the minimum flow rate required to cool the plate-type fuelled TRIGA core at 2 MW is 80 kg/s. Therefore, it can be concluded that the operating limitation condition (OLC) for the minimum flow rate is 80 kg/s; the 72 kg/s is to cool the active core; while the minimum flow rate for coolant flow rate drop is limited to 68 kg/s with the coolant inlet temperature 35 degrees C. This thermohydraulic design also provides cooling for 4 positions irradiation position (IP) utilization and 1 central irradiation position (CIP) with end fitting inner diameter (ID) of 10 mm and 20 mm, respectively.
引用
收藏
页数:11
相关论文
共 14 条
[1]   Transient analyses of the Jordanian 5 MW research reactor under LOEP accident [J].
Al-Yahia, Omar S. ;
Lee, Ho ;
Jo, Daeseong .
ANNALS OF NUCLEAR ENERGY, 2016, 87 :575-583
[2]   Thermal-hydraulics features of the use of LEU U3Si2 fuel in low-power reactors [J].
Albarhoum, M. .
ANNALS OF NUCLEAR ENERGY, 2010, 37 (10) :1351-1355
[3]  
Anwar IR, 2017, AIP C P, P1799
[4]   Preliminary thermal-hydraulic safety analysis of Tehran research reactor during fuel irradiation experiment [J].
Arshi, S. Safaei ;
Khalafi, H. ;
Mirvakili, S. M. .
PROGRESS IN NUCLEAR ENERGY, 2015, 79 :32-39
[5]  
BATAN Indonesia, 2011, SAF AN REP RSG GAS M, V10
[6]   Steady-state thermal-hydraulic analysis of the Moroccan TRIGA MARK II reactor by using PARET/ANL and COOLOD-N2 codes [J].
Boulaich, Y. ;
Nacir, B. ;
El Bardouni, T. ;
Zoubair, M. ;
El Bakkari, B. ;
Merroun, O. ;
El Younoussi, C. ;
Htet, A. ;
Boukhal, H. ;
Chakir, E. .
NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (01) :270-273
[7]   Three-dimensional analysis of flow blockage accident in Tehran MTR research reactor core using CFD [J].
Davari, Amin ;
Mirvakili, Seyed Mohammad ;
Abedi, Ebrahim .
PROGRESS IN NUCLEAR ENERGY, 2015, 85 :605-612
[8]  
Endiah PH, 2015, J TEK REAKTOR NUKL, V17, P127
[9]   Development of thermal hydraulic and margin analysis code for steady state forced and natural convective cooling of plate type fuel research reactors [J].
Jo, Daeseong ;
Park, Jonghark ;
Chae, Heetaek .
PROGRESS IN NUCLEAR ENERGY, 2014, 71 :39-51
[10]  
Prasetyo B, 2014, J SCI TEK NUKL INDON, V15, P69