Statistical performance analysis of transient-based extended blockage detection in a water supply pipeline

被引:21
|
作者
Keramat, Alireza [1 ]
Zanganeh, Roohollah [2 ]
机构
[1] Jundi Shapur Univ Technol, Civil Engn Dept, Dezful, Iran
[2] Iran Univ Sci & Technol, Dept Civil Engn, Tehran, Iran
来源
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA | 2019年 / 68卷 / 05期
关键词
blockage detection; Cramer-Rao lower bound; direct differentiation method; method of characteristics; performance analysis; water hammer; PIPES; DETERIORATION; FREQUENCY; SYSTEMS;
D O I
10.2166/aqua.2019.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of the present research is to quantify the maximum feasible accuracy (location and size) for the transient-based blockage detection in a water supply pipeline. Owing to the randomness of transient measurements, a performance bound for the extended blockage detection exists which estimated parameters cannot exceed. The Cramer-Rao lower bound (CRLB) theorem is utilized to compute the lower bound variance of noise-induced estimation errors. It gives the minimum mean square error of any estimator according to information obtained from measurements and quantified by Fisher information. The Fisher information matrix is computed using direct differentiation of the compatibility equations obtained by the method of characteristics. The influence of relevant physical parameters including valve closure time, measurement time length and noise level on the best possible localization of blockage is investigated. The connection between the signal bandwidth, noise level and the performance limit is quantified for a typical case study. The results demonstrate trade-off between the size and the location/length of blockage estimates subject to different maneuver times, roughly offering half the wave speed times maneuver duration as the resolution limit.
引用
收藏
页码:346 / 357
页数:12
相关论文
共 50 条
  • [32] Kernelized technique for outliers detection to monitoring water pipeline based on WSNs
    Ayadi, Aya
    Ghorbel, Oussama
    BenSalah, M. S.
    Abid, Mohamed
    COMPUTER NETWORKS, 2019, 150 : 179 - 189
  • [33] Accuracy and Sensitivity Evaluation of TFR Method for Leak Detection in Multiple-Pipeline Water Supply Systems
    Duan, Huan-Feng
    WATER RESOURCES MANAGEMENT, 2018, 32 (06) : 2147 - 2164
  • [34] Research on the localization of pipe burst based on transient flow in a water supply network
    Zheng, Guolei
    Tian, Yimei
    Li, Zhengxuan
    Cheng, Jing
    Liang, Jianwen
    Peng, Sen
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024, 23 (05): : 2679 - 2697
  • [35] A Distributed Computing Solution Based on Distributed Kalman Filter for Leak Detection in WSN-Based Water Pipeline Monitoring
    Nkemeni, Valery
    Mieyeville, Fabien
    Tsafack, Pierre
    SENSORS, 2020, 20 (18) : 1 - 38
  • [36] Research on VMD based adaptive denoising method applied to water supply pipeline leakage location
    Li, Juan
    Chen, Yu
    Qian, Zhihong
    Lu, Changgang
    MEASUREMENT, 2020, 151 (151)
  • [37] Performance analysis and optimal operational planning of water supply systems
    Yokoyama, Ryohei
    Sameshima, Shoichi
    Ito, Koichi
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2007, 73 (05): : 1472 - 1479
  • [38] Faster Inverse Transient Analysis with a Head-Based Method of Characteristics and a Flexible Computational Grid for Pipeline Condition Assessment
    Zhang, Chi
    Gong, Jinzhe
    Zecchin, Aaron
    Lambert, Martin
    Simpson, Angus
    JOURNAL OF HYDRAULIC ENGINEERING, 2018, 144 (04)
  • [39] Analysis and prediction of chilled water plant performance based on multivariate statistical methods and large historical data
    St-Laurent, Philip Beaulieu
    Gosselin, Louis
    Duchesne, Carl
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 90 : 132 - 144