Safety and feasibility of breast lesion localization using magnetic seeds (Magseed): a multi-centre, open-label cohort study

被引:109
作者
Harvey, James R. [1 ]
Lim, Yit [1 ]
Murphy, John [1 ]
Howe, Miles [1 ]
Morris, Julie [1 ]
Goyal, Amit [2 ]
Maxwell, Anthony J. [1 ,3 ]
机构
[1] Univ Manchester, Wythenshawe Hosp, Univ Hosp South Manchester, Manchester Acad Hlth Sci Ctr,Nightingale Ctr, Southmoor Rd, Manchester M23 9LT, Lancs, England
[2] Royal Derby Hosp, Derby DE22 3NE, Derbyshire, England
[3] Univ Manchester, Fac Biol Med & Hlth, Sch Hlth Sci, Div Informat Imaging & Data Sci, Manchester M13 9PT, Lancs, England
关键词
Mastectomy; Breast cancer; Lumpectomy; Seed localization; Magnetic; BIOPSY;
D O I
10.1007/s10549-018-4709-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose Wire localization has several disadvantages, notably wire migration and difficulty scheduling the procedure close to surgery. Radioactive seed localization overcomes these disadvantages, but implementation is limited due to radiation safety requirements. Magnetic seeds potentially offer the logistical benefits and transcutaneous detection equivalence of a radioactive seed, with easier implementation. This study was designed to evaluate the feasibility and safety of using magnetic seeds for breast lesion localization. Methods A two-centre open-label cohort study to assess the feasibility and safety of magnetic seed (Magseed) localization of breast lesions. Magseeds were placed under radiological guidance into women having total mastectomy surgery. The primary outcome measure was seed migration distance. Secondary outcome measures included accuracy of placement, ease of transcutaneous detection, seed integrity and safety. Results Twenty-nine Magseeds were placed into the breasts of 28 patients under ultrasound guidance. There was no migration of the seeds between placement and surgery. Twenty-seven seeds were placed directly in the target lesion with the other seeds being 2 and 3 mm away. All seeds were detectable transcutaneously in all breast sizes and at all depths. There were no complications or safety issues. Conclusions Magnetic seeds are a feasible and safe method of breast lesion localization. They can be accurately placed, demonstrate no migration in this feasibility study and are detectable in all sizes and depths of breast tissue. Now that safety and feasibility have been demonstrated, further clinical studies are required to evaluate the seed's effectiveness in wide local excision surgery.
引用
收藏
页码:531 / 536
页数:6
相关论文
共 9 条
[1]  
[Anonymous], 2014, JAARR NBCA
[2]   Localization techniques for guided surgical excision of non-palpable breast lesions [J].
Chan, Benjamin K. Y. ;
Wiseberg-Firtell, Jill A. ;
Jois, Ramesh H. S. ;
Jensen, Katrin ;
Audisio, Riccardo A. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (12)
[3]   Radioactive Seed Localization or Wire-guided Localization of Nonpalpable Invasive and In Situ Breast Cancer A Randomized, Multicenter, Open-label Trial [J].
Langhans, Linnea ;
Tvedskov, Tove F. ;
Klausen, Thomas L. ;
Jensen, Maj-Britt ;
Talman, Maj-Lis ;
Vejborg, Ilse ;
Benian, Cemil ;
Roslind, Anne ;
Hermansen, Jonas ;
Oturai, Peter S. ;
Bentzon, Niels ;
Kroman, Niels .
ANNALS OF SURGERY, 2017, 266 (01) :29-35
[4]   Beyond Wires and Seeds: Reflector-guided Breast Lesion Localization and Excision [J].
Mango, Victoria L. ;
Wynn, Ralph T. ;
Feldman, Sheldon ;
Friedlander, Lauren ;
Desperito, Elise ;
Patel, Sejal N. ;
Gomberawalla, Ameer ;
Ha, Richard .
RADIOLOGY, 2017, 284 (02) :365-371
[5]   Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: A randomized clinical trial [J].
Rahusen, FD ;
Bremers, AJA ;
Fabry, HFJ ;
van Amerongen, AHMT ;
Boom, RPA ;
Meijer, S .
ANNALS OF SURGICAL ONCOLOGY, 2002, 9 (10) :994-998
[6]   Randomized clinical trial comparing radioisotope occult lesion localization and wire-guided excision for biopsy of occult breast lesions [J].
Rampaul, RS ;
Bagnall, M ;
Burrell, H ;
Pinder, SE ;
Evans, AJ ;
Macmillan, RD .
BRITISH JOURNAL OF SURGERY, 2004, 91 (12) :1575-1577
[7]   Feasibility of magnetic marker localisation for non-palpable breast cancer [J].
Schermers, B. ;
van der Hage, J. A. ;
Loo, C. E. ;
Peeter, M. T. F. D. Vrancken ;
Winter-Warnars, H. A. O. ;
van Duijnhoven, F. ;
ten Haken, B. ;
Muller, S. H. ;
Ruers, T. J. M. .
BREAST, 2017, 33 :50-56
[8]   The Central-European SentiMag study: Sentinel lymph node biopsy with superparamagnetic iron oxide (SPIO) vs. radioisotope [J].
Thill, Marc ;
Kurylcio, Andrzej ;
Welter, Rebekka ;
van Haasteren, Viviana ;
Grosse, Britta ;
Berclaz, Gilles ;
Polkowski, Wojciech ;
Hauser, Nik .
BREAST, 2014, 23 (02) :175-179
[9]   Radioactive Seed Localization Versus Wire-Guided Localization for Nonpalpable Breast Cancer: A Cost and Operating Room Efficiency Analysis [J].
Zhang, Yimeng ;
Seely, Jean ;
Cordeiro, Erin ;
Hefler, Joshua ;
Thavorn, Kednapa ;
Mahajan, Mukta ;
Domina, Sue ;
Aro, Jon ;
Ibrahim, Andrea Marie ;
Arnaout, Angel ;
Gravel, Denis ;
Nessim, Carolyn .
ANNALS OF SURGICAL ONCOLOGY, 2017, 24 (12) :3567-3573