Kidney Boundary Detection Algorithm Based on Extended Maxima Transformations for Computed Tomography Diagnosis

被引:6
作者
Les, Tomasz [1 ]
Markiewicz, Tomasz [1 ,2 ]
Dziekiewicz, Miroslaw [2 ]
Lorent, Malgorzata [2 ]
机构
[1] Warsaw Univ Technol, Fac Elect Engn, Pl Politech 1, PL-00661 Warsaw, Poland
[2] Mil Inst Med, 128 Szaserow St, PL-04141 Warsaw, Poland
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 21期
关键词
computer-aided diagnosis; image segmentation; artificial intelligence; kidney disease diagnosis; TEXTURE ANALYSIS; RENAL TUMORS; SEGMENTATION;
D O I
10.3390/app10217512
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article describes the automated computed tomography (CT) image processing technique supporting kidney detection. The main goal of the study is a fully automatic generation of a kidney boundary for each slice in the set of slices obtained in the computed tomography examination. This work describes three main tasks in the process of automatic kidney identification: the initial location of the kidneys using the U-Net convolutional neural network, the generation of an accurate kidney boundary using extended maxima transformation, and the application of the slice scanning algorithm supporting the process of generating the result for the next slice, using the result of the previous one. To assess the quality of the proposed technique of medical image analysis, automatic numerical tests were performed. In the test section, we presented numerical results, calculating the F1-score of kidney boundary detection by an automatic system, compared to the kidneys boundaries manually generated by a human expert from a medical center. The influence of the use of U-Net support in the initial detection of the kidney on the final F1-score of generating the kidney outline was also evaluated. The F1-score achieved by the automated system is 84% +/- 10% for the system without U-Net support and 89% +/- 9% for the system with U-Net support. Performance tests show that the presented technique can generate the kidney boundary up to 3 times faster than raw U-Net-based network. The proposed kidney recognition system can be successfully used in systems that require a very fast image processing time. The measurable effect of the developed techniques is a practical help for doctors, specialists from medical centers dealing with the analysis and description of medical image data.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
[41]   A novel image-domain-based cone-beam computed tomography enhancement algorithm [J].
Li, Xiang ;
Li, Tianfang ;
Yang, Yong ;
Heron, Dwight E. ;
Huq, M. Saiful .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09) :2755-2766
[42]   A clinically applicable AI system for diagnosis of congenital heart diseases based on computed tomography images [J].
Xu, Xiaowei ;
Jia, Qianjun ;
Yuan, Haiyun ;
Qiu, Hailong ;
Dong, Yuhao ;
Xie, Wen ;
Yao, Zeyang ;
Zhang, Jiawei ;
Nie, Zhiqaing ;
Li, Xiaomeng ;
Shi, Yiyu ;
Zou, James Y. ;
Huang, Meiping ;
Zhuang, Jian .
MEDICAL IMAGE ANALYSIS, 2023, 90
[43]   Prior knowledge-based precise diagnosis of blend sign from head computed tomography [J].
Wang, Chen ;
Yu, Jiefu ;
Zhong, Jiang ;
Han, Shuai ;
Qi, Yafei ;
Fang, Bin ;
Li, Xue .
FRONTIERS IN NEUROSCIENCE, 2023, 17
[44]   A computer aided diagnosis framework for detection and classification of interstitial lung diseases using computed tomography (CT) images [J].
Kumar, B. P. Santosh ;
Reddy, A. Pullareddy ;
Siva, D. ;
Badashah, Syed Jahangir ;
Shaik, Shafiulla Basha ;
Karupusamy, Sathishkumar ;
Mulam, Harikrishna .
APPLIED NANOSCIENCE, 2022, 12 (09) :2533-2550
[45]   A computer aided diagnosis framework for detection and classification of interstitial lung diseases using computed tomography (CT) images [J].
B. P. Santosh Kumar ;
A. Pullareddy Reddy ;
D. Siva ;
Syed Jahangir Badashah ;
Shafiulla Basha Shaik ;
Sathishkumar Karupusamy ;
Harikrishna Mulam .
Applied Nanoscience, 2022, 12 :2533-2550
[46]   An automated algorithm for the detection of cortical interruptions on high resolution peripheral quantitative computed tomography images of finger joints [J].
Peters, M. ;
Scharmga, A. ;
de Jong, J. ;
van Tubergen, A. ;
Geusens, P. ;
Arts, J. J. ;
Loeffen, D. ;
Weijers, R. ;
van Rietbergen, B. ;
van den Bergh, J. .
PLOS ONE, 2017, 12 (04)
[47]   Lung nodule detection on thoracic computed tomography images: Preliminary evaluation of a computer-aided diagnosis system [J].
Gurcan, MN ;
Sahiner, B ;
Petrick, N ;
Chan, HP ;
Kazerooni, EA ;
Cascade, PN ;
Hadjiiski, L .
MEDICAL PHYSICS, 2002, 29 (11) :2552-2558
[48]   Deep Learning Techniques for Lung Cancer Diagnosis with Computed Tomography Imaging: A Systematic Review for Detection, Segmentation, and Classification [J].
Abdullahi, Kabiru ;
Ramakrishnan, Kannan ;
Ali, Aziah Binti .
INFORMATION, 2025, 16 (06)
[49]   Evaluation of Flaw Detection Algorithm Using Simulated X-Ray Computed Tomography of Ground Truth Data [J].
Kim, Felix H. ;
Pintar, Adam L. ;
Scott, John Henry J. ;
Garboczi, Edward J. .
JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS, 2023, 6 (04)
[50]   Extended Absolute Fuzzy Connectedness Segmentation Algorithm Utilizing Region and Boundary-Based Information [J].
T. H. Farag ;
W. A. Hassan ;
H. A. Ayad ;
A. S. AlBahussain ;
U. A. Badawi ;
M. K. Alsmadi .
Arabian Journal for Science and Engineering, 2017, 42 :3573-3583