Pixellated thallium bromide detectors for gamma-ray spectroscopy and imaging

被引:43
|
作者
Onodera, T [1 ]
Hitomi, K [1 ]
Shoji, T [1 ]
Hiratate, Y [1 ]
机构
[1] Tohoku Inst Technol, Dept Elect, Taihaku Ku, Sendai, Miyagi 9828577, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2004年 / 525卷 / 1-2期
关键词
thallium bromide; pixellated detector; X- and gamma-ray detector; imaging detector;
D O I
10.1016/j.nima.2004.03.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently, pixellated semiconductor detectors exhibit high-energy resolution, which have been studied actively and fabricated from CdTe, CZT and HgI2. Thallium bromide (TlBr) is a compound semiconductor characterized with its high atomic numbers (Tl = 81, Br = 35) and high density (7.56 g/cm(3)). Thus, TlBr exhibits higher photon stopping power than other semiconductor materials used for radiation detector fabrication such as CdTe, CZT and HgI2. The wide band gap of TlBr (2.68 eV) permits the detectors low-noise operation at around room temperature. Our studies made an effort to fabricate pixellated TlBr detectors had sufficient detection efficiency and good charge collection efficiency. In this study, pixellated TIBr detectors were fabricated from the crystals purified by the multipass zone-refining method and grown by the horizontal traveling molten zone (TMZ) method. The TIBr detector has a continuous cathode over one crystal surface and 3 x 3 pixellated anodes (0.57 x 0.57 mm(2) each) surrounded by a guard ring on the opposite surface. The electrodes were realized by vacuum evaporation of palladium through a shadow mask. Typical thickness of the detector was 2 mm. Spectrometric performance of the TIBr detectors was tested by irradiating them with Am-241 (59.5 keV), (CO)-C-57 (122 keV) and Cs-137 (662 keV) gamma-ray sources at temperature of -20degreesC. Energy resolutions (FWHM) were measured to be 4.0, 6.0 and 9.7 keV for 59.5, 122 and 662 keV gamma-rays, respectively. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [1] Characterization of Pixellated Thallium Bromide Radiation Detectors for Gamma-ray Spectroscopy
    Nowicki, Suzanne
    Doenmez, Burcin
    Anderson, Stephen
    He, Zhong
    Shah, Kanai
    Cirignano, Leonard
    Kim, Hadong
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5130 - +
  • [2] Pixellated thallium bromide X- and gamma-ray detectors
    Onodera, T
    Hitomi, K
    Shoji, T
    Hiratate, Y
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3428 - 3430
  • [3] Large-volume thallium bromide detectors for gamma-ray spectroscopy
    Hitomi, K
    Muroi, O
    Matsumoto, M
    Shoji, T
    Hiratate, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2313 - 2316
  • [4] Thallium bromide optical and radiation detectors for X-ray and gamma-ray spectroscopy
    Hitomi, K
    Matsumoto, M
    Muroi, O
    Shoji, T
    Hiratate, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2526 - 2529
  • [5] Thallium bromide optical and radiation detectors for X- and gamma-ray spectroscopy
    Hitomi, K
    Matsumoto, M
    Muroi, O
    Shoji, T
    Hiratate, Y
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2406 - 2409
  • [6] THALLIUM BROMIDE SEMICONDUCTOR X-RAY AND GAMMA-RAY DETECTORS
    OLSCHNER, F
    SHAH, KS
    LUND, JC
    ZHANG, J
    DALEY, K
    MEDRICK, S
    SQUILLANTE, MR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 504 - 508
  • [7] Spatial pileup considerations for pixellated gamma-ray detectors
    Furenlid, LR
    Clarkson, E
    Marks, DG
    Barrett, HH
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 713 - 717
  • [8] Spectroscopic performance of pixellated thallium bromide detectors
    Onodera, T
    Hitomi, K
    Shoji, T
    Hiratate, Y
    Kitaguchi, H
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4448 - 4450
  • [9] Spatial pileup considerations for pixellated gamma-ray detectors
    Furenlid, LR
    Clarkson, E
    Marks, DG
    Barrett, HH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1399 - 1403
  • [10] Spectroscopic performance of pixellated thallium bromide detectors
    Onodera, T
    Hitomi, K
    Shoji, T
    Hiratate, Y
    Kitaguchi, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1999 - 2002