Comparison of Cadaveric and Isomorphic Three-Dimensional Printed Models in Temporal Bone Education

被引:84
作者
Hochman, Jordan B. [1 ]
Rhodes, Charlotte [3 ]
Wong, Dana [1 ]
Kraut, Jay [3 ]
Pisa, Justyn [2 ]
Unger, Bertram [3 ]
机构
[1] Univ Manitoba, Dept Otolaryngol Head & Neck Surg, Winnipeg, MB, Canada
[2] Univ Manitoba, Hlth Sci Ctr, Winnipeg, MB, Canada
[3] Univ Manitoba, Dept Continuing Med Educ, Winnipeg, MB, Canada
关键词
temporal; bone; surgery; training; education; middle ear; auditory physiology; evidence-based medicine; SIMULATION; SURGERY; FIDELITY;
D O I
10.1002/lary.24919
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: Current three-dimensional (3D) printed simulations are complicated by insufficient void spaces and inconsistent density. We describe a novel simulation with focus on internal anatomic fidelity and evaluate against template/identical cadaveric education. Study Design: Research ethics board-approved prospective cohort study. Methods: Generation of a 3D printed temporal bone was performed using a proprietary algorithm that deconstructs the digital model into slices prior to printing. This supplemental process facilitates removal of residual material from air-containing spaces and permits requisite infiltrative access to the all regions of the model. Ten otolaryngology trainees dissected a cadaveric temporal bone (CTB) followed by a matched/isomorphic 3D printed bone model (PBM), based on derivative micro-computed tomography data. Participants rated 1) physical characteristics, 2) specific anatomic constructs, 3) usefulness in skill development, and 4) perceived educational value. The survey instrument employed a seven-point Likert scale. Results: Trainees fell physical characteristics of the PBM were quite similar to CTB, with highly ranked cortical (5.5 +/- 1.5) and trabecular (5.2 +/- 1.3) bone drill quality. The overall model was considered comparable to CTB (5.9 +/- 0.74), with respectable air cell reproduction (6.1 +/- 1.1). Internal constructs were rated as satisfactory (range, 4.9-6.2). The simulation was considered a beneficial training tool for all types of mastoidectomy (range, 5.9-6.6), posterior tympanotomy (6.5 +/- 0.71), and skull base approaches (range, 6-6.5). Participants believed the model to be an effective training instrument (6.7 +/- 0.68), which should be incorporated into the temporal bone lab (7.0 +/- 0.0). The PBM was thought to improve confidence (6.7 +/- 0.68) and operative performance (6.7 +/- 0.48). Conclusions: Study participants found the PBM to be an effective platform that compared favorably to CTB. The model was considered a valuable adjunctive training tool with both realistic mechanical and visual character.
引用
收藏
页码:2353 / 2357
页数:5
相关论文
共 20 条
[1]  
Agus M, 2002, ST HEAL T, V85, P17
[2]  
[Anonymous], 2012, VISIBLE EAR SIMULATI
[3]   Artificial petrous bone produced by stereolithography for microsurgical dissecting exercises [J].
Begall, K ;
Vorwerk, U .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1998, 60 (05) :241-245
[4]  
Bryan JA, 2001, THESIS OHIO STATE U
[5]   Analysis of errors in medical rapid prototyping models [J].
Choi, JY ;
Choi, JH ;
Kim, NK ;
Kim, Y ;
Lee, JK ;
Kim, MK ;
Lee, JH ;
Kim, MJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (01) :23-32
[6]   Establishing a temporal bone laboratory: considerations for ENT specialist training [J].
Fennessy, B. G. ;
O'Sullivan, P. .
IRISH JOURNAL OF MEDICAL SCIENCE, 2009, 178 (04) :393-395
[7]  
Hochman JB, 2014, OTOLARYNG HEAD NECK, V150, P448, DOI 10.1177/0194599813518008
[8]   Developing a virtual reality environment in Petrous bone surgery: A state-of-the-art review [J].
Jackson, A ;
John, TW ;
Thacker, NA ;
Ramsden, RT ;
Gillespie, JE ;
Gobbetti, J ;
Zanetti, J ;
Stone, R ;
Linney, AD ;
Alusi, GH ;
Franceschini, SS ;
Schwerdtner, A ;
Emmen, A .
OTOLOGY & NEUROTOLOGY, 2002, 23 (02) :111-121
[9]  
Lorensen WE., 1987, COMPUT GRAPH-UK, V21, P163, DOI [10.1145/37402.37422, DOI 10.1145/37402.37422]
[10]  
Mankovich N J, 1990, J Digit Imaging, V3, P200