Edge illumination X-ray phase-contrast imaging: nanoradian sensitivity at synchrotrons and translation to conventional sources

被引:12
作者
Diemoz, P. C. [1 ,2 ]
Endrizzi, M. [1 ]
Hagen, C. K. [1 ]
Rau, C. [3 ]
Bravin, A. [4 ]
Speller, R. D. [1 ]
Robinson, I. K. [2 ,5 ]
Olivo, A. [1 ,2 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
[2] Res Complex, Harwell, Berks, England
[3] Diamond Light Source, Harwell, Berks, England
[4] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[5] London Ctr Nanotechnol, London WC1H 0AH, England
来源
22ND INTERNATIONAL CONGRESS ON X-RAY OPTICS AND MICROANALYSIS | 2014年 / 499卷
基金
英国工程与自然科学研究理事会;
关键词
TOMOGRAPHY; RETRIEVAL; WAVE;
D O I
10.1088/1742-6596/499/1/012006
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Edge illumination is an X-ray phase-contrast imaging technique that can be efficiently applied to both synchrotron radiation and laboratory sources. Its implementation with these two types of setups is here described, and a recently developed method to perform quantitative retrieval of the object attenuation and refraction properties is presented. We report results obtained at two synchrotron radiation facilities and with one of the setups installed in our laboratories at University College London, which show that very high angular sensitivities can be obtained with this technique. The effect of different experimental parameters on the achievable sensitivity is also analyzed. The obtained results will be a useful guide for the design and optimization of future experimental layouts.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Characterization of Osteoarthritic and Normal Human Patella Cartilage by Computed Tomography X-ray Phase-Contrast Imaging A Feasibility Study
    Coan, Paola
    Bamberg, Fabian
    Diemoz, Paul C.
    Bravin, Alberto
    Timpert, Kirsten
    Muetzel, Elisabeth
    Raya, Jose G.
    Adam-Neumair, Silvia
    Reiser, Maximilian F.
    Glaser, Christian
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (07) : 437 - 444
  • [2] Differential x-ray phase contrast imaging using a shearing interferometer
    David, C
    Nöhammer, B
    Solak, HH
    Ziegler, E
    [J]. APPLIED PHYSICS LETTERS, 2002, 81 (17) : 3287 - 3289
  • [3] Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging
    Diemoz, P. C.
    Hagen, C. K.
    Endrizzi, M.
    Olivo, A.
    [J]. APPLIED PHYSICS LETTERS, 2013, 103 (24)
  • [4] X-Ray Phase-Contrast Imaging with Nanoradian Angular Resolution
    Diemoz, P. C.
    Endrizzi, M.
    Zapata, C. E.
    Pesic, Z. D.
    Rau, C.
    Bravin, A.
    Robinson, I. K.
    Olivo, A.
    [J]. PHYSICAL REVIEW LETTERS, 2013, 110 (13)
  • [5] Effects of signal diffusion on x-ray phase contrast images
    Ignatyev, K.
    Munro, P. R. T.
    Speller, R. D.
    Olivo, A.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (07)
  • [6] X-RAY PLANE-WAVE TOPOGRAPHY OBSERVATION OF THE PHASE-CONTRAST FROM A NONCRYSTALLINE OBJECT
    INGAL, VN
    BELIAEVSKAYA, EA
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (11) : 2314 - 2317
  • [7] Visualization of small lesions in rat cartilage by means of laboratory-based x-ray phase contrast imaging
    Marenzana, Massimo
    Hagen, Charlotte K.
    Borges, Patricia Das Neves
    Endrizzi, Marco
    Szafraniec, Magdalena B.
    Ignatyev, Konstantin
    Olivo, Alessandro
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (24) : 8173 - 8184
  • [8] Method for automatization of the alignment of a laboratory based x-ray phase contrast edge illumination system
    Millard, T. P.
    Endrizzi, M.
    Ignatyev, K.
    Hagen, C. K.
    Munro, P. R. T.
    Speller, R. D.
    Olivo, A.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (08)
  • [9] Demonstration of X-Ray Talbot interferometry
    Momose, A
    Kawamoto, S
    Koyama, I
    Hamaishi, Y
    Takai, K
    Suzuki, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (7B): : L866 - L868
  • [10] Phase-contrast X-ray computed tomography for observing biological soft tissues
    Momose, A
    Takeda, T
    Itai, Y
    Hirano, K
    [J]. NATURE MEDICINE, 1996, 2 (04) : 473 - 475