Comparative study of Japanese frozen elephant trunk device for open aortic arch repairs

被引:27
作者
Ogino, Hitoshi [1 ]
Okita, Yutaka [2 ]
Uchida, Naomichi [3 ]
Kato, Masaaki [4 ]
Miyamoto, Shinji [5 ]
Matsuda, Hitoshi [6 ]
Nakai, Michikazu [7 ]
机构
[1] Tokyo Med Univ, Dept Cardiovasc Surg, Tokyo, Japan
[2] Takatsuki Gen, Cardioaort Ctr, Kobe Univ, Osaka, Japan
[3] Yao Tokushukai Hosp, Dept Cardiovasc Surg, Osaka, Japan
[4] Morinomiya Hosp, Dept Cardiovasc Surg, Osaka, Japan
[5] Oita Univ, Dept Cardiovasc Surg, Oita, Japan
[6] Natl Cerebral & Cardiovasc Ctr, Dept Vasc Surg, Osaka, Japan
[7] Natl Cerebral & Cardiovasc Ctr, Ctr Cerebral & Cardiovasc Dis Informat, Osaka, Japan
关键词
aortic aneurysm; aortic dissection; early outcome; frozen elephant trunk; total arch replacement; SELECTIVE CEREBRAL PERFUSION; MULTICENTER EARLY EXPERIENCE; OPEN STENT-GRAFT; THORACIC-SURGEONS; REPLACEMENT; DISSECTION; RISK; SOCIETY; IMPACT; 30-DAY;
D O I
10.1016/j.jtcvs.2021.03.079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We performed a multicenter prospective comparative study to determine the impact of a Japanese frozen elephant trunk device on total arch replacement compared with conventional repair without it. Methods: Between 2016 and 2019, a total of 684 patients (frozen elephant trunk procedure; n = 369; conventional repair, n = 315) from 41 institutions were enrolled. The 2 procedures were selected according to each center's strategy. Results: The frozen elephant trunk procedure was applied more for aortic dissection, whereas the conventional repairs were predominantly performed for aneurysms. In the former, only hypothermic circulatory arrest time was reduced among the intraoperative parameters. Although there were no differences in the 30-day and in-hospital mortality rates (0.8% and 1.6%, respectively, for the frozen elephant trunk procedure vs 0.3% and 0.6%, respectively, for conventional repair), the neurologic complication rates were significantly higher in stroke (5.7% vs 2.2%; P = .022) and paraplegia (1.6% vs 0%; P = .023). In the propensity score matching analyses using 11 variables, statistical significance disappeared in the differences for mortality and neurologic morbidity (stroke and paraplegia/paraparesis) rates of 194 patients of each group, although they were still higher for the frozen elephant trunk procedure. Conclusions: The early outcomes of total arch replacement with the frozen elephant trunk procedure were acceptable despite its higher prevalence of emergency or redo surgery, which was comparable to that of the conventional repair. This procedure had higher rates of spinal cord injury than the conventional repair, which is a disadvantage of this approach.
引用
收藏
页码:1681 / +
页数:14
相关论文
共 35 条
  • [1] EXTENSIVE AORTIC REPLACEMENT USING ELEPHANT TRUNK PROSTHESIS
    BORST, HG
    WALTERBUSCH, G
    SCHAPS, D
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 (01) : 37 - 40
  • [3] Complex thoracic aortic disease: Single-stage procedure with the frozen elephant trunk technique
    Di Bartolomeo, Roberto
    Pacini, Davide
    Savini, Carlo
    Pilato, Emanuele
    Martin-Suarez, Sofia
    Di Marco, Luca
    Di Eusanio, Marco
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (06) : S81 - S85
  • [4] Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury
    Flores, J
    Kunihara, T
    Shiiya, N
    Yoshimoto, K
    Matsuzaki, K
    Yasuda, K
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (02) : 336 - 342
  • [5] Contemporary open aortic arch repair with selective cerebral perfusion in the era of endovascular aortic repair
    Iba, Yutaka
    Minatoya, Kenji
    Matsuda, Hitoshi
    Sasaki, Hiroaki
    Tanaka, Hiroshi
    Kobayashi, Junjiro
    Ogino, Hitoshi
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03) : S72 - S77
  • [6] Comparative study of the frozen elephant trunk and classical elephant trunk techniques to supplement total arch replacement for acute type A aortic dissection
    Inoue, Yosuke
    Matsuda, Hitoshi
    Omura, Atsushi
    Seike, Yoshimasa
    Uehara, Kyokun
    Sasaki, Hiroaki
    Kobayashi, Junjiro
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (03) : 579 - 586
  • [7] Extensive primary repair of the thoracic aorta in Stanford type A acute aortic dissection by means of a synthetic vascular graft with a self-expandable stent
    Ishihara, H
    Uchida, N
    Yamasaki, C
    Sakashita, M
    Kanou, M
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (06) : 1035 - 1040
  • [8] Frozen elephant trunk with straight vascular prosthesis: single-center experience with a review of current trends
    Jakob, Heinz
    Moughal, Saad
    Bashir, Mohamad
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2020, 61 (03) : 301 - 307
  • [9] The frozen elephant trunk technique: A new treatment for thoracic aortic aneurysms
    Karck, M
    Chavan, A
    Hagl, C
    Friedrich, H
    Galanski, M
    Haverich, A
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (06) : 1550 - 1553
  • [10] Multiple factors predict the risk of spinal cord injury after the frozen elephant trunk technique for extended thoracic aortic disease
    Katayama, Keijiro
    Uchida, Naomichi
    Katayama, Akira
    Takahashi, Shinya
    Takasaki, Taiichi
    Kurosaki, Tatsuya
    Imai, Katsuhiko
    Sueda, Taijiro
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (04) : 616 - 620