Comparison of Abbott AxSYM and Roche Elecsys 2010 for measurement of BNP and NT-proBNP

被引:29
作者
Chien, Tzu-I
Chen, Hui-hou
Kao, Jau-Tsuen
机构
[1] Natl Taiwan Univ Hosp, Dept Lab Med, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Coll Med, Dept Clin Lab Sci & Med Biotechnol, Taipei 100, Taiwan
关键词
method comparison; BNP; NT-proBNP; congestive heart failure;
D O I
10.1016/j.cca.2006.01.017
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: B-type natriuretic peptide (BNP) and N-terminal pro-brain natriuretic peptide (NT-proBNP) are small cardiac hormones released from the heart. They can be used as an important aid to diagnose congestive heart failure (CHF). Methods: We compared the performances of the Abbott AxSYM and Roche Elecsys 2010 for the measurement of BNP and NT-proBNP. The first method uses a microparticle enzyme-linked immunoassay, whereas the other uses chemiluminescent immunometric assay. Results: The CVs using pooled sera ranged from 3.7% to 12.7% for the AxSYM and 0.9% to 2.2% for the Elecsys 2010. The Passing and Bablok regression was Elecsys 2010 NT-proBNP=7.23 x AxSYM BNP+2.53. The BNP in EDTA plasma was more stable than in serum. The immunoreactivity difference of NT-proBNP in serum or EDTA plasma was within 10% when stored at 4 degrees C or 25 degrees C for 72 h. Receiver operating characteristic (ROC) curves were different for both assays, and the areas under the curves were 0.704 and 0.841 for the AxSYM and Elecsys 2010 method, respectively. Conclusions: Both assays were not entirely specific for heart failure. The precision and stability for NT-proBNP was better than for BNP in serum. It is important to use method-appropriate reference ranges (or cutoff) for the BNP and NT-proBNP, respectively, in the assessment of CHF. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 21 条
  • [1] Circulating levels of cardiac natriuretic peptides (ANP and BNP) measured by highly sensitive and specific immunoradiometric assays in normal subjects and in patients with different degrees of heart failure
    Clerico, A
    Iervasi, G
    Del Chicca, MG
    Emdin, M
    Maffei, S
    Nannipieri, M
    Sabatino, L
    Forini, F
    Manfredi, C
    Donato, L
    [J]. JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 1998, 21 (03) : 170 - 179
  • [2] Stability of NT-proBNP in serum specimens collected in Becton Dickinson vacutainer (SST) tubes
    Dasgupta, A
    Chow, L
    Tso, G
    Nazareno, L
    [J]. CLINICAL CHEMISTRY, 2003, 49 (06) : 958 - 960
  • [3] DAVIDSON NC, 1994, J HYPERTENS, V12, P329
  • [4] ABC of heart failure - History and epidemiology
    Davis, RC
    Hobbs, FDR
    Lip, GYH
    [J]. BRITISH MEDICAL JOURNAL, 2000, 320 (7226) : 39 - 42
  • [5] ATRIAL NATRIURETIC FACTOR - A HORMONE PRODUCED BY THE HEART
    DEBOLD, AJ
    [J]. SCIENCE, 1985, 230 (4727) : 767 - 770
  • [6] Reliability of N-terminal pro-brain natriuretic peptide assay in diagnosis of heart failure: cohort study in representative and high risk community populations
    Hobbs, FDR
    Davis, RC
    Roalfe, AK
    Hare, R
    Davies, MK
    Kenkre, JE
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2002, 324 (7352): : 1498 - 1500A
  • [7] The role of the circulation in processing pro-brain natriuretic peptide (proBNP) to amino-terminal BNP and BNP-32
    Hunt, PJ
    Espiner, EA
    Nicholls, MG
    Richards, AM
    Yandle, TG
    [J]. PEPTIDES, 1997, 18 (10) : 1475 - 1481
  • [8] ISOLATION AND SEQUENCE DETERMINATION OF HUMAN-BRAIN NATRIURETIC PEPTIDE IN HUMAN ATRIUM
    KAMBAYASHI, Y
    NAKAO, K
    MUKOYAMA, M
    SAITO, Y
    OGAWA, Y
    SHIONO, S
    INOUYE, K
    YOSHIDA, N
    IMURA, H
    [J]. FEBS LETTERS, 1990, 259 (02) : 341 - 345
  • [9] Lower rather than higher levels of B-Type natriuretic peptides (NT-Pro-BNP and BNP) predict short-term mortality in end-stage heart failure patients treated with Nesiritide
    Miller, WL
    Burnett, JC
    Hartman, KA
    Henle, MP
    Burritt, MF
    Jaffe, AS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (06) : 837 - 841
  • [10] PASSING H, 1983, J CLIN CHEM CLIN BIO, V21, P709