Assessment of Improved Motion-Sensitized Driven Equilibrium (iMSDE) for Multi-contrast Vessel Wall Screening

被引:13
作者
Obara, Makoto [1 ,2 ]
Van Cauteren, Marc [3 ]
Honda, Masatoshi [1 ]
Imai, Yutaka [4 ]
Kuroda, Kagayaki [2 ]
机构
[1] Philips Elect Japan Ltd, Minato Ku, Tokyo 1088507, Japan
[2] Tokai Univ, Grad Sch Sch Sci & Technol, Course Sci & Technol, Hiratsuka, Kanagawa 25912, Japan
[3] Philips Healthcare, N Ryde, NSW, Australia
[4] Tokai Univ, Sch Med, Dept Radiol, Hiratsuka, Kanagawa 25912, Japan
关键词
black blood; MRI; MSDE; vessel wall imaging; CAROTID ATHEROSCLEROSIS; MAGNETIC-RESONANCE; PLAQUE; MRI; ASSOCIATION; SEQUENCE; EVENTS;
D O I
10.2463/mrms.2013-0036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T. Methods: Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR divided by the square root of scan time, lumen-tissue contrast-to-noise efficiency (CNReff), CNR divided by the square root of scan time, and tissue signal intensity ratio (SIR) were measured in both techniques and compared. Results: The iMSDE-TFE had higher SNReff and CNReff (P < 0.01) and strong correlation in SIR (R = 0.92) compared to DIR-TSE. Conclusion: The iMSDE-TFE sequence is an efficient technique for vessel wall screening.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 12 条
[1]  
Absil J, 2007, P 15 ANN M ISMRM BER, P12
[2]   Submillimeter isotropic resolution carotid wall MRI with swallowing compensation: Imaging results and semiautomated wall morphometry [J].
Koktzoglou, Ioannis ;
Li, Debiao .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :815-823
[3]   Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls [J].
Koktzoglou, Ioannis ;
Li, Debiao .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (01) :33-42
[4]   Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging [J].
Mani, V ;
Itskovich, VV ;
Szimtenings, M ;
Aguinaldo, JGS ;
Samber, DD ;
Mizsei, G ;
Fayad, ZA .
RADIOLOGY, 2004, 232 (01) :281-288
[5]  
MORAN P R, 1982, Magnetic Resonance Imaging, V1, P197
[6]   Carotid plaque signal differences among four kinds of T1-weighted magnetic resonance imaging techniques: A histopathological correlation study [J].
Saito, Ayumi ;
Sasaki, Makoto ;
Ogasawara, Kuniaki ;
Kobayashi, Masakazu ;
Hitomi, Jiro ;
Narumi, Shinsuke ;
Ohba, Hideki ;
Yamaguchi, Mao ;
Kudo, Kohsuke ;
Terayama, Yasuo .
NEURORADIOLOGY, 2012, 54 (11) :1187-1194
[7]   Association between carotid plaque characteristics and subsequent ischemic cerebrovascular events - A prospective assessment with MRI - Initial results [J].
Takaya, N ;
Yuan, C ;
Chu, BC ;
Saam, T ;
Underhill, H ;
Cai, JM ;
Tran, N ;
Polissar, NL ;
Isaac, C ;
Ferguson, MS ;
Garden, GA ;
Cramer, SC ;
Maravilla, KR ;
Hashimoto, B ;
Hatsukami, TS .
STROKE, 2006, 37 (03) :818-823
[8]   Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence [J].
Wang, Jinnan ;
Yarnykh, Vasily L. ;
Hatsukami, Thomas ;
Chu, Baocheng ;
Balu, Niranjan ;
Yuan, Chun .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :973-981
[9]   Enhanced Image Quality in Black-Blood MRI Using the Improved Motion-Sensitized Driven-Equilibrium (iMSDE) Sequence [J].
Wang, Jinnan ;
Yarnykh, Vasily L. ;
Yuan, Chun .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (05) :1256-1263
[10]  
Yamada N, 2007, AM J NEURORADIOL, V28, P287