Five Years MIQE Guidelines: The Case of the Arabian Countries

被引:10
作者
Nour, Afif M. Abdel [1 ]
Azhar, Esam [1 ,2 ]
Damanhouri, Ghazi [3 ]
Bustin, Stephen A. [4 ]
机构
[1] King Abdulaziz Univ, Special Infect Agents Unit Biosafety Level 3, King Fahd Med Res Ctr, Jeddah 21413, Saudi Arabia
[2] King Abdulaziz Univ, Med Lab Technol Dept, Fac Appl Med Sci, Jeddah 21413, Saudi Arabia
[3] King Abdulaziz Univ, King Fahd Med Res Ctr, Jeddah 21413, Saudi Arabia
[4] Anglia Ruskin Univ, Postgrad Med Inst, Fac Hlth Social Care & Educ, Cambridge, England
来源
PLOS ONE | 2014年 / 9卷 / 02期
关键词
MINIMUM INFORMATION; PCR; PUBLICATION; NEED;
D O I
10.1371/journal.pone.0088266
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The quantitative real time polymerase chain reaction (qPCR) has become a key molecular enabling technology with an immense range of research, clinical, forensic as well as diagnostic applications. Its relatively moderate instrumentation and reagent requirements have led to its adoption by numerous laboratories, including those located in the Arabian world, where qPCR, which targets DNA, and reverse transcription qPCR (RT-qPCR), which targets RNA, are widely used for region-specific biotechnology, agricultural and human genetic studies. However, it has become increasingly apparent that there are significant problems with both the quality of qPCR-based data as well as the transparency of reporting. This realisation led to the publication of the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines in 2009 and their more widespread adoption in the last couple of years. An analysis of the performance of biomedical research in the Arabian world between 2001-2005 suggests that the Arabian world is producing fewer biomedical publications of lower quality than other Middle Eastern countries. Hence we have analysed specifically the quality of RT-qPCR-based peer-reviewed papers published since 2009 from Arabian researchers using a bespoke iOS/Android app developed by one of the authors. Our results show that compliance with 15 essential MIQE criteria was low (median of 40%, range 0-93%) and few details on RNA quality controls (22% compliance), assays design (12%), RT strategies (32%), amplification efficiencies (30%) and the normalisation process (3%). These data indicate that one of the reasons for the poor performance of Arabian world biomedical research may be the low standard of any supporting qPCR experiments and identify which aspects of qPCR experiments require significant improvements.
引用
收藏
页数:6
相关论文
共 18 条
  • [1] Abdel Nour A, 2011, MIQE QPCR APP VERSIO
  • [2] [Anonymous], 2013, NATURE, V496, P398, DOI DOI 10.1038/496398A
  • [3] Arab nations lagging behind other Middle Eastern countries in biomedical research: a comparative study
    Benamer, Hani T. S.
    Bakoush, Omran
    [J]. BMC MEDICAL RESEARCH METHODOLOGY, 2009, 9
  • [4] The need for transparency and good practices in the qPCR literature
    Bustin, Stephen A.
    Benes, Vladimir
    Garson, Jeremy
    Hellemans, Jan
    Huggett, Jim
    Kubista, Mikael
    Mueller, Reinhold
    Nolan, Tania
    Pfaffl, Michael W.
    Shipley, Gregory
    Wittwer, Carl T.
    Schjerling, Peter
    Day, Philip J.
    Abreu, Monica
    Aguado, Begona
    Beaulieu, Jean-Francois
    Beckers, Anneleen
    Bogaert, Sara
    Browne, John A.
    Carrasco-Ramiro, Fernando
    Ceelen, Liesbeth
    Ciborowski, Kate
    Cornillie, Pieter
    Coulon, Stephanie
    Cuypers, Ann
    De Brouwer, Sara
    De Ceuninck, Leentje
    De Craene, Jurgen
    De Naeyer, Helene
    De Spiegelaere, Ward
    Deckers, Kato
    Dheedene, Annelies
    Durinck, Kaat
    Ferreira-Teixeira, Margarida
    Fieuw, Annelies
    Gallup, Jack M.
    Gonzalo-Flores, Sandra
    Goossens, Karen
    Heindryckx, Femke
    Herring, Elizabeth
    Hoenicka, Hans
    Icardi, Laura
    Jaggi, Rolf
    Javad, Farzad
    Karampelias, Michael
    Kibenge, Frederick
    Kibenge, Molly
    Kumps, Candy
    Lambertz, Irina
    Lammens, Tim
    [J]. NATURE METHODS, 2013, 10 (11) : 1063 - 1067
  • [5] Primer Sequence Disclosure: A Clarification of the MIQE Guidelines
    Bustin, Stephen A.
    Benes, Vladimir
    Garson, Jeremy A.
    Hellemans, Jan
    Huggett, Jim
    Kubista, Mikael
    Mueller, Reinhold
    Nolan, Tania
    Pfaffl, Michael W.
    Shipley, Gregory L.
    Vandesompele, Jo
    Wittwer, Carl T.
    [J]. CLINICAL CHEMISTRY, 2011, 57 (06) : 919 - 921
  • [6] MIQE precis: Practical implementation of minimum standard guidelines for fluorescence-based quantitative real-time PCR experiments
    Bustin, Stephen A.
    Beaulieu, Jean-Francois
    Huggett, Jim
    Jaggi, Rolf
    Kibenge, Frederick S. B.
    Olsvik, Pal A.
    Penning, Louis C.
    Toegel, Stefan
    [J]. BMC MOLECULAR BIOLOGY, 2010, 11
  • [7] Why the need for qPCR publication guidelines?-The case for MIQE
    Bustin, Stephen A.
    [J]. METHODS, 2010, 50 (04) : 217 - 226
  • [8] The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments
    Bustin, Stephen A.
    Benes, Vladimir
    Garson, Jeremy A.
    Hellemans, Jan
    Huggett, Jim
    Kubista, Mikael
    Mueller, Reinhold
    Nolan, Tania
    Pfaffl, Michael W.
    Shipley, Gregory L.
    Vandesompele, Jo
    Wittwer, Carl T.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (04) : 611 - 622
  • [9] Improving biological relevancy of transcriptional biomarkers experiments by applying the MIQE guidelines to pre-clinical and clinical trials
    Dooms, M.
    Chango, A.
    Barbour, E.
    Pouillart, P.
    Nour, A. M. Abdel
    [J]. METHODS, 2013, 59 (01) : 147 - 153
  • [10] Fleige Simone, 2006, Molecular Aspects of Medicine, V27, P126, DOI 10.1016/j.mam.2005.12.003