An ultra-sensitive ratiometric fluorescent probe for hypochlorous acid detection by the synergistic effect of AIE and TBET and its application of detecting exogenous/endogenous HOCl in living cells

被引:42
作者
Duan, Qinya [1 ]
Zheng, Guansheng [1 ]
Li, Zejun [1 ]
Cheng, Ke [2 ,3 ,4 ]
Zhang, Jie [2 ,3 ,4 ]
Yang, Liu [2 ,3 ,4 ]
Jiang, Yin [1 ]
Zhang, Huatang [1 ]
He, Jun [1 ]
Sun, Hongyan [2 ,3 ,4 ]
机构
[1] Guangdong Univ Technol, Sch Chem Engn & Light Ind, Guangzhou 510006, Guangdong, Peoples R China
[2] City Univ Hong Kong, Dept Chem, Kowloon, 83 Tat Chee Ave, Hong Kong, Peoples R China
[3] City Univ Hong Kong, COSDAF, Kowloon, 83 Tat Chee Ave, Hong Kong, Peoples R China
[4] City Univ Hong Kong, Biotech & Hlth Ctr, Key Lab Biochip Technol, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
基金
中国国家自然科学基金;
关键词
LIVE-CELL; FAR-RED; MYELOPEROXIDASE; MECHANISMS; CANCER; MITOCHONDRIA; OXIDATION; DESIGN; ROLES; WATER;
D O I
10.1039/c9tb01279f
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
An ultra-sensitive and ratiometric fluorescent probe for hypochlorous acid (HOCl) detection based on the mechanism of aggregation induced emission (AIE) and through-bond energy transfer (TBET) has been reported herein. By exploiting the advantages of AIE and TBET, which eliminates emission leakage from dark donors, the probe exhibits ultra-high sensitivity towards HOCl by an enhancement of over 7000-fold in the fluorescence ratio (I-589 nm/I-477 nm), which is one of the highest recorded so far. The reaction mechanism has been discussed in detail, and the effects of interferents and the reaction kinetics have also been investigated. Lastly, the successful result of exogenous/endogenous HOCl imaging detection in different cell lines indicates the potential use of the probe in living systems.
引用
收藏
页码:5125 / 5131
页数:7
相关论文
共 35 条
  • [31] An HBT-Based Near-Infrared Fluorescent Probe for Colorimetric and Ratiometric Detection of Bisulfite and its Application in Living Cells
    Sun, Yuanchao
    Chen, Zhen
    Chen, Fengzao
    Liu, Heng
    He, Hanping
    Zhang, Xiuhua
    Wang, Shengfu
    JOURNAL OF FLUORESCENCE, 2017, 27 (04) : 1405 - 1411
  • [32] Two quenching groups are better than one: A robust strategy for constructing HOCl fluorescent probe with minimized background fluorescence and ultra-high sensitivity and its application of HOCl imaging in living cells and tissues
    Zheng, Guansheng
    Li, Zejun
    Duan, Qinya
    Cheng, Ke
    He, Yong
    Huang, Shumei
    Zhang, Huatang
    Jiang, Yin
    Jia, Yongguang
    Sun, Hongyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 310
  • [33] A bifunctional peptide-based fluorescent probe for ratiometric and "turn-on" detection of Zn(II) ions and its application in living cells
    Wang, Peng
    Wang, Qifan
    Guo, Zhouquan
    Xue, Shirui
    Chen, Bo
    Liu, Yi
    Ren, Wang
    Yang, Xiupei
    Wen, Shaohua
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 268
  • [34] A high-stable and fast-responsive lysosome-targeted probe for detection of endogenous and exogenous HClO in living cells and its application in zebrafish imaging
    Liu, Ying-Kun
    Cao, Jia-Xin
    Wang, Lin
    Liu, Tong-Guo
    Wang, Jian-Yong
    JOURNAL OF MOLECULAR STRUCTURE, 2024, 1316
  • [35] A highly sensitive "turn-on" dehydroabietic acid-based fluorescent probe for rapid sensing HSO3- and its application in sugar samples, living cells, and zebrafish
    LIU, Qing-Song
    CHEN, Lin-Lin
    WANG, Zhong-Long
    YANG, Zi-Hui
    SUN, Yue
    WANG, Shi-Fa
    GU, Wen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (08)