The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: Emerging Avenues and Challenges

被引:711
作者
Farina, Dario [1 ]
Jiang, Ning [1 ]
Rehbaum, Hubertus [1 ]
Holobar, Ales [2 ]
Graimann, Bernhard [3 ]
Dietl, Hans [3 ]
Aszmann, Oskar C. [4 ]
机构
[1] Univ Gottingen, Univ Med Ctr Gottingen, Bernstein Ctr Computat Neurosci, Dept Neurorehabil Engn,Bernstein Focus Neurotechn, D-37075 Gottingen, Germany
[2] Univ Maribor, Fac Elect Engn & Comp Sci, SLO-2000 Maribor, Slovenia
[3] Otto Bock HealthCare GmbH, D-37115 Duderstadt, Germany
[4] Med Univ Vienna, Div Plast & Reconstruct Surg, CD Lab Restorat Extrem Funct, Vienna, Austria
基金
欧洲研究理事会;
关键词
Motor unit; myoelectric control; neural drive to muscle; pattern recognition; regression; PROPORTIONAL MYOELECTRIC CONTROL; BRAIN-COMPUTER INTERFACES; PERIPHERAL NERVOUS-SYSTEM; HUMAN MOTOR UNITS; PATTERN-RECOGNITION; SENSORY FEEDBACK; CLASSIFICATION; ARM; ELECTROMYOGRAM; AMPUTEES;
D O I
10.1109/TNSRE.2014.2305111
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite not recording directly from neural cells, the surface electromyogram (EMG) signal contains information on the neural drive to muscles, i. e., the spike trains of motor neurons. Using this property, myoelectric control consists of the recording of EMG signals for extracting control signals to command external devices, such as hand prostheses. In commercial control systems, the intensity of muscle activity is extracted from the EMG and used for single degrees of freedom activation (direct control). Over the past 60 years, academic research has progressed to more sophisticated approaches but, surprisingly, none of these academic achievements has been implemented in commercial systems so far. We provide an overview of both commercial and academic myoelectric control systems and we analyze their performance with respect to the characteristics of the ideal myocontroller. Classic and relatively novel academic methods are described, including techniques for simultaneous and proportional control of multiple degrees of freedom and the use of individual motor neuron spike trains for direct control. The conclusion is that the gap between industry and academia is due to the relatively small functional improvement in daily situations that academic systems offer, despite the promising laboratory results, at the expense of a substantial reduction in robustness. None of the systems so far proposed in the literature fulfills all the important criteria needed for widespread acceptance by the patients, i. e. intuitive, closed-loop, adaptive, and robust real-time (200 ms delay) control, minimal number of recording electrodes with low sensitivity to repositioning, minimal training, limited complexity and low consumption. Nonetheless, in recent years, important efforts have been invested in matching these criteria, with relevant steps forwards.
引用
收藏
页码:797 / 809
页数:13
相关论文
共 109 条
[1]  
Almstrom C., 1977, ELECT CONTROL SYSTEM
[2]   Real-Time, Simultaneous Myoelectric Control Using Force and Position-Based Training Paradigms [J].
Ameri, Ali ;
Scheme, Erik J. ;
Kamavuako, Ernest Nlandu ;
Englehart, Kevin B. ;
Parker, Philip A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) :279-287
[3]  
Amsüss S, 2013, IEEE ENG MED BIO, P3622, DOI 10.1109/EMBC.2013.6610327
[4]  
[Anonymous], I LIMB ULTR US MAN
[5]  
Antfolk C, 2013, EXPERT REV MED DEVIC, V10, P45, DOI [10.1586/erd.12.68, 10.1586/ERD.12.68]
[6]   EMG-Based Control of a Robot Arm Using Low-Dimensional Embeddings [J].
Artemiadis, Panagiotis K. ;
Kyriakopoulos, Kostas J. .
IEEE TRANSACTIONS ON ROBOTICS, 2010, 26 (02) :393-398
[7]   Selective nerve transfers to improve the control of myoelectrical arm prostheses [J].
Aszmann, O. C. ;
Dietl, H. ;
Frey, M. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2008, 40 (01) :60-65
[8]  
Atkins DJ., 1996, J PROSTHET ORTHOT, V8, P2, DOI DOI 10.1097/00008526-199601000-00003
[9]  
Baikun Wan, 2010, 2010 IEEE International Conference on Robotics and Biomimetics (ROBIO), P1229, DOI 10.1109/ROBIO.2010.5723504
[10]   THE USE OF MYO-ELECTRIC CURRENTS IN THE OPERATION OF PROSTHESES [J].
BATTYE, CK ;
NIGHTINGALE, A ;
WHILLIS, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1955, 37 (03) :506-510