Feasibility study of low tube voltage (80 kVp) coronary CT angiography combined with contrast medium reduction using iterative model reconstruction (IMR) on standard BMI patients

被引:28
作者
Zhang, Fan [1 ]
Yang, Li [2 ]
Song, Xiang [2 ]
Li, Ying-Na [2 ]
Jiang, Yan [3 ]
Zhang, Xing-Hua [2 ]
Ju, Hai-Yue [2 ]
Wu, Jian [2 ]
Chang, Rui-Ping [2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, Hainan Branch, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, Beijing, Peoples R China
[3] Philips Healthcare, Clin Sci Imaging Syst, Shanghai, Peoples R China
基金
中国博士后科学基金;
关键词
CARDIOVASCULAR COMPUTED-TOMOGRAPHY; RADIATION-DOSE REDUCTION; IMAGE QUALITY; CARDIAC-CT; HYBRID; ALGORITHM; COMBINATION; PERFORMANCE; PROTOCOLS; SOCIETY;
D O I
10.1259/bjr.20150766
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the feasibility of low-tube-voltage (80kVp) coronary CT angiography (CCTA) combined with contrast medium (CM) reduction and iterative model reconstruction (IMR) on patients with standard body mass index compared with clinical routine protocol. Methods: Retrospectively gated helical CCTA scans were acquired using a 256-slice multi-slice CT (Brilliance iCT; Philips Healthcare, Cleveland, OH) on 94 patients with standard body mass index (20-25 kgm(-2)) who were randomly assigned into 2 groups. The scan protocol for Group 1 was 100kVp and 600mAs with 70 ml CM at an injection rate of 4.5-5.5 mls(-1); images were reconstructed by a hybrid iterative reconstruction technique (iDose(4); Philips Healthcare). Group 2 was scanned at 80kVp and 600mAs with 35 ml CM at an injection rate of 3.5-4.5 mls(-1); images were reconstructed with IMR. Objective measurements such as the mean image noise and contrast-to-noise ratio of the two groups were measured on CT images and compared using the paired t-test. In addition, a subjective image quality evaluation was performed by two radiologists who were blinded to the scan protocol, using a 5-point scale [1 (poor) to 5 (excellent)]. The results of the two groups were compared using Mann-Whitney U test. Results: The iodine delivery rate of Group 2 was 1.0 +/- 0.5 gls(-1) compared with 2.1 +/- 0.5 gls(-1) in Group 1 resulting in a reduction of 52.4%. In addition, an effective radiation dose reduction of 56.4% was achieved in Group 2 (2.4 +/- 1.2mSv) compared with Group 1 (5.5 +/- 1.4mSv). The mean CT attenuation, contrast-to-noise ratio and image quality of all segments in Group 2 were significantly improved compared with those in Group 1 (all, p<0.01). Conclusion: The use of IMR along with a low tube voltage (80kVp) combined with a low CM protocol for CCTA can reduce both radiation and CM dose with improved image quality. Advances in knowledge: In this study, we used a novel knowledge-based IMR which remarkably reduced the image noise. We compared the quality of the images obtained when the tube voltage was reduced to 80 kVp and that of those obtained according to the clinical routine protocols to determine whether ultra-low-dose imaging plus IMR is feasible in CCTA scans. We found that a low dose protocol combined with 80 kVp and reduced CM for CCTA can reduce both radiation dose and CM dosewith improved image quality by the use of IMR in non-obese patients.
引用
收藏
页数:9
相关论文
共 35 条
[11]   Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease [J].
Hou, Yang ;
Ma, Yue ;
Fan, Weipeng ;
Wang, Yuke ;
Yu, Mei ;
Vembar, Mani ;
Guo, Qiyong .
EUROPEAN RADIOLOGY, 2014, 24 (01) :3-11
[12]   Comparisons of Image Quality and Radiation Dose Between Iterative Reconstruction and Filtered Back Projection Reconstruction Algorithms in 256-MDCT Coronary Angiography [J].
Hou, Yang ;
Liu, Xin ;
Xv, Shu ;
Guo, Wenli ;
Guo, Qiyong .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) :588-594
[13]   Reduction in radiation and contrast medium dose via optimization of low-kilovoltage CT protocols using a hybrid iterative reconstruction algorithm at 256-slice body CT: Phantom study and clinical correlation [J].
Itatani, R. ;
Oda, S. ;
Utsunomiya, D. ;
Funama, Y. ;
Honda, K. ;
Katahira, K. ;
Morishita, S. ;
Yamamura, S. ;
Namimoto, T. ;
Yamashita, Y. .
CLINICAL RADIOLOGY, 2013, 68 (03) :E128-E135
[14]   Renal toxicity evaluation and comparison between visipaque (iodixanol) and hexabrix (ioxaglate) in patients with renal insufficiency undergoing coronary angiography - The RECOVER study: A randomized controlled trial [J].
Jo, Sang-Ho ;
Youn, Tae-Jin ;
Koo, Bon-Kwon ;
Park, Jim-Shik ;
Kang, Hyun-Jae ;
Cho, Young-Seok ;
Chung, Woo-Young ;
Joo, Gwon-Wook ;
Chae, In-Ho ;
Choi, Dong-Ju ;
Oh, Byung-Hee ;
Lee, Myoung-Mook ;
Park, Young-Bae ;
Kim, Hyo-Soo .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (05) :924-930
[15]   Impact of Increasing Levels of Advanced Iterative Reconstruction on Image Quality in Low-Dose Cardiac CT Angiography [J].
Kroepil, P. ;
Bigdeli, A. H. ;
Nagel, H. D. ;
Antoch, G. ;
Cohnen, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06) :567-575
[16]   SCCT guidelines for the interpretation and reporting of coronary CT angiography: A report of the Society of Cardiovascular Computed Tomography Guidelines Committee [J].
Leipsic, Jonathon ;
Abbara, Suhny ;
Achenbach, Stephan ;
Cury, Ricardo ;
Earls, James P. ;
Mancini, G. B. John ;
Nieman, Koen ;
Pontone, Gianluca ;
Raff, Gilbert L. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (05) :342-358
[17]   Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :655-660
[18]   Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :649-654
[19]   Optimizing Contrast Media Injection Protocols in State-of-the Art Computed Tomographic Angiography [J].
Lell, Michael M. ;
Jost, Gregor ;
Korporaal, Johannes Georg ;
Mahnken, Andreas Horst ;
Flohr, Thomas G. ;
Uder, Michael ;
Pietsch, Hubertus .
INVESTIGATIVE RADIOLOGY, 2015, 50 (03) :161-167
[20]   Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels [J].
Love, A. ;
Olsson, M-L ;
Siemund, R. ;
Stalhammar, F. ;
Bjorkman-Burtscher, I. M. ;
Soderberg, M. .
BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031)