Binding and detachment dynamics of microbubbles targeted to P-selectin under controlled shear flow

被引:195
作者
Takalkar, AM
Klibanov, AL
Rychak, JJ
Lindner, JR
Ley, K
机构
[1] Univ Virginia Hlth Syst, Cardiovasc Res Ctr, Charlottesville, VA 22908 USA
[2] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Internal Med, Div Cardiovasc, Charlottesville, VA 22903 USA
关键词
ultrasound contrast; targeting; microbubbles; adhesion; P-selectin;
D O I
10.1016/j.jconrel.2004.03.002
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study was performed to assess the binding kinetics of a targeted microbubble contrast agent exposed to shear stress. An ultrasound contrast targeted to P-selectin was designed by conjugating monoclonal antibodies against murine P-selectin (RB40.34) to the lipid monolayer shell of the microbubble using poly(ethylene glycol)-biotin-streptavidin. The attachment and detachment of targeted microbubbles to P-selectin immobilized on a culture dish were assessed in a parallel-plate flow chamber. Targeted microbubbles (5 x 10(6) particles/ml) drawn through the flow chamber coated with P-selectin (109 sites/mum(2)) at a shear stress of 0.3 dyn/cm(2) accumulated at a rate of 565 mm(-2) min(-1). Attachment rates increased at higher plate surface densities of P-selectin, and microbubble detachment was reduced. Accumulation rate first increased with shear stress, reached a maximum at similar to0.6 dyn/cm(2) and then decreased. Control experiments on a plate that lacked P-selectin, or was blocked with mAb RB40.34, resulted in minimal bubble attachment. Microbubble detachment was tested by ramping up shear stress at 30-s intervals. Half-maximal detachment was reached at 34 dyn/cm(2). Overall, accumulation and retention of targeted ultrasound contrast agents is possible under physiologic flow conditions and is strongly influenced by shear stress and surface density of the target receptor. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:473 / 482
页数:10
相关论文
共 34 条
[1]  
[Anonymous], BIOCH J
[2]   Ultrasound-targeted microbubble destruction can repeatedly direct highly specific plasmid expression to the heart [J].
Bekeredjian, R ;
Chen, SY ;
Frenkel, PA ;
Grayburn, PA ;
Shohet, RV .
CIRCULATION, 2003, 108 (08) :1022-1026
[3]   Ligand coated nanosphere adhesion to E- and P-selectin under static and flow conditions [J].
Blackwell, JE ;
Dagia, NM ;
Dickerson, JB ;
Berg, EL ;
Goetz, DJ .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (06) :523-533
[4]   ONLY SIMULTANEOUS BLOCKING OF THE L-SELECTIN AND P-SELECTIN COMPLETELY INHIBITS NEUTROPHIL MIGRATION INTO MOUSE PERITONEUM [J].
BOSSE, R ;
VESTWEBER, D .
EUROPEAN JOURNAL OF IMMUNOLOGY, 1994, 24 (12) :3019-3024
[5]   Optimization of ultrasound parameters for cardiac gene delivery of adenoviral or plasmid deoxyribonucleic acid by ultrasound-targeted microbubble destruction [J].
Chen, SY ;
Shohet, RV ;
Bekeredjian, R ;
Frenkel, P ;
Grayburn, PA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (02) :301-308
[6]   Noninvasive imaging of myocardial reperfusion injury using leukocyte-targeted contrast echocardiography [J].
Christiansen, JP ;
Leong-Poi, H ;
Klibanov, AL ;
Kaul, S ;
Lindner, JR .
CIRCULATION, 2002, 105 (15) :1764-1767
[7]   Surface treatments of polymers for biocompatibility [J].
Elbert, DL ;
Hubbell, JA .
ANNUAL REVIEW OF MATERIALS SCIENCE, 1996, 26 :365-394
[8]   Isolated P-selectin glycoprotein ligand-1 dynamic adhesion to P- and E-selectin [J].
Goetz, DJ ;
Greif, DM ;
Ding, H ;
Camphausen, RT ;
Howes, S ;
Comess, KM ;
Snapp, KR ;
Kansas, GS ;
Luscinskas, FW .
JOURNAL OF CELL BIOLOGY, 1997, 137 (02) :509-519
[9]  
HERMANSON GT, 1996, BIOCONJUGATE TECHNIQ, P382
[10]   PHOTON-CORRELATION SPECTROSCOPY OF HUMAN-IGG [J].
JOSSANG, T ;
FEDER, J ;
ROSENQVIST, E .
JOURNAL OF PROTEIN CHEMISTRY, 1988, 7 (02) :165-171