A comparison of nasal trauma in preterm infants extubated to either heated humidified high-flow nasal cannulae or nasal continuous positive airway pressure

被引:72
作者
Collins, C. L. [1 ]
Barfield, C. [1 ]
Horne, R. S. C. [2 ]
Davis, P. G. [3 ]
机构
[1] Mercy Hosp Women, Melbourne, Vic, Australia
[2] Monash Univ, Monash Inst Med Res, Ritchie Ctr, Melbourne, Vic 3004, Australia
[3] Royal Womens Hosp, Melbourne, Vic, Australia
关键词
Nasal trauma; NCPAP; High-flow nasal cannulae; INJURY; CPAP;
D O I
10.1007/s00431-013-2139-8
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The objectives of this study were (1) to devise a nasal trauma score for preterm infants receiving non-invasive respiratory support, (2) to compare the incidence of nasal trauma in preterm infants < 32 weeks gestation randomised to either nasal continuous positive airway pressure (NCPAP) or heated humidified high-Flow nasal cannulae (HHHFNC), in the first 7 days post-extubation and (3) to assess the effect of two different nasal dressings in those assigned to NCPAP. We randomly assigned preterm ventilated infants to receive VapothermA (R) HHHFNC or NCPAP post-extubation. Infants receiving HHHFNC were treated with Sticky WhiskersA (R) and infants receiving NCPAP received either Sticky WhiskersA (R) or CannualaideA (R) nasal dressings. Bedside nursing staff scored six sites on each infant's nose for erythema, bleeding or ulceration. Scores were recorded three times daily for the first 7 days post-extubation. The sum of these 21 scores was used as the summary measure of nasal trauma. The mean nasal trauma score for infants assigned HHHFNC was 2.8 (SD 5.7) compared to 11.7 for NCPAP (SD 10.4), p < 0.001. There was no difference in mean trauma score between infants on NCPAP assigned Sticky WhiskersA (R) 14.4 (SD 12.5) or CannualaideA (R) 9.5 (SD 7.3), p = 0.06. Conclusion: HHHFNC resulted in significantly less nasal trauma in the first 7 days post-extubation than NCPAP and was most significant in infants < 28 weeks of gestation. The use of protective dressings was not associated with decreased nasal trauma for infants on NCPAP.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [21] High-flow nasal cannula as a device to provide continuous positive airway pressure in infants
    Spence, K. L.
    Murphy, D.
    Kilian, C.
    McGonigle, R.
    Kilani, R. A.
    JOURNAL OF PERINATOLOGY, 2007, 27 (12) : 772 - 775
  • [22] High-flow nasal cannula as a device to provide continuous positive airway pressure in infants
    K L Spence
    D Murphy
    C Kilian
    R McGonigle
    R A Kilani
    Journal of Perinatology, 2007, 27 : 772 - 775
  • [23] High-Flow Nasal Cannulae for Respiratory Support of Preterm Infants: A Review of the Evidence
    Manley, Brett J.
    Dold, Simone K.
    Davis, Peter G.
    Roehr, Charles C.
    NEONATOLOGY, 2012, 102 (04) : 300 - 308
  • [24] Comparison of a high-flow humidified nasal cannula to nasal continuous positive airway pressure in children with acute bronchiolitis: experience in a pediatric intensive care unit
    Metge, Prune
    Grimaldi, Celine
    Hassid, Sophie
    Thomachot, Laurent
    Loundou, Anderson
    Martin, Claude
    Michel, Fabrice
    EUROPEAN JOURNAL OF PEDIATRICS, 2014, 173 (07) : 953 - 958
  • [25] Evidence Support and Guidelines for Using Heated, Humidified, High-Flow Nasal Cannulae in Neonatology Oxford Nasal High-Flow Therapy Meeting, 2015
    Roehr, Charles C.
    Yoder, Bradley A.
    Davis, Peter G.
    Ives, Kevin
    CLINICS IN PERINATOLOGY, 2016, 43 (04) : 693 - +
  • [26] Heated humidified high-flow nasal cannula versus nasal continuous positive airways pressure for respiratory support in preterm neonates - A noninferiority trial at a tertiary care center
    Charki, Siddu
    Patil, Priyanka Keval
    Hadalgi, Laxmi
    Kulkarni, Trimal
    Loni, Ramaning
    Karva, M. M.
    Bidari, Laxman H.
    JOURNAL OF CLINICAL NEONATOLOGY, 2020, 9 (03) : 168 - 174
  • [27] Comparison of Two Methods for Weaning from Nasal Continuous Positive Airway Pressure via the Cyclic Use of High-Flow Nasal Cannula or Room Air in Preterm Infants
    Yang, Shu-Ting
    Chung, Hao-Wei
    Chen, Hsiu-Lin
    CHILDREN-BASEL, 2024, 11 (03):
  • [28] A Comparative Study between Postextubation of Preterm Neonates into High-Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure
    Morsy, Ramy Saleh
    Badawy, Magda Mahmooud Sedky
    Said, Reem Nabil
    Ali, Aliaa Adel
    Abuelhamd, Walaa Alsharany
    IRANIAN JOURNAL OF NEONATOLOGY, 2021, 12 (01) : 12 - 19
  • [29] A randomized pilot study comparing heated humidified high-flow nasal cannulae with NIPPV for RDS
    Kugelman, Amir
    Riskin, Arieh
    Said, Waseem
    Shoris, Irit
    Mor, Frida
    Bader, David
    PEDIATRIC PULMONOLOGY, 2015, 50 (06) : 576 - 583
  • [30] Work of breathing indices in infants with respiratory insufficiency receiving high-flow nasal cannula and nasal continuous positive airway pressure
    de Jongh, B. E.
    Locke, R.
    Mackley, A.
    Emberger, J.
    Bostick, D.
    Stefano, J.
    Rodriguez, E.
    Shaffer, T. H.
    JOURNAL OF PERINATOLOGY, 2014, 34 (01) : 27 - 32