Re-examination of the cadmium reduction method and optimisation of conditions for the determination of nitrate by flow injection analysis

被引:55
作者
Gal, C
Frenzel, W
Möller, J
机构
[1] Tech Univ Berlin, Inst Tech Umweltschutz, Facgebiet Luftreinhaltung, D-10623 Berlin, Germany
[2] Foss Tecator AB, SE-26321 Hoganas, Sweden
关键词
nitrate determination; cadmium reduction method; flow injection analysis;
D O I
10.1007/s00604-004-0193-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper re-examines the widely used flow injection method for nitrate which is based on heterogeneous reduction of nitrate with copperized cadmium followed by spectrophotometric detection of nitrite formed. The thorough investigation presented here has shown that the reduction step is very critical as far as conversion rate, possible further reduction of nitrite and long-term stability of the reductor column is concerned. The reasons for inconsistent and irreproducible results mentioned in original papers and often obtained in routine applications could be traced back to the way the reductor material had been prepared, the chemical conditions under which reduction takes place (i.e. pH and concentration of complexing agents) and the poisoning of the cadmium surface by sample constituents. The concomitant reduction of dissolved oxygen has been identified as a potential problem causing loss of pH control (due to in-situ generation of hydroxide). De-oxygenation of the carrier solution was found to be a means to overcome this problem with the additional advantages of increasing the lifetime of the reductor column and significantly reducing the concentration of cadmium ions in the waste stream. The role of particle size and column dimension as well as sample residence time within the reductor column on reduction efficiency and sample dispersion has also been investigated.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 31 条
[2]  
[Anonymous], 2005, STANDARD METHODS EXA, V21
[3]  
[Anonymous], GIT LABOR FACHZ
[4]  
[Anonymous], 1996, 13395 ISO
[5]   CONFIGURATION WITH INTERNALLY COUPLED VALVES TO OVERCOME SHORTCOMINGS IN THE SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY FLOW-INJECTION ANALYSIS [J].
BERMUDEZ, B ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1988, 35 (10) :810-812
[6]   AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF NITRATE [J].
CLINCH, JR ;
WORSFOLD, PJ ;
CASEY, H .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :523-531
[7]  
CROMPTON TR, 1997, DETERMINATION ANIONS
[8]   COMPARISON OF DIFFERENT FORMS OF CADMIUM AS REDUCING AGENTS FOR BATCH DETERMINATION OF NITRATE [J].
DAVISON, W ;
WOOF, C .
ANALYST, 1978, 103 (1225) :403-406
[9]   Oxidative detection of nitrite at an electrocatalytic [Rut(bipy)(2)poly-(4-vinylpyridine)(10)Cl]Cl electrochemical sensor applied for the flow injection determination of nitrate using a Cu/Cd reductor column [J].
Doherty, AP ;
Stanley, MA ;
Leech, D ;
Vos, JG .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :111-120
[10]   A novel FIA configuration for the simultaneous determination of nitrate and nitrite and its use for monitoring an urban waste water treatment plant based on N/D criteria [J].
Gabriel, D ;
Baeza, J ;
Valero, F ;
Lafuente, J .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :173-183