Navigated total knee arthroplasty: is it error-free?

被引:14
|
作者
Chua, Kerk Hsiang Zackary [1 ]
Chen, Yongsheng [1 ]
Lingaraj, Krishna [1 ]
机构
[1] Natl Univ Hlth Syst, Div Hip & Knee Surg, Singapore 119228, Singapore
关键词
Computer navigation; Total knee arthroplasty; Alignment deviation; Positioning error; Bone resection; Implant position; COMPUTER-ASSISTED NAVIGATION; CUTTING ERRORS; REPLACEMENT; ALIGNMENT; SURGERY; SYSTEM; IMPLANTATION; TKA;
D O I
10.1007/s00167-013-2641-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study was to determine whether errors do occur in navigated total knee arthroplasty (TKAs) and to study whether errors in bone resection or implantation contribute to these errors. Methods A series of 20 TKAs was studied using computer navigation. The coronal and sagittal alignments of the femoral and tibial cutting guides, the coronal and sagittal alignments of the final tibial implant and the coronal alignment of the final femoral implant were compared with that of the respective bone resections. To determine the post-implantation mechanical alignment of the limb, the coronal alignment of the femoral and tibial implants was combined. Results The median deviation between the femoral cutting guide and bone resection was 0 degrees (range -0.5 degrees to +0.5 degrees) in the coronal plane and 1.0 degrees (range -2.0 degrees to +1.0 degrees) in the sagittal plane. The median deviation between the tibial cutting guide and bone resection was 0.5 degrees (range -1.0 degrees to +1.5 degrees) in the coronal plane and 1.0 degrees (range -1.0 degrees to +3.5 degrees) in the sagittal plane. The median deviation between the femoral bone resection and the final implant was 0.25 degrees (range -2.0 degrees to 3.0 degrees) in the coronal plane. The median deviation between the tibial bone resection and the final implant was 0.75 degrees (range -3.0 degrees to +1.5 degrees) in the coronal plane and 1.75 degrees (range -4.0 degrees to +2.0 degrees) in the sagittal plane. The median post-implantation mechanical alignment of the limb was 0.25 degrees (range -3.0 degrees to +2.0 degrees). Conclusions When navigation is used only to guide the positioning of the cutting jig, errors may arise in the manual, non-navigated steps of the procedure. Our study showed increased cutting errors in the sagittal plane for both the femur and the tibia, and following implantation, the greatest error was seen in the sagittal alignment of the tibial component. Computer navigation should be used not only to guide the positioning of the cutting jig, but also to check the bone resection and implant position during TKA. Level of evidence IV.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [21] Femur Positioning in Navigated Total Knee Arthroplasty
    Pfitzner, Tilman
    Roehner, Eric
    Preininger, Bernd
    Perka, Carsten
    Matziolis, Georg
    ORTHOPEDICS, 2012, 35 (10) : 45 - 49
  • [22] Technical and surgical causes of outliers after computer navigated total knee arthroplasty
    Shah, Siddharth M.
    Sciberras, Nadia C.
    Allen, David J.
    Picard, Frederic
    JOURNAL OF ORTHOPAEDICS, 2020, 18 : 171 - 176
  • [23] Low Incidence of Postoperative Complications With Navigated Total Knee Arthroplasty
    Brown, Matthew J.
    Matthews, John R.
    Bayers-Thering, Mary T.
    Phillips, Matthew J.
    Krackow, Kenneth A.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (07) : 2120 - 2126
  • [24] Columbus® computer navigated total knee arthroplasty: Gap balancing versus measured resection
    Clement, N. D.
    Makaram, N.
    Bell, J.
    Tiemessen, C. H.
    Mehdi, S. A.
    Livingston, S. J.
    KNEE, 2017, 24 (06) : 1442 - 1447
  • [25] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Ko, Jae Han
    Han, Chang Dong
    Shin, Kyoo Ho
    Nguku, Levis
    Yang, Ick Hwan
    Lee, Woo Suk
    Kim, Kwang Il
    Park, Kwan Kyu
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2476 - 2482
  • [26] Adjustable Cutting Blocks for Computer-Navigated Total Knee Arthroplasty A Cadaver Study
    Koulalis, Dimitrios
    O'Loughlin, Padhraig F.
    Plaskos, Christopher
    Kendoff, Daniel
    Pearle, Andrew D.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (05) : 807 - 811
  • [27] Extension and Flexion Gap Balancing and Its Correlation With Alignment in Navigated Total Knee Arthroplasty
    Debieux, Pedro
    Lemos Marques de Oliveira, Jose Renato
    da Silveira Franciozi, Carlos Eduardo
    Kubota, Marcelo Seiji
    Granata, Geraldo, Jr.
    Malheiros Luzo, Marcus Vinicius
    ORTHOPEDICS, 2014, 37 (08) : e685 - e691
  • [28] Computer Navigated Versus Conventional Total Knee Arthroplasty
    Tolk, Jaap J.
    Koot, Henk W. J.
    Janssen, Rob P. A.
    JOURNAL OF KNEE SURGERY, 2012, 25 (04) : 347 - 352
  • [29] Image-guided total knee arthroplasty
    Hambright, D. S.
    Severson, E. P.
    Rachala, S. R.
    Bolognesi, M. P.
    Browne, J. A.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2010, 61 (03) : 183 - 202
  • [30] Navigated Unicompartmental Knee Arthroplasty: A Different Perspective
    Malhotra, Rajesh
    Gupta, Saurabh
    Gupta, Vivek
    Manhas, Vikrant
    CLINICS IN ORTHOPEDIC SURGERY, 2021, 13 (04) : 491 - 498