Navigated total knee arthroplasty: is it error-free?

被引:14
作者
Chua, Kerk Hsiang Zackary [1 ]
Chen, Yongsheng [1 ]
Lingaraj, Krishna [1 ]
机构
[1] Natl Univ Hlth Syst, Div Hip & Knee Surg, Singapore 119228, Singapore
关键词
Computer navigation; Total knee arthroplasty; Alignment deviation; Positioning error; Bone resection; Implant position; COMPUTER-ASSISTED NAVIGATION; CUTTING ERRORS; REPLACEMENT; ALIGNMENT; SURGERY; SYSTEM; IMPLANTATION; TKA;
D O I
10.1007/s00167-013-2641-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study was to determine whether errors do occur in navigated total knee arthroplasty (TKAs) and to study whether errors in bone resection or implantation contribute to these errors. Methods A series of 20 TKAs was studied using computer navigation. The coronal and sagittal alignments of the femoral and tibial cutting guides, the coronal and sagittal alignments of the final tibial implant and the coronal alignment of the final femoral implant were compared with that of the respective bone resections. To determine the post-implantation mechanical alignment of the limb, the coronal alignment of the femoral and tibial implants was combined. Results The median deviation between the femoral cutting guide and bone resection was 0 degrees (range -0.5 degrees to +0.5 degrees) in the coronal plane and 1.0 degrees (range -2.0 degrees to +1.0 degrees) in the sagittal plane. The median deviation between the tibial cutting guide and bone resection was 0.5 degrees (range -1.0 degrees to +1.5 degrees) in the coronal plane and 1.0 degrees (range -1.0 degrees to +3.5 degrees) in the sagittal plane. The median deviation between the femoral bone resection and the final implant was 0.25 degrees (range -2.0 degrees to 3.0 degrees) in the coronal plane. The median deviation between the tibial bone resection and the final implant was 0.75 degrees (range -3.0 degrees to +1.5 degrees) in the coronal plane and 1.75 degrees (range -4.0 degrees to +2.0 degrees) in the sagittal plane. The median post-implantation mechanical alignment of the limb was 0.25 degrees (range -3.0 degrees to +2.0 degrees). Conclusions When navigation is used only to guide the positioning of the cutting jig, errors may arise in the manual, non-navigated steps of the procedure. Our study showed increased cutting errors in the sagittal plane for both the femur and the tibia, and following implantation, the greatest error was seen in the sagittal alignment of the tibial component. Computer navigation should be used not only to guide the positioning of the cutting jig, but also to check the bone resection and implant position during TKA. Level of evidence IV.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 32 条
[11]   Alignments and clinical results in conventional and navigated total knee arthroplasty [J].
Ensini, A. ;
Catani, F. ;
Leardini, A. ;
Romagnoli, M. ;
Giannini, S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (457) :156-162
[12]  
Fehring TK, 2001, CLIN ORTHOP RELAT R, P315
[13]   Alignment outcomes in navigated total knee arthroplasty: a meta-analysis [J].
Fu, Yonghui ;
Wang, Mingming ;
Liu, Yifeng ;
Fu, Qin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (06) :1075-1082
[14]   Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system [J].
Hasegawa, Masahiro ;
Yoshida, Kakunoshin ;
Wakabayashi, Hiroki ;
Sudo, Akihiro .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (01) :27-30
[15]  
Hepinstall Matthew S, 2010, HSS J, V6, P138, DOI 10.1007/s11420-009-9150-7
[16]   Precision in orthopaedic computer navigation [J].
Hüfner T. ;
Kendoff D. ;
Citak M. ;
Geerling J. ;
Krettek C. .
Der Orthopäde, 2006, 35 (10) :1043-1055
[17]   Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system - A case-control study of 235 cases compared with 235 conventionally implanted prostheses [J].
Jenny, JY ;
Clemens, U ;
Kohler, S ;
Kiefer, H ;
Konermann, W ;
Miehlke, RK .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :832-839
[18]   Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty [J].
Kim, Tae Kyun ;
Chang, Chong Bum ;
Kang, Yeon Gwi ;
Chung, Byung June ;
Cho, Hyung Joon ;
Seong, Sang Cheol .
KNEE, 2010, 17 (01) :23-28
[19]  
Koyonos Loukas, 2009, Orthopedics, V32, P317
[20]   Computer-assisted navigation in TKA -: Where we are and where we are going [J].
Laskin, Richard S. ;
Beksac, Burak .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :127-131