Navigated total knee arthroplasty: is it error-free?

被引:14
作者
Chua, Kerk Hsiang Zackary [1 ]
Chen, Yongsheng [1 ]
Lingaraj, Krishna [1 ]
机构
[1] Natl Univ Hlth Syst, Div Hip & Knee Surg, Singapore 119228, Singapore
关键词
Computer navigation; Total knee arthroplasty; Alignment deviation; Positioning error; Bone resection; Implant position; COMPUTER-ASSISTED NAVIGATION; CUTTING ERRORS; REPLACEMENT; ALIGNMENT; SURGERY; SYSTEM; IMPLANTATION; TKA;
D O I
10.1007/s00167-013-2641-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study was to determine whether errors do occur in navigated total knee arthroplasty (TKAs) and to study whether errors in bone resection or implantation contribute to these errors. Methods A series of 20 TKAs was studied using computer navigation. The coronal and sagittal alignments of the femoral and tibial cutting guides, the coronal and sagittal alignments of the final tibial implant and the coronal alignment of the final femoral implant were compared with that of the respective bone resections. To determine the post-implantation mechanical alignment of the limb, the coronal alignment of the femoral and tibial implants was combined. Results The median deviation between the femoral cutting guide and bone resection was 0 degrees (range -0.5 degrees to +0.5 degrees) in the coronal plane and 1.0 degrees (range -2.0 degrees to +1.0 degrees) in the sagittal plane. The median deviation between the tibial cutting guide and bone resection was 0.5 degrees (range -1.0 degrees to +1.5 degrees) in the coronal plane and 1.0 degrees (range -1.0 degrees to +3.5 degrees) in the sagittal plane. The median deviation between the femoral bone resection and the final implant was 0.25 degrees (range -2.0 degrees to 3.0 degrees) in the coronal plane. The median deviation between the tibial bone resection and the final implant was 0.75 degrees (range -3.0 degrees to +1.5 degrees) in the coronal plane and 1.75 degrees (range -4.0 degrees to +2.0 degrees) in the sagittal plane. The median post-implantation mechanical alignment of the limb was 0.25 degrees (range -3.0 degrees to +2.0 degrees). Conclusions When navigation is used only to guide the positioning of the cutting jig, errors may arise in the manual, non-navigated steps of the procedure. Our study showed increased cutting errors in the sagittal plane for both the femur and the tibia, and following implantation, the greatest error was seen in the sagittal alignment of the tibial component. Computer navigation should be used not only to guide the positioning of the cutting jig, but also to check the bone resection and implant position during TKA. Level of evidence IV.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 32 条
[1]   Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[2]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]   Intraoperative cutting errors in total knee arthroplasty [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Perlick, C ;
Lüring, C ;
Grifka, J .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (01) :16-20
[4]   The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect? [J].
Biant, Leela C. ;
Yeoh, Kwan ;
Walker, Peter M. ;
Bruce, Warwick J. M. ;
Walsh, William R. .
KNEE, 2008, 15 (03) :238-241
[5]   Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[6]   Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk? [J].
Bove, J. -C. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (05) :536-542
[7]   Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty [J].
Catani, Fabio ;
Biasca, Nicola ;
Ensini, Andrea ;
Leardini, Alberto ;
Bianchi, Luca ;
Digennaro, Vitantonio ;
Giannini, Sandro .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :765-771
[8]   Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol) [J].
Chauhan, SK ;
Clark, GW ;
Lloyd, S ;
Scott, RG ;
Breidahl, W ;
Sikorski, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :818-823
[9]   Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[10]   Mini-incision total knee arthroplasty can increase risk of component malalignment [J].
Dalury, DF ;
Dennis, DA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :77-81