Detection and experimental investigation of open conductor and single-phase earth return faults in distribution systems

被引:9
|
作者
Esmail, Ehab M. [1 ]
Elgamasy, Mahmoud M. [2 ]
Kawady, Tamer A. [2 ]
Taalab, Abdel-Maksoud, I [2 ]
Elkalashy, Nagy, I [2 ]
Elsadd, Mahmoud A. [3 ]
机构
[1] Scince Valley Acad, Valley High Inst Engn & Technol, El Obour 11828, Egypt
[2] Menoufia Univ, Elect Engn Dept, Fac Engn, Shibin Al Kawm 32511, Egypt
[3] Damanhour Univ, Elect Engn Dept, Fac Engn, Damanhour, Egypt
关键词
Simultaneous fault; Single-phase return fault; MV distribution feeder; PROTECTION; LOCATION;
D O I
10.1016/j.ijepes.2022.108089
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new and reliable detection approach for different crucial faults in distribution systems. These faults are one-open conductor faults at the far side of the feeder or simultaneous faults that are an open conductor followed by an earth fault at either the source side or load side (downed conductor-return faults). Under downed conductor-return faults, there is no zero-sequence current at the conventional protection point. Furthermore, the negative-sequence component is less than the normal unbalance component of the conventional protection point under one-open conductor faults at the far side of the feeder. Therefore, the presented detection approach is based on the measurements at the low voltage side of the load transformers. The proposed method detects such faults by monitoring only the magnitude of the measured three-phase voltage at the load side without installing voltage transformers. A robust threshold value is proposed to guarantee dependability against all fault conditions and security against the normal unbalance. Also, the security of the proposed approach against external faults (at the low voltage side) is verified by monitoring the magnitude of the threephase current. Fortunately, the proposed system identifies the faulted section. The faulted feeder isolation and the faulted section isolation are accomplished by a proposed autonomous control method with the aid of the infrastructure of smart grids (available communication system). Extensive investigations are done based on a detailed simulation of the selected distribution feeder using the ATP-EMTP program. For verification purposes, recorded faulted cases are experimentally applied on a real distribution feeder to visualize such fault conditions and confirm the detection impossibility of earth-return faults by conventional protection, significantly if the fault faraway the substation. On the other hand, all applied test results corroborate the efficacy of the proposed detection method under the considered faults.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Experimental investigation on the single-phase flow friction in narrow annulus
    Lu, Guang-Yao
    Sun, Zhong-Ning
    Wang, Jing
    Yan, Chang-Qi
    Hedongli Gongcheng/Nuclear Power Engineering, 2006, 27 (03): : 28 - 31
  • [22] Experimental investigation of single-phase flow in structured packing by LDV
    Chen Jiangbo
    Liu Chunjiang
    Li Yingke
    Huang, Ying
    Yuan Xigang
    Yu Guocong
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2007, 15 (06) : 821 - 827
  • [23] Experimental investigation of a single-phase UPQC with minimum VA loading
    Kolhatkar, Yashomani Y.
    Das, Shyama P.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 373 - 380
  • [24] Mathematical Modeling of New Algorithms for Single-Phase Earth Faults Protection in a Compensated Electrical Network
    Syvokobylenko, V. F.
    Lysenko, V. A.
    PROBLEMELE ENERGETICII REGIONALE, 2019, (1-2): : 1 - 11
  • [25] ASSESSMENT OF SELECTIVITY OF PROTECTION DEVICES AGAINST SINGLE-PHASE EARTH FAULTS IN 6 (10) KV
    Rogov, P. A.
    JOURNAL OF MINING INSTITUTE, 2009, 182 : 100 - 104
  • [26] Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data
    Ashok, Kavya
    Li, Dan
    Gebraeel, Nagi
    Divan, Deepak
    IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (06) : 5073 - 5083
  • [27] Temporary overvoltages in high-voltage power systems caused by breaks of circuit continuity during single-phase earth faults
    Tarko, Rafal
    Nowak, Wieslaw
    Szpyra, Waldemar
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (04) : 628 - 634
  • [28] Experimental set-up to study power quality in single-phase split-phase distribution systems
    Vicente I.
    Arrinda A.
    Rodríguez-Seco J.E.
    Piyasinghe L.
    Renewable Energy and Power Quality Journal, 2023, 21 : 143 - 148
  • [29] Continuous Operation of Smart Transformer-fed Distribution Grid with Single-phase Faults
    Zhu, Rongwu
    Liserre, Marco
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 458 - 464
  • [30] A Single-Phase Phasor Measurement Unit for Smart Distribution Systems
    Wei Yu
    Chen Yuchen
    Wang Kai
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,