Influence of magnetic field on the seismometer in vibration correction for atom gravimeters

被引:4
作者
Qi, Kun
Xu, Yao-Yao [1 ]
Deng, Xiao-Bing
Chen, Le-Le
Luo, Qin
Zhou, Min-Kang
Duan, Xiao-Chun
Hu, Zhong-Kun
机构
[1] Huazhong Univ Sci & Technol, MOE Key Lab Fundamental Phys Quant Measurement, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
INTERFEROMETER; ACCELERATION; GRAVITY;
D O I
10.1063/5.0081148
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Vibration correction provides a simple and flexible method of suppressing ambient vibration noise in transportable atom gravimeters. However, in the seismometers used for vibration correction, a spurious output may be induced by the magnetic field of the magnetic-optical trap, introducing errors to the gravity measurements. This paper evaluates the influence of the magnetic field on the seismometer and the corresponding errors in the gravity measurements. It is found that an error level of order 10 mu Gal may be present if the seismometer is not configured carefully. The dependence of the influence on the orientation of the seismometer and the lasting time of the magnetic field are investigated. The effective suppression of the influence by shielding the seismometer is also demonstrated. Our results focus attention on the possible errors related to seismometers in high-precision gravity measurements by using atom gravimeters.& nbsp;& nbsp;Published under an exclusive license by AIP Publishing.
引用
收藏
页数:6
相关论文
共 37 条
[1]  
Ackerley N., 2015, PRINCIPLES BROADBAND
[2]   Compact cold atom gravimeter for field applications [J].
Bidel, Yannick ;
Carraz, Olivier ;
Charriere, Renee ;
Cadoret, Malo ;
Zahzam, Nassim ;
Bresson, Alexandre .
APPLIED PHYSICS LETTERS, 2013, 102 (14)
[3]   Note: Effect of the parasitic forced vibration in an atom gravimeter [J].
Chen, Le-Le ;
Luo, Qin ;
Zhang, Heng ;
Duan, Xiao-Chun ;
Zhou, Min-Kang ;
Hu, Zhong-Kun .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (06)
[4]   Low frequency vertical geometric anti-spring vibration isolators [J].
Chin, EJ ;
Lee, KT ;
Winterflood, J ;
Ju, L ;
Blair, DG .
PHYSICS LETTERS A, 2005, 336 (2-3) :97-105
[5]   Underground operation at best sensitivity of the mobile LNE-SYRTE cold atom gravimeter [J].
Farah T. ;
Guerlin C. ;
Landragin A. ;
Bouyer P. ;
Gaffet S. ;
Pereira Dos Santos F. ;
Merlet S. .
Merlet, S. (Sebastien.Merlet@obspm.fr), 1600, Maik Nauka Publishing / Springer SBM (05) :266-274
[6]   Cooling of Sr to high phase-space density by laser and sympathetic cooling in isotopic mixtures [J].
Ferrari, G ;
Drullinger, RE ;
Poli, N ;
Sorrentino, F ;
Tino, GM .
PHYSICAL REVIEW A, 2006, 73 (02)
[7]   Mobile quantum gravity sensor with unprecedented stability [J].
Freier, C. ;
Hauth, M. ;
Schkolnik, V. ;
Leykauf, B. ;
Schilling, M. ;
Wziontek, H. ;
Scherneck, H-G ;
Mueller, J. ;
Peters, A. .
8TH SYMPOSIUM ON FREQUENCY STANDARDS AND METROLOGY 2015, 2016, 723
[8]   First gravity measurements using the mobile atom interferometer GAIN [J].
Hauth, M. ;
Freier, C. ;
Schkolnik, V. ;
Senger, A. ;
Schmidt, M. ;
Peters, A. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2013, 113 (01) :49-55
[9]   Active low frequency vertical vibration isolation [J].
Hensley, JM ;
Peters, A ;
Chu, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (06) :2735-2741
[10]   Demonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter [J].
Hu, Zhong-Kun ;
Sun, Bu-Liang ;
Duan, Xiao-Chun ;
Zhou, Min-Kang ;
Chen, Le-Le ;
Zhan, Su ;
Zhang, Qiao-Zhen ;
Luo, Jun .
PHYSICAL REVIEW A, 2013, 88 (04)