Intra- and inter-rater reliability of the rate of force development of hip abductor muscles measured by hand-held dynamometer

被引:14
作者
Takeda, Kazuya [1 ,2 ]
Tanabe, Shigeo [3 ]
Koyama, Soichiro [3 ]
Nagai, Tomoko [1 ]
Sakurai, Hiroaki [3 ]
Kanada, Yoshikiyo [3 ]
Shomoto, Koji [2 ]
机构
[1] Kawamura Hosp, Dept Rehabil, Gifu, Japan
[2] Kio Univ, Grad Sch Hlth Sci, Nara, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Rehabil, Toyoake, Aichi, Japan
关键词
Hand-held dynamometer; hip abductor muscles; rate of force development; reliability; FUNCTIONAL ELECTRICAL-STIMULATION; TOTAL KNEE ARTHROPLASTY; STRENGTH; GAIT; ASSOCIATION; PERFORMANCE; PEOPLE;
D O I
10.1080/1091367X.2017.1365078
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
The aim of this study was to clarify the intra- and inter-rater reliability of the rate of force development in hip abductor muscle force measurements using a hand-held dynamometer. Thirty healthy adults were separately assessed by two independent raters on two separate days. Rate of force development was calculated from the slope of the force-time curve that was divided into four time intervals (50, 100, 200, and 300 ms). The highest values of the three trials were used for statistical analysis. The intra-class correlation coefficient with a 95% confidence interval, standard error of measurement, and minimal detectable change at the 95% confidence level were calculated for each interval. For assessment of systematic error, Bland-Altman analysis was used. The results indicated that intra-and inter-rater reliability of the highest values at all intervals were sufficient (intra-class correlation coefficient >.7). The Bland-Altman analysis did not show systematic error in either reliability measure.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
[41]   Intra- and inter-rater reliability of the 10-meter ambulation test in hemiparesis is better barefoot at maximal speed [J].
Hutin, Emilie ;
Ghedira, Mouna ;
Loche, Catherine-Marie ;
Mardale, Valentina ;
Hennegrave, Catherine ;
Gracies, Jean-Michel ;
Bayle, Nicolas .
TOPICS IN STROKE REHABILITATION, 2018, 25 (05) :345-350
[42]   Development and reliability of a hand-held dynamometer device to measure the ankle dorsiflexor muscle strength [J].
Kimura, Masanobu ;
Ogata, Yuto ;
Akebi, Toru ;
Ochi, Mitsuhiro ;
Hachisuka, Kenji ;
Saeki, Satoru .
JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2018, 5
[43]   Inter- and Intratester Reliability of Strength Measurement of Knee Extension and Flexion with a Modified Hand-Held Dynamometer in Healthy Subjects [J].
Schaefer, A. ;
Dressel, M. ;
Kaemmerer, S. ;
Peschke, L. ;
Braun, M. Ramos ;
Schoettker-Koeniger, T. .
MANUELLE THERAPIE, 2015, 19 (01) :38-44
[44]   A Procedure for Measuring Anterior Scalene Morphology and Quality with Ultrasound Imaging: An Intra- and Inter-rater Reliability Study [J].
Valera-Calero, Juan Antonio ;
Gomez-Sanchez, Sonia ;
Fernandez-de-las-Penas, Cesar ;
Plaza-Manzano, Gustavo ;
Sanchez-Jorge, Sandra ;
Navarro-Santana, Marcos Jose .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (08) :1817-1823
[45]   Clinical evaluation of the anterior translation of glenohumeral joint using ultrasonography: an intra- and inter-rater reliability study [J].
Joseph, Leonard H. ;
Hussain, Rizuana I. ;
Pirunsan, Ubon ;
Naicker, Amaramalar S. ;
Htwe, Ohnmar ;
Paungmali, Aatit .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) :169-174
[46]   Intra- and inter-rater reliability of Fugl-Meyer Assessment of Lower Extremity early after stroke [J].
Hernandez, Edgar D. ;
Forero, Sandra M. ;
Galeano, Claudia P. ;
Barbosa, Nubia E. ;
Sunnerhagen, Katharina S. ;
Alt Murphy, Margit .
BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2021, 25 (06) :709-718
[47]   Intra- and inter-rater reliability of thoracic spine mobility and posture assessments in subjects with thoracic spine pain [J].
Jani Takatalo ;
Jari Ylinen ;
Tuomo Pienimäki ;
Arja Häkkinen .
BMC Musculoskeletal Disorders, 21
[48]   Intra- and inter-rater reliability and agreement of stimulus electrodiagnostic tests in post-COVID-19 patients [J].
Almeida, Isabella da Silva ;
Ferreira, Leandro Gomes de Jesus ;
Ventura, Alvaro de Almeida ;
Mansur, Henrique ;
Babault, Nicolas ;
Marqueti, Rita de Cassia ;
Durigan, Joao Luiz Quagliotti .
PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
[49]   Intra- and inter-rater reliability of thoracic spine mobility and posture assessments in subjects with thoracic spine pain [J].
Takatalo, Jani ;
Ylinen, Jari ;
Pienimaki, Tuomo ;
Hakkinen, Arja .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
[50]   The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain [J].
Juul, Tina ;
Langberg, Henning ;
Enoch, Flemming ;
Sogaard, Karen .
BMC MUSCULOSKELETAL DISORDERS, 2013, 14