Intra- and inter-rater reliability of the rate of force development of hip abductor muscles measured by hand-held dynamometer

被引:14
作者
Takeda, Kazuya [1 ,2 ]
Tanabe, Shigeo [3 ]
Koyama, Soichiro [3 ]
Nagai, Tomoko [1 ]
Sakurai, Hiroaki [3 ]
Kanada, Yoshikiyo [3 ]
Shomoto, Koji [2 ]
机构
[1] Kawamura Hosp, Dept Rehabil, Gifu, Japan
[2] Kio Univ, Grad Sch Hlth Sci, Nara, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Rehabil, Toyoake, Aichi, Japan
关键词
Hand-held dynamometer; hip abductor muscles; rate of force development; reliability; FUNCTIONAL ELECTRICAL-STIMULATION; TOTAL KNEE ARTHROPLASTY; STRENGTH; GAIT; ASSOCIATION; PERFORMANCE; PEOPLE;
D O I
10.1080/1091367X.2017.1365078
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
The aim of this study was to clarify the intra- and inter-rater reliability of the rate of force development in hip abductor muscle force measurements using a hand-held dynamometer. Thirty healthy adults were separately assessed by two independent raters on two separate days. Rate of force development was calculated from the slope of the force-time curve that was divided into four time intervals (50, 100, 200, and 300 ms). The highest values of the three trials were used for statistical analysis. The intra-class correlation coefficient with a 95% confidence interval, standard error of measurement, and minimal detectable change at the 95% confidence level were calculated for each interval. For assessment of systematic error, Bland-Altman analysis was used. The results indicated that intra-and inter-rater reliability of the highest values at all intervals were sufficient (intra-class correlation coefficient >.7). The Bland-Altman analysis did not show systematic error in either reliability measure.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [1] The intra- and inter-rater reliability of manual muscle testing and a hand-held dynamometer for measuring wrist strength in symptomatic and asymptomatic subjects
    Toemen, Angela
    Dalton, Sarah
    Sandford, Fiona
    HAND THERAPY, 2011, 16 (03) : 67 - 74
  • [2] Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner's Body and Comparison with Push Dynamometry
    Gonzalez-Rosalen, Javier
    Benitez-Martinez, Josep Carles
    Medina-Mirapeix, Francesc
    Cuerda-Del Pino, Alba
    Cervello, Antonio
    Martin-San Agustin, Rodrigo
    DIAGNOSTICS, 2021, 11 (07)
  • [3] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [4] Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography
    Macrae, Phoebe R.
    Doeltgen, Sebastian H.
    Jones, Richard D.
    Huckabee, Maggie-Lee
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 74 - 78
  • [5] The intra- and inter-rater reliabilities of lower extremity muscle strength assessment of healthy adults using a hand held dynamometer
    Kim, Seong-Gil
    Lee, Yun-Seob
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1799 - 1801
  • [6] Inter-rater and intra-rater reliability of belt-stabilized hand-held dynamometer using make test in lower extremity muscle strength assessment among healthy adults
    Espino, Reil Vinard S.
    Gonzalez-Suarez, Consuelo
    Ingram, Lewis A.
    Gomez, Ivan Neil B.
    Agarao, Kris Anthony T.
    Flores, Jazzmine Gale
    Bulseco, Nicole
    INTERNATIONAL JOURNAL OF OSTEOPATHIC MEDICINE, 2025, 56
  • [7] Intra- and inter-rater reliability of the Sollerman hand function test in patients with chronic stroke
    Brogardh, Christina
    Persson, Ann L.
    Sjolund, Bengt H.
    DISABILITY AND REHABILITATION, 2007, 29 (02) : 145 - 154
  • [8] Development, intra- and inter-rater reliability of the New Zealand Secretion Scale (NZSS)
    Miles, Anna
    Hunting, Alexandra
    INTERNATIONAL JOURNAL OF SPEECH-LANGUAGE PATHOLOGY, 2019, 21 (04) : 377 - 384
  • [9] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [10] Intra- and Inter-Rater Reliability of the Modified Tuck Jump Assessment
    Fort-Vanmeerhaeghe, Azahara
    Montalvo, Alicia M.
    Lloyd, Rhodri S.
    Read, Paul
    Myer, Gregory D.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2017, 16 (01) : 117 - 124