Four-dimensional patient-specific musculoskeletal model of the patient after Total Hip Arthroplasty

被引:4
作者
Otake, Y [1 ]
Suzuki, N [1 ]
Hattori, A [1 ]
Miki, H [1 ]
Yamamura, M [1 ]
Nakamura, N [1 ]
Sugano, N [1 ]
Yonenobu, K [1 ]
Ochi, T [1 ]
机构
[1] Jikei Univ, Sch Med, Inst High Dimens Med Imaging, Komae, Tokyo 2018601, Japan
来源
CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS | 2004年 / 1268卷
关键词
four-dimensional motion analysis; muscle model; total hip arthroplasty;
D O I
10.1016/j.ics.2004.03.207
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We constructed a four-dimensional (4D) patient-specific musculoskeletal model of the patient having had Total Hip Arthroplasty (THA). The model includes the three-dimensional skeletal structures, the muscles and the movement data from optical motion capture system. This model reflects the patient-specific characteristics of the bone geometry, implant alignment and the characteristics of the movement. The muscle model proposed in this paper is the string-typed model representing the route of the muscles. The strings expands and contracts according to the movement of the origin and insertion location of the muscle and we can estimate the direction of the muscle force and the length of the muscles. We developed models of the seven muscles and muscle groups related to the movement of the hip joint. By using this model, clinicians can predict the potential for dislocation or recognize the causes of dislocation, including the influence of the muscles. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 10 条
  • [1] The effect of femoral component head size on posterior dislocation of the artificial hip joint
    Bartz, RL
    Noble, PC
    Kadakia, NR
    Tullos, HS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) : 1300 - 1307
  • [2] Application of spherical and cylindrical wrapping algorithms in a musculoskeletal model of the upper limb
    Charlton, IW
    Johnson, GR
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (09) : 1209 - 1216
  • [3] The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios
    D'Lima, DD
    Urquhart, AG
    Buehler, KO
    Walker, RH
    Colwell, CW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) : 315 - 321
  • [4] AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES
    DELP, SL
    LOAN, JP
    HOY, MG
    ZAJAC, FE
    TOPP, EL
    ROSEN, JM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) : 757 - 767
  • [5] Gottschalk S., 1996, Computer Graphics Proceedings. SIGGRAPH '96, P171, DOI 10.1145/237170.237244
  • [6] Hagio K, 2002, CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, P1059
  • [7] Otake Y, 2002, LECT NOTES COMPUT SC, V2488, P241
  • [8] OTAKE Y, 2003, MMVR, V11, P251
  • [9] Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation
    Seki, M
    Yuasa, N
    Ohkuni, K
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (04) : 513 - 517
  • [10] ZAJAC FE, 1989, CRIT REV BIOMED ENG, V17, P359