Application of hybrid external fixation by the "joystick method" in bicondylar tibial plateau fractures: Technical note

被引:5
作者
Kuyucu, Ersin [1 ]
Kara, Adnan [1 ]
Say, Ferhat [2 ]
Erdil, Mehmet [1 ]
Bulbul, Murat [1 ]
Gulenc, Baris [1 ]
机构
[1] Istanbul Medipol Univ, Dept Orthoped & Traumatol, Fac Med, Istanbul, Turkey
[2] Ondokuz Mayis Univ, Dept Orthoped & Traumatol, Fac Med, Samsun, Turkey
来源
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY | 2018年 / 24卷 / 03期
关键词
Fracture complication; hybrid external fixation; tibial plateau fracture;
D O I
10.5505/tjtes.2017.27848
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: This study aimed to present clinical outcomes in patients with tibial plateau fractures who were treated with hybrid external fixators and describe the details of our technique. Schanz screws were synchronously applied and used as a joystick for fracture reduction. METHODS: The study population included 72 patients with bicondylar tibial plateau fractures classified as type 41 -C2 according to the AO classification. Joint reduction was maintained using Schanz screws transmitted through tibial condyles as a joystick under fluoroscopy. The patients then underwent surgery with these Schanz screws and a hybrid external fixation system. RESULTS: The median age of the patients was 39 (21-67) years, and the median follow-up time was 21 (12-35) months. The mean knee flexion and extension were 105 degrees (80 degrees-125 degrees) and 0 degrees (-5 degrees-7 degrees), respectively. The mean varus laxity and valgus laxity were 4.30 degrees (2 degrees-7 degrees) and 3.10 degrees (2 degrees-5 degrees), respectively. Four patients had leg shortness of 0.4-1.1 cm. The external fixators were removed between 8 and 16 weeks (mean = 11 weeks) postoperatively. The KSS scores at the end of I year were "excellent" for 48 patients. "good" for 19 patients, and "inadequate" for 5 patients. CONCLUSION: With the synchronous application of the two Schanz screws of 6.5-mm thickness and the two-drill technique under fluoroscopic guidance, we obtained stable reductions over a short period. No patient experienced major complications, and this enabled early weight bearing and a return to daily living activities.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 22 条
[1]   The outcome following fixation of bicondylar tibial plateau fractures [J].
Ahearn, N. ;
Oppy, A. ;
Halliday, R. ;
Rowett-Harris, J. ;
Morris, S. A. ;
Chesser, T. J. ;
Livingstone, J. A. .
BONE & JOINT JOURNAL, 2014, 96B (07) :956-962
[2]  
APLEY AG, 1979, ORTHOP CLIN N AM, V10, P61
[3]  
Ballard Brooke L, 2012, J Bone Joint Surg Am, V94, pe64, DOI 10.2106/JBJS.K.00046
[4]  
Boogaerts J G, 1999, Acta Anaesthesiol Belg, V50, P95
[5]   Retrospective review of tibial plateau fractures treated by two methods without staging [J].
Conserva, Vito ;
Vicenti, Giovanni ;
Allegretti, Giovanni ;
Filipponi, Marco ;
Monno, Alessandra ;
Picca, Girolamo ;
Moretti, Biagio .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (10) :1951-1956
[6]  
DECOSTER TA, 1988, CLIN ORTHOP RELAT R, P196
[7]   Surgical treatment of complex tibial plateau fractures by closed reduction and external fixation. A review of 32 consecutive cases operated [J].
Faldini, C. ;
Manca, M. ;
Pagkrati, S. ;
Leonetti, D. ;
Nanni, M. ;
Grandi, G. ;
Romagnoli, M. ;
Himmelmann, M. .
JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2005, 6 (04) :188-193
[8]   CLASSIFICATION OF FRACTURES OF THE TIBIAL CONDYLES [J].
HONKONEN, SE ;
JARVINEN, MJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06) :840-847
[9]  
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[10]  
Isiklar ZU, 1999, DIZ CERRAHISI, P399