Three-dimensional distributions of elements in biological samples by energy-filtered electron tomography

被引:54
作者
Leapman, RD [1 ]
Kocsis, E [1 ]
Zhang, G [1 ]
Talbot, TL [1 ]
Laquerriere, P [1 ]
机构
[1] NIH, ORS, Div Bioengn & Phys Sci, Bethesda, MD 20892 USA
关键词
electron tomography; energy-filtered imaging; core excitation; phosphorus distributions; ribosomes; three-dimensional reconstruction; hyperbaric freezing;
D O I
10.1016/j.ultramic.2004.03.002
中图分类号
TH742 [显微镜];
学科分类号
摘要
By combining electron tomography with energy-filtered electron microscopy, we have shown the feasibility of determining the three-dimensional distributions of phosphorus in biological specimens. Thin sections of the nematode, Caenorhabditis elegans were prepared by high-pressure freezing,. freeze-substitution and plastic embedding. Images were recorded at energy losses above and below the phosphorus L-2,L-3 edge using a post-column imaging filter operating at a beam energy of 120 keV. The unstained specimens exhibited minimal contrast in bright-field images. After it was determined that the specimen was sufficiently thin to allow two-window ratio imaging of phosphorus, pairs of pre-edge and post-edge images were acquired in series over a tilt range of +/-55degrees at 5degrees increments for two orthogonal tilt axes. The projected phosphorus distributions were aligned using the pre-edge images that contained inelastic contrast from colloidal gold particles deposited on the specimen surface. A reconstruction and surface rendering of the phosphorus distribution clearly revealed features 15-20 nm in diameter, which were identified as ribosomes distributed along the stacked membranes of endoplasmic reticulum and in the cytoplasm. The sensitivity of the technique was estimated at <35 phosphorus atoms per voxel based on the known total ribosomal phosphorus content of approximately 7000 atoms. Although a high electron dose of approximately 10(7) e/nm(2) was required to record two-axis tilt series, specimens were sufficiently stable to allow image alignment and tomographic reconstruction. Published by Elsevier B.V.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 42 条
[1]  
Altun Z.F., 2002, WORMATLAS
[2]   Stoichiometric analysis of protein- and nucleic acid-based structures in the cell nucleus [J].
Bazett-Jones, DP ;
Hendzel, MJ ;
Kruhlak, MJ .
MICRON, 1999, 30 (02) :151-157
[3]   SHORT-RANGE DNA LOOPING BY THE XENOPUS HMG-BOX TRANSCRIPTION FACTOR, XUBF [J].
BAZETTJONES, DP ;
LEBLANC, B ;
HERFORT, M ;
MOSS, T .
SCIENCE, 1994, 264 (5162) :1134-1137
[4]  
BRENNER S, 1974, GENETICS, V77, P71
[5]   TOWARDS AUTOMATIC ELECTRON TOMOGRAPHY [J].
DIERKSEN, K ;
TYPKE, D ;
HEGERL, R ;
KOSTER, AJ ;
BAUMEISTER, W .
ULTRAMICROSCOPY, 1992, 40 (01) :71-87
[6]  
Egerton RF., 2011, ELECT ENERGY LOSS SP
[7]   Three-dimensional imaging of biological complexity [J].
Frank, J ;
Wagenknecht, T ;
McEwen, BF ;
Marko, M ;
Hsieh, CE ;
Mannella, CA .
JOURNAL OF STRUCTURAL BIOLOGY, 2002, 138 (1-2) :85-91
[8]  
Frank J., 1992, ELECT TOMOGRAPHY
[9]   Energy filtered electron tomography of ice-embedded actin and vesicles [J].
Grimm, R ;
Barmann, M ;
Hackl, W ;
Typke, D ;
Sackmann, E ;
Baumeister, W .
BIOPHYSICAL JOURNAL, 1997, 72 (01) :482-489
[10]   Three-dimensional structure of herpes simplex virus from cryo-electron tomography [J].
Grünewald, K ;
Desai, P ;
Winkler, DC ;
Heymann, JB ;
Belnap, DM ;
Baumeister, W ;
Steven, AC .
SCIENCE, 2003, 302 (5649) :1396-1398