Corneal Curvature: the Influence of Corneal Accommodation and Biomechanics on Corneal Shape

被引:11
作者
Wallace, Henry B. [1 ]
McKelvie, James [1 ]
Green, Colin R. [1 ]
Misra, Stuti L. [1 ]
机构
[1] Univ Auckland, New Zealand Natl Eye Ctr, Fac Med & Hlth Sci, Dept Ophthalmol, Auckland, New Zealand
关键词
biomechanics; ocular accommodation; cornea; optics; HUMAN CILIARY MUSCLE; AGE-RELATED-CHANGES; LENS; ANTERIOR;
D O I
10.1167/tvst.8.4.5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Variation in the presence and magnitude of corneal conformational changes during accommodation may predict postoperative ectasia following refractive surgery and assist in the early diagnosis of corneal ectatic disorders. The current study aimed to establish a baseline for corneal refractive changes during ocular accommodation and to clarify the role of biomechanical factors in predicting these changes in a population without corneal pathology. Methods: GALILEI G2 corneal tomography was assessed in 63 participants in both the accommodated and unaccommodated states. Four diopters (D) of physiological accommodation were induced using near-acuity calibrated words viewed through an externally mounted beam splitter mounted on a three-dimensional-printed frame. Corneal biomechanical characteristics were assessed with the CorVis-ST instrument, and statistical analysis was completed in R software. Results: Anterior chamber depth was reduced by 0.10 +/- 0.07 mm with accommodation (P < 0.01). Areas of statistically significant change in corneal curvatures were seen in all participants with accommodation. Mean anterior instantaneous corneal power increased in the superior-nasal periphery (0.1 D, 95% confidence interval [CI] = 0.05-0.2 D) and decreased in the inferior-temporal periphery (0.1 D, 95% CI = -0.05 to -0.15 D). Corneal stiffness and the corneal deformation amplitude ratio predicted peripheral corneal curvature changes with accommodation (P < 0.05). Conclusion: Corneal conformational changes occur during accommodation in normal subjects. Further studies are required to assess the magnitude of corneal changes during accommodation in patients with corneal ectasia. Translational Relevance: An externally mounted beam splitter can be used to modify the visual target presented by clinical ocular imaging instruments. Corneal conformational changes during accommodation may be useful in the diagnosis of corneal ectasia.
引用
收藏
页数:14
相关论文
共 36 条
[1]   An indentation technique to characterize the mechanical and viscoelastic properties of human and porcine corneas [J].
Ahearne, Mark ;
Yang, Ying ;
Then, Kong Y. ;
Liu, Kuo-Kang .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (09) :1608-1616
[2]   METHOD OF BIVARIATE INTERPOLATION AND SMOOTH SURFACE FITTING BASED ON LOCAL PROCEDURES [J].
AKIMA, H .
COMMUNICATIONS OF THE ACM, 1974, 17 (01) :18-20
[3]   Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer [J].
Altiparmak, Zeynep ;
Yagci, Ramazan ;
Guler, Emre ;
Arslanyilmaz, Zeynel ;
Canbal, Metin ;
Hepsen, Ibrahim F. .
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2015, 45 (06) :243-248
[4]   BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[5]  
Atchison D, 2000, OPTICS HUMAN EYE, P64
[6]   Effect of Accommodation on Corneal Topography [J].
Bayramlar, Huseyin ;
Sadigov, Fariz ;
Yildirim, Aydin .
CORNEA, 2013, 32 (09) :1251-1254
[7]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[8]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]   Corneal topography and accommodation [J].
Buehren, T ;
Collins, MJ ;
Loughridge, J ;
Carney, LG ;
Iskander, DR .
CORNEA, 2003, 22 (04) :311-316