A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts

被引:111
作者
Desai, Nimesh D. [1 ]
Miwa, Senri [1 ]
Kodama, David [1 ]
Koyama, Taadaki [1 ]
Cohen, Gideon [1 ]
Pelletier, Marc P. [1 ]
Cohen, Eric A. [1 ]
Christakis, George T. [1 ]
Goldman, Bernard S. [1 ]
Fremes, Stephen E. [1 ]
机构
[1] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Toronto, ON, Canada
基金
加拿大创新基金会;
关键词
D O I
10.1016/j.jtcvs.2005.09.061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Early coronary bypass graft failures may be preventable if identified intraoperatively. The purpose of this investigation was to compare the diagnostic accuracy of two intraoperative graft assessment techniques, transit-time ultrasound flow measurement and indocyanine green fluorescent-dye graft angiography. Methods: Patents undergoing isolated coronary artery bypass grafting with no contraindications for postoperative angiography were enrolled in the study. Patients were randomly assigned to be evaluated with either indocyanine green angiography (Novadaq Spy angiography system; Novadaq Technologies Inc, Concord, Ontario, Canada) and then transit-time ultrasonic flow measurement (Medtronic Medi-Stim Butterfly Flowmeter TTF measurement system; Medtronic Inc, Minneapolis, Minn) or transit-time flow then indocyanine green angiography. Patients underwent x-ray angiography on postoperative day 4. The primary end point of the trial was to determine the sensitivity and specificity of the two techniques versus reference standard x-ray angiography to detect graft occlusion or greater than 50% stenosis in the graft or perianastomotic area. Results: Between February 2004 and March 2005, 106 patients were enrolled and x-ray angiography was performed in 46 patients. In total, 139 grafts were reviewed with all three techniques and 12 grafts (8.2%) were demonstrated to have greater than 50% stenosis or occlusion by the reference standard. The sensitivity and specificity of indocyanine green angiography to detect greater than 50% stenosis or occlusion was 83.3% and 100%, respectively. The sensitivity and specificity of transit-time ultrasonic flow measurement to detect greater than 50% stenosis or occlusion was 25% and 98.4%, respectively. The P value for the overall comparison of sensitivity and specificity between indocyanine green angiography and transit-time flow ultrasonography was .011. The difference between sensitivity for indocyanine green angiography and transit-time flow measurement was 58% with a 95% confidence interval of 30% to 86%, P = .023. Conclusion: Indocyanine green angiography provides better diagnostic accuracy for detecting clinically significant graft errors than does transit-time ultrasound flow measurement.
引用
收藏
页码:585 / 594
页数:10
相关论文
共 24 条
  • [1] Analyses of coronary graft patency after aprotinin use: Results from the international multicenter aprotinin graft patency experience (IMAGE) trial
    Alderman, EL
    Levy, JH
    Rich, JB
    Nili, M
    Vidne, B
    Schaff, H
    Uretzky, G
    Pettersson, G
    Thiis, JJ
    Hantler, CB
    Chaitman, B
    Nadel, A
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05) : 716 - 729
  • [2] Aggressive cholesterol lowering delays saphenous vein graft atherosclerosis in women, the elderly, and patients with associated risk factors - NHLBI post coronary artery bypass graft clinical trial
    Campeau, L
    Hunninghake, DB
    Knatterud, GL
    White, CW
    Domanski, M
    Forman, SA
    Forrester, JS
    Geller, NL
    Gobel, FL
    Herd, JA
    Hoogwerf, BJ
    Rosenberg, Y
    [J]. CIRCULATION, 1999, 99 (25) : 3241 - 3247
  • [3] Canver CC, 1997, J CARDIOVASC SURG, V38, P211
  • [4] A PLATELET-INHIBITOR-DRUG TRIAL IN CORONARY-ARTERY BYPASS OPERATIONS - BENEFIT OF PERIOPERATIVE DIPYRIDAMOLE AND ASPIRIN THERAPY ON EARLY POSTOPERATIVE VEIN-GRAFT PATENCY
    CHESEBRO, JH
    CLEMENTS, IP
    FUSTER, V
    ELVEBACK, LR
    SMITH, HC
    BARDSLEY, WT
    FRYE, RL
    HOLMES, DR
    VLIETSTRA, RE
    PLUTH, JR
    WALLACE, RB
    PUGA, FJ
    ORSZULAK, TA
    PIEHLER, JM
    SCHAFF, HV
    DANIELSON, GK
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (02) : 73 - 78
  • [5] Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting
    D'Ancona, G
    Karamanoukian, HL
    Ricci, M
    Schmid, S
    Bergsland, J
    Salerno, TA
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) : 287 - 293
  • [6] DANCONA G, 2001, INTRAOPERATIVE GRAFT, P105
  • [7] Desai N, 2005, J AM COLL CARDIOL, V45, p78A
  • [8] DESAI ND, 2004, NEW ENGL J MED
  • [9] METHODS FOR COMPARING EVENT RATES IN INTERVENTION STUDIES WHEN THE UNIT OF ALLOCATION IS A CLUSTER
    DONNER, A
    KLAR, N
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1994, 140 (03) : 279 - 289
  • [10] Intraoperative MIDCABG arteriography via the left radial artery: A comparison with Doppler ultrasound for assessment of graft patency
    Elbeery, JR
    Brown, PM
    Chitwood, WR
    [J]. ANNALS OF THORACIC SURGERY, 1998, 66 (01) : 51 - 55