Biomechanical Analysis of All-Suture Suture Anchor Fixation Compared With Conventional Suture Anchors and Interference Screws for Biceps Tenodesis

被引:28
作者
Frank, Rachel M. [1 ]
Bernardoni, Eamon D. [1 ]
Veera, Shreya S. [1 ]
Waterman, Brian R. [1 ]
Griffin, Justin W. [1 ]
Shewman, Elizabeth F. [1 ]
Cole, Brian J. [1 ]
Romeo, Anthony A. [1 ]
Verma, Nikhil N. [1 ]
机构
[1] Rush Univ, Sect Sports Med, Dept Orthopaed Surg, Med Ctr, Chicago, IL 60612 USA
基金
美国国家卫生研究院;
关键词
LONG HEAD; TENDON; STRENGTH; REPAIR; LENGTH;
D O I
10.1016/j.arthro.2019.01.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the biomechanical properties of all-suture suture anchors (ASSAs) with conventional interference screws (CISs) and conventional suture anchors (CSAs) for long head of the biceps tendon fixation during proximal biceps tenodesis (BT). Methods: We randomized 21 fresh-frozen human cadaveric shoulders into 3 subpectoral BT treatment groups: ASSA, CSA, and CIS. Each construct was cyclically loaded from 5 to 70 N for 500 cycles (1 Hz). All specimens that survived cyclic loading were then pulled to failure (1 mm/s). Elongation, maximum load, energy, and failure mode were recorded. The humerus was stripped of tissue and then subjected to torsional displacement at a rate of 1 degrees/s until fracture occurred. Maximum load, displacement, stiffness, and energy were recorded. Results: During tendon testing, 3 specimens (43%) in the CIS group failed early during cyclic testing by the tendon tearing at the screw-tendon interface. All other specimens in the CIS group, as well as all specimens in the ASSA and CSA groups, survived cyclic testing and failed during pull-to-failure testing. Failure occurred at the tendon-anchor or -screw interface in all specimens (100%), with no anchor or screw pullout. The CIS group had significantly decreased elongation (8.9 +/- 2.23 mm) at maximum load compared with the ASSA (19.2 +/- 5.2 mm) and CSA (18.9 +/- 2.23 mm) groups (P = .001). During torsional testing, the ASSA group was able to withstand significantly greater torsional displacement (9.22 degrees +/- 0.86 degrees) before failure and had greater energy to failure (497.3 +/- 45 Nmm-degrees) than the CIS group (6.13 degrees +/- 1.24 degrees and 256.6 +/- 70.3 Nmm-degrees, respectively; P = .005). Conclusions: This study shows that the biomechanical properties of ASSA, CSA, and CIS constructs are similar. The interference screw group had lower tendon elongation at maximum load but had several early failures compared with the suture anchor groups. The use of suture anchors results in maximum tendon and torsional bone loads similar to interference screws for the long head of the biceps tendon. Torsional testing of the CIS resulted in spiral fractures traversing the screw tunnel in 100% of the specimens, which was not found in the suture anchor groups.
引用
收藏
页码:1760 / 1768
页数:9
相关论文
共 28 条
  • [1] Biceps tenodesis for long head of the biceps after auto-rupture or failed surgical tenotomy: results in an active population
    Anthony, Shawn G.
    McCormick, Frank
    Gross, Daniel J.
    Golijanin, Petar
    Provencher, Matthew T.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (02) : E36 - E40
  • [2] Torsional Fracture of the Humerus after Subpectoral Biceps Tenodesis with an Interference Screw: A Biomechanical Cadaveric Study
    Beason, David P.
    Shah, Jay P.
    Duckett, James W.
    Jost, Patrick W.
    Fleisig, Glenn S.
    Cain, E. Lyle, Jr.
    [J]. CLINICAL BIOMECHANICS, 2015, 30 (09) : 915 - 920
  • [3] Biomechanical Comparison of All-Suture Anchor Fixation and Interference Screw Technique for Subpectoral Biceps Tenodesis
    Chiang, Florence L.
    Hong, Chih-Kai
    Chang, Chih-Hsun
    Lin, Cheng-Li
    Jou, I-Ming
    Su, Wei-Ren
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (07) : 1247 - 1252
  • [4] Maximum load to failure and tensile displacement of an all-suture glenoid anchor compared with a screw-in glenoid anchor
    Dwyer, Tim
    Willett, Thomas L.
    Dold, Andrew P.
    Petrera, Massimo
    Wasserstein, David
    Whelan, Danny B.
    Theodoropoulos, John S.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (02) : 357 - 364
  • [5] Interference Screw Versus Suture Anchor Fixation for Subpectoral Tenodesis of the Proximal Biceps Tendon: A Cadaveric Study
    Golish, S. Raymond
    Caldwell, Paul E.
    Miller, Mark D.
    Singanamala, Naveen
    Ranawat, Anil S.
    Treme, Gehron
    Pearson, Sara E.
    Costic, Ryan
    Sekiya, Jon K.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (10) : 1103 - 1108
  • [6] Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model
    Goschka, Andrew M.
    Hafer, Jason S.
    Reynolds, Kirk A.
    Aberle, Nicholas S., II
    Baldini, Todd H.
    Hawkins, Monica J.
    McCarty, Eric C.
    [J]. CLINICAL BIOMECHANICS, 2015, 30 (08) : 808 - 813
  • [7] Green SM, 2009, AM J ORTHOP, V38, P170
  • [8] The influence of tendon length and fit on the strength of a tendon-bone tunnel complex - A biomechanical and histologic study in the dog
    Greis, PE
    Burks, RT
    Bachus, K
    Luker, MG
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (04) : 493 - 497
  • [9] Long Head Biceps Tenodesis With a Knotless Cinch Suture Anchor: A Biomechanical Analysis
    Kaback, Lee A.
    Gowda, Ashok L.
    Paller, David
    Green, Andrew
    Blaine, Theodore
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (05) : 831 - 835
  • [10] Open Subpectoral Biceps Tenodesis: Reliable Treatment for All Biceps Tendon Pathology
    Kane, Patrick
    Hsaio, Philip
    Tucker, Bradford
    Freedman, Kevin B.
    [J]. ORTHOPEDICS, 2015, 38 (01) : 37 - 41