An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects

被引:144
作者
Wong, Mico Yee-Man [1 ]
Poon, Carmen Chung-Yan [1 ]
Zhang, Yuan-Ting [1 ,2 ,3 ]
机构
[1] Chinese Univ Hong Kong, Joint Res Ctr Biomed Engn, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
[2] Chinese Acad Sci, SIAT Inst Biomed & Hlth Engn, Shenzhen, Peoples R China
[3] Chinese Acad Sci, Key Lab Biomed Informat & Hlth Engn, Shenzhen, Peoples R China
关键词
Cuffless; Blood pressure; Pulse transit time; Repeatability test; SENSOR CONTACT FORCE; WAVE VELOCITY; SLEEP; AORTA;
D O I
10.1007/s10558-009-9070-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the present study, we investigated the relationship between blood pressure (BP) and pulse transit time (PTT) and evaluated the accuracy of the PTT-based cuffless BP estimation on 14 normotensive subjects. Least-squares regression was used to estimate BP in the first test and a repeatability test carried out half year later. BP in the repeatability test was also estimated using the regression coefficients in the first test. The results illustrated that in the first and repeatability tests (1) arterial BP increased and PTT decreased acutely after the exercises and (2) systolic BP was highly correlated with PTT. In the repeatability test, the estimation differences from the references were 0.0 +/- 5.3 mmHg and 0.0 +/- 2.9 mmHg for systolic and diastolic BPs respectively using least-squares regression. However, the estimation differences increased to 1.4 +/- A 10.2 mmHg and 2.1 +/- A 7.3 mmHg for systolic and diastolic BPs, respectively when the regression coefficients in the first test were used for prediction. In summary, reasonable BP estimations were given in the first and repeatability tests but not using the regression coefficients obtained 6 months ago for some subjects.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 29 条
[1]   THE COVARIATION OF BLOOD-PRESSURE AND PULSE TRANSIT-TIME IN HYPERTENSIVE PATIENTS [J].
ALLEN, RA ;
SCHNEIDER, JA ;
DAVIDSON, DM ;
WINCHESTER, MA ;
TAYLOR, CB .
PSYCHOPHYSIOLOGY, 1981, 18 (03) :301-306
[2]  
BROCK J, 1993, J AMBUL MONIT, V6, P195
[3]  
Ezzati M., 2004, COMP QUANTIFICATION, P883
[4]   Pulse transit time in paediatric respiratory sleep studies [J].
Foo, Jong Yong A. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (01) :17-25
[5]   PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, MH ;
BABBS, CF ;
BOURLAND, JD ;
TACKER, WA .
PSYCHOPHYSIOLOGY, 1981, 18 (01) :71-74
[6]   MEASUREMENTS OF YOUNGS MODULUS OF ELASTICITY OF THE CANINE AORTA WITH ULTRASOUND [J].
HUGHES, DJ ;
BABBS, CF ;
GEDDES, LA ;
BOURLAND, JD .
ULTRASONIC IMAGING, 1979, 1 (04) :356-367
[7]  
Kearney PM, 2005, LANCET, V365, P217, DOI 10.1016/S0140-6736(05)70151-3
[8]   PULSE TRANSIT-TIME AND BLOOD-PRESSURE - AN INTENSIVE ANALYSIS [J].
LANE, JD ;
GREENSTADT, L ;
SHAPIRO, D ;
RUBINSTEIN, E .
PSYCHOPHYSIOLOGY, 1983, 20 (01) :45-49
[9]   Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients [J].
Laurent, S ;
Boutouyrie, P ;
Asmar, R ;
Gautier, I ;
Laloux, B ;
Guize, L ;
Ducimetiere, P ;
Benetos, A .
HYPERTENSION, 2001, 37 (05) :1236-1241
[10]  
Muehlsteff J, 2006, P 28 ANN C IEEE EMBC