The tidal volume challenge improves the reliability of dynamic preload indices during robot-assisted laparoscopic surgery in the Trendelenburg position with lung-protective ventilation

被引:13
作者
Jun, Joo-Hyun [1 ]
Chung, Rack Kyung [2 ]
Baik, Hee Jung [2 ]
Chung, Mi Hwa [1 ]
Hyeon, Joon-Sang [1 ]
Lee, Young-Goo [3 ]
Park, Sung-Ho [4 ]
机构
[1] Hallym Univ, Kangnam Sacred Heart Hosp, Dept Anesthesiol & Pain Med, Coll Med, Seoul, South Korea
[2] Ewha Womans Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul 1071, South Korea
[3] Hallym Univ, Kangnam Sacred Heart Hosp, Dept Urol, Coll Med, Seoul, South Korea
[4] Hallym Univ, Kangnam Sacred Heart Hosp, Dept Obstet & Gynecol, Coll Med, Seoul, South Korea
关键词
Pulse pressure variation; Stroke volume variation; Fluid responsiveness; Tidal volume challenge; Pneumoperitoneum; Trendelenburg position; PULSE PRESSURE VARIATION; PREDICT FLUID RESPONSIVENESS; POSTOPERATIVE PULMONARY COMPLICATIONS; ARTERIAL WAVE-FORM; MECHANICAL VENTILATION; RENAL PERFUSION; CARDIAC-OUTPUT; PNEUMOPERITONEUM; ANESTHESIA; METAANALYSIS;
D O I
10.1186/s12871-019-0807-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background The reliability of pulse pressure variation (PPV) and stroke volume variation (SVV) is controversial under pneumoperitoneum. In addition, the usefulness of these indices is being called into question with the increasing adoption of lung-protective ventilation using low tidal volume (V-T) in surgical patients. A recent study indicated that changes in PPV or SVV obtained by transiently increasing V-T (V-T challenge) accurately predicted fluid responsiveness even in critically ill patients receiving low V-T. We evaluated whether the changes in PPV and SVV induced by a V-T challenge predicted fluid responsiveness during pneumoperitoneum. Methods We performed an interventional prospective study in patients undergoing robot-assisted laparoscopic surgery in the Trendelenburg position under lung-protective ventilation. PPV, SVV, and the stroke volume index (SVI) were measured at a V-T of 6 mL/kg and 3 min after increasing the V-T to 8 mL/kg. The V-T was reduced to 6 mL/kg, and measurements were performed before and 5 min after volume expansion (infusing 6% hydroxyethyl starch 6 ml/kg over 10 min). Fluid responsiveness was defined as >= 15% increase in the SVI. Results Twenty-four of the 38 patients enrolled in the study were responders. In the receiver operating characteristic curve analysis, an increase in PPV > 1% after the V-T challenge showed excellent predictive capability for fluid responsiveness, with an area under the curve (AUC) of 0.95 [95% confidence interval (CI), 0.83-0.99, P < 0.0001; sensitivity 92%, specificity 86%]. An increase in SVV > 2% after the V-T challenge predicted fluid responsiveness, but showed only fair predictive capability, with an AUC of 0.76 (95% CI, 0.60-0.89, P < 0.0006; sensitivity 46%, specificity 100%). The augmented values of PPV and SVV following V-T challenge also showed the improved predictability of fluid responsiveness compared to PPV and SVV values (as measured by V-T) of 6 ml/kg. Conclusions The change in PPV following the V-T challenge has excellent reliability in predicting fluid responsiveness in our surgical population. The change in SVV and augmented values of PPV and SVV following this test are also reliable.
引用
收藏
页数:11
相关论文
共 48 条
  • [1] Elucidating the relationship between cardiac preload and renal perfusion under pneumoperitoneum
    Bergman, Simon
    Nutting, Arni
    Feldman, Liane S.
    Vassiliou, Melina C.
    Andrew, Christopher G.
    Demyttenaere, Sebastian
    Woo, Debbie
    Carli, Franco
    Jutras, Luc
    Buthieu, Jean
    Stanbridge, Donna D.
    Fried, Gerald M.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (05): : 794 - 800
  • [2] Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum
    Bliacheriene, F.
    Machado, S. B.
    Fonseca, E. B.
    Otsuke, D.
    Auler, J. O. C., Jr.
    Michard, F.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (09) : 1268 - 1272
  • [3] Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach
    Cannesson, Maxime
    Le Manach, Yannick
    Hofer, Christoph K.
    Goarin, Jean Pierre
    Lehot, Jean-Jacques
    Vallet, Benoit
    Tavernier, Benoit
    [J]. ANESTHESIOLOGY, 2011, 115 (02) : 231 - 241
  • [4] What is a fluid challenge?
    Cecconi, Maurizio
    Parsons, Anthony K.
    Rhodes, Andrew
    [J]. CURRENT OPINION IN CRITICAL CARE, 2011, 17 (03) : 290 - 295
  • [5] Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome
    Chiumello, Davide
    Carlesso, Eleonora
    Cadringher, Paolo
    Caironi, Pietro
    Valenza, Franco
    Polli, Federico
    Tallarini, Feclerica
    Cozzi, Paola
    Cressoni, Massimo
    Colombo, Angelo
    Marini, John J.
    Gattinoni, Luciano
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 178 (04) : 346 - 355
  • [6] Effects of Recruitment Maneuver and Positive End-expiratory Pressure on Respiratory Mechanics and Transpulmonary Pressure during Laparoscopic Surgery
    Cinnella, Gilda
    Grasso, Salvatore
    Spadaro, Savino
    Rauseo, Michela
    Mirabella, Lucia
    Salatto, Potito
    De Capraris, Antonella
    Nappi, Luigi
    Greco, Pantaleo
    Dambrosio, Michele
    [J]. ANESTHESIOLOGY, 2013, 118 (01) : 114 - 122
  • [7] Increasing mean arterial blood pressure in sepsis: effects on fluid balance, vasopressor load and renal function
    Correa, Thiago Domingos
    Vuda, Madhusudanarao
    Takala, Jukka
    Djafarzadeh, Siamak
    Silva, Eliezer
    Jakob, Stephan Mathias
    [J]. CRITICAL CARE, 2013, 17 (01)
  • [8] Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
    De Backer, D
    Heenen, S
    Piagnerelli, M
    Koch, M
    Vincent, JL
    [J]. INTENSIVE CARE MEDICINE, 2005, 31 (04) : 517 - 523
  • [9] Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery
    Deflandre, E.
    Bonhomme, V.
    Hans, P.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (02) : 245 - 250
  • [10] Targeting individual hemodynamics to maintain renal perfusion during pneumoperitoneum in a porcine model
    Demyttenaere, Sebastian V.
    Taqi, Ali
    Polyhronopoulos, Gerry N.
    Bergman, Simon
    Stanbridge, Donna D.
    Unikowsky, Bernard
    Carli, Franco
    Fried, Gerald M.
    Feldman, Liane S.
    [J]. SURGERY, 2007, 142 (03) : 350 - 356