Monitoring of endocrine disruptors by capillary electrophoresis amperometric detector

被引:16
作者
Ha, Kon [2 ]
Joo, Gi-sung [2 ]
Jha, Sandeep Kumar [2 ]
Kim, Yong-Sang [1 ,2 ]
机构
[1] Myongji Univ, Dept Elect Engn, Yongin 449728, Gyeonggi, South Korea
[2] Myongji Univ, Dept Nano Sci Engn, Yongin 449728, Gyeonggi, South Korea
关键词
Capillary electrophoresis; Styrofoam; Endocrine disruptor; Bisphenol A (BPA); Amperometry; Prussian blue (PB); BISPHENOL-A; IN-VITRO; BIOSENSOR;
D O I
10.1016/j.mee.2009.02.025
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A capillary electrophoresis amperometric detector was fabricated using Prussian blue (PB) modified indium tin oxide (ITO) electrode and twisted microchannel configuration. These devices were used for detection of endocrine disruptors, such as bisphenol A (BPA) and butylphenol after their effective separation in microchannel. The microchip had a limit of detection (LOD) as low as 59 nM for analytes. This approach was further applied in detection of these contaminants in Styrofoam food container used in many East Asian countries, such as Korea and China, for packaging of instant noodle, a popular fast food. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1407 / 1410
页数:4
相关论文
共 50 条
[31]   Amperometric biosensor coupled to capillary electrophoresis for glucose determination [J].
Chen, G ;
Wang, YT ;
Yang, PY .
MICROCHIMICA ACTA, 2005, 150 (3-4) :239-245
[32]   Separation and determination of cyclodextrins by capillary electrophoresis with amperometric detection [J].
Fang, YZ ;
Gong, FY ;
Fang, XM ;
Fu, CG .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :39-45
[33]   Microchip capillary electrophoresis with amperometric detection for several carbohydrates [J].
Lee, HL ;
Chen, SC .
TALANTA, 2004, 64 (01) :210-216
[34]   Determination of sugars in tobacco by capillary electrophoresis with amperometric detection [J].
Liu, SM ;
Song, LN ;
Zhang, TS ;
Fang, YZ .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (10) :1233-1236
[35]   An amperometric detector with a tubular electrode deposited on the capillary for capillary liquid chromatography [J].
Li, T ;
Coufal, P ;
Opekar, F ;
Stulík, K ;
Wang, E .
ANALYTICA CHIMICA ACTA, 1998, 360 (1-3) :53-59
[36]   Monitoring Insulin Aggregation via Capillary Electrophoresis [J].
Pryor, Elizabeth ;
Kotarek, Joseph A. ;
Moss, Melissa A. ;
Hestekin, Christa N. .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2011, 12 (12) :9369-9388
[37]   Capillary electrophoresis for monitoring bioprocesses [J].
Alhusban, Ala A. ;
Breadmore, Michael C. ;
Guijt, Rosanne M. .
ELECTROPHORESIS, 2013, 34 (11) :1465-1482
[38]   Programed nebulizing-gas pressure mode for quantitative capillary electrophoresis-mass spectrometry analysis of endocrine disruptors in honey [J].
Dominguez-Alvarez, Javier ;
Rodriguez-Gonzalo, Encarnacion ;
Hernandez-Mendez, Jesus ;
Carabias-Martinez, Rita .
ELECTROPHORESIS, 2012, 33 (15) :2374-2381
[39]   Amperometric detection of enzymes in capillary zone electrophoresis based on dynamic modification with surfactants [J].
Xu, DK ;
Lin, H ;
Chen, HY .
ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) :215-219
[40]   Amperometric detection for capillary electrophoresis at a sol-gel carbon composite electrode [J].
Hua, L ;
Tan, SN .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :179-186