Contribution of natural ventilation in a double skin envelope to heating load reduction in winter

被引:51
作者
Kim, Yu-Min [2 ]
Kim, Soo-Young [1 ]
Shin, Sung-Woo [3 ]
Sohn, Jang-Yeul [2 ]
机构
[1] Yonsei Univ, Dept Housing & Interior Design, Seoul 120749, South Korea
[2] Hanyang Univ, Dept Architectural Engn, Seoul 133791, South Korea
[3] Hanyang Univ, Dept Architectural Engn, Ansan, South Korea
关键词
Double skin envelope; Natural ventilation; Heating load; Energy saving;
D O I
10.1016/j.buildenv.2009.02.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examined the contribution of a double skin envelope (DSE) to the heating energy savings brought about by natural ventilation in office buildings. A DSE was applied to the east- and west-facing walls on an actual three-floor building. Field measurements and computer simulations were performed in winter. The results implied that the DSE on the west-facing wall contributed to energy savings when natural ventilation was supplied from the cavity to the indoor space. The DSE facing east was not recommended for energy savings by natural ventilation because of its smaller exposure to solar irradiance. Multiple linear regression models were developed based on field measurements to predict the temperature variation in the cavities, and effective control logics will be discussed in a future study. Of all variables, the outdoor air temperature was the most significant factor influencing the air temperature in the cavity. Computer simulation indicated that the air in the cavity was heated to the required temperature without consuming additional energy when the ratio of the diffused irradiance to global irradiance was smaller than 0.69. The cavity in the DSE worked as a thermal buffer zone and contributed to reducing heating energy consumption by 14.71% in January. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2236 / 2244
页数:9
相关论文
共 15 条
[1]  
ASHRAE, 2001, ANSI/ASHRAE/IESNA 90.1-2001 Energy Standard for Buildings except Low-Rise Residential Buildings
[2]  
ASHRAE (American Society of Heating Refrigerating and Air Conditioning Engineers), 1999, Ventilation for acceptable indoor air quality
[3]   Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin facade in Mediterranean climates [J].
Ballestini, G ;
De Carli, M ;
Masiero, N ;
Tombola, G .
BUILDING AND ENVIRONMENT, 2005, 40 (07) :983-995
[4]   Development and validation of regression models to predict monthly heating demand for residential buildings [J].
Catalina, Tiberiu ;
Virgone, Joseph ;
Blanco, Eric .
ENERGY AND BUILDINGS, 2008, 40 (10) :1825-1832
[5]   Energy conservation in honey storage building using Trombe wall [J].
Chel, Arvind ;
Nayak, J. K. ;
Kaushik, Geetanjali .
ENERGY AND BUILDINGS, 2008, 40 (09) :1643-1650
[6]  
Chen TY, 2003, SOL ENERGY, V74, P123, DOI 10.1016/S0038-092X(03)00119-l
[7]   Study of thermal behaviour of clay wall facing south [J].
Collet, F ;
Serres, L ;
Miriel, J ;
Bart, M .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :307-315
[8]  
COMPAGNO A., 1999, INTELLIGENT GLASS FA, V4th
[9]   Limits and potentials of office building climatisation with ambient air [J].
Eicker, U ;
Huber, M ;
Seeberger, P ;
Vorschulze, C .
ENERGY AND BUILDINGS, 2006, 38 (06) :574-581
[10]   Determining photosensor conditions of a daylight dimming control system using different double-skin envelope configurations [J].
Kim, S. Y. ;
Song, K. D. .
INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) :411-425