Graphene Oxide-Based Nanostructured DNA Sensor

被引:30
作者
Balaji, Aditya [1 ]
Yang, Songlin [2 ]
Wang, Jeslyn [2 ]
Zhang, Jin [1 ,2 ]
机构
[1] Univ Western Ontario, Dept Biomed Engn, London, ON N6A 5B9, Canada
[2] Univ Western Ontario, Dept Chem & Biochem Engn, London, ON N6A 5B9, Canada
来源
BIOSENSORS-BASEL | 2019年 / 9卷 / 02期
基金
加拿大自然科学与工程研究理事会;
关键词
DNA sensor; fluorescent magnetic core-shell nanoparticles; graphene oxide; FRET quenching mechanism; RESONANCE; NANOPARTICLES; ASSAY; FRET;
D O I
10.3390/bios9020074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quick detection of DNA sequence is vital for many fields, especially, early-stage diagnosis. Here, we develop a graphene oxide-based fluorescence quenching sensor to quickly and accurately detect small amounts of a single strand of DNA. In this paper, fluorescent magnetic nanoparticles (FMNPs) modified with target DNA sequence (DNA-t) were bound onto the modified graphene oxide acting as the fluorescence quenching element. FMNPs are made of iron oxide (Fe3O4) core and fluorescent silica (SiO2) shell. The average particle size of FMNPs was 74 +/- 6 nm and the average thickness of the silica shell, estimated from TEM results, was 30 +/- 4 nm. The photoluminescence and magnetic properties of FMNPs have been investigated. Target oligonucleotide (DNA-t) was conjugated onto FMNPs through glutaraldehyde crosslinking. Meanwhile, graphene oxide (GO) nanosheets were produced by a modified Hummers method. A complementary oligonucleotide (DNA-c) was designed to interact with GO. In the presence of GO-modified with DNA-c, the fluorescence intensity of FMNPs modified with DNA-t was quenched through a FRET quenching mechanism. Our study indicates that FMNPs can not only act as a FRET donor, but also enhance the sensor accuracy by magnetically separating the sensing system from free DNA and non-hybridized GO. Results indicate that this sensing system is ideal to detect small amounts of DNA-t with limitation detection at 0.12 mu M.
引用
收藏
页数:9
相关论文
共 30 条
[1]   Fast and fully-scalable synthesis of reduced graphene oxide [J].
Abdolhosseinzadeh, Sina ;
Asgharzadeh, Hamed ;
Kim, Hyoung Seop .
SCIENTIFIC REPORTS, 2015, 5
[2]  
Alexer LT., 2016, LANCET, V388, P1659
[3]   IUPAC-Consistent Approach to the Limit of Detection in Partial Least-Squares Calibration [J].
Allegrini, Franco ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :7858-7866
[4]   Chemical modifications and bioconjugate reactions of nanomaterials for sensing, imaging, drug delivery and therapy [J].
Biju, Vasudevanpillai .
CHEMICAL SOCIETY REVIEWS, 2014, 43 (03) :744-764
[5]   The chemistry of graphene oxide [J].
Dreyer, Daniel R. ;
Park, Sungjin ;
Bielawski, Christopher W. ;
Ruoff, Rodney S. .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (01) :228-240
[6]   Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano-gold immunological amplification and silver staining method [J].
Duan, LL ;
Wang, YF ;
Li, SSC ;
Wan, ZX ;
Zhai, JX .
BMC INFECTIOUS DISEASES, 2005, 5 (1)
[7]  
Ecsedy J., 2008, TXB CANC EPIDEMIOLOG, P61
[8]   The rise of graphene [J].
Geim, A. K. ;
Novoselov, K. S. .
NATURE MATERIALS, 2007, 6 (03) :183-191
[9]   THE RAPID DETECTION OF UNKNOWN MUTATIONS IN NUCLEIC-ACIDS [J].
GROMPE, M .
NATURE GENETICS, 1993, 5 (02) :111-117
[10]  
Hermanson GT, 2013, BIOCONJUGATE TECHNIQUES, 3RD EDITION, P959, DOI 10.1016/B978-0-12-382239-0.00023-6