Simultaneous determination of seven metabolites of organophosphate esters and 8-hydroxy-2′-deoxyguanosine in urine by high-performance liquid chromatography-tandem mass spectrometry with homemade mixed column purification

被引:2
作者
Li Dong [1 ,2 ]
Zhang Qin [2 ]
Zhang Shenghu [2 ]
Xu Cheng [2 ]
Chen Jianqiu [1 ]
Liu Yanhua [1 ]
Song Ninghui [2 ]
Guo Ruixin [1 ]
机构
[1] China Pharmaceut Univ, Sch Engn, Nanjing 211198, Peoples R China
[2] Minist Ecol & Environm, Nanjing Inst Environm Sci, Nanjing 210042, Peoples R China
基金
中国国家自然科学基金;
关键词
high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS); organophosphate ester (OPEs); metabolites; 8-hydroxy-2 '-deoxyguanosine (8-OHdG); urine; SOLID-PHASE EXTRACTION; FLAME-RETARDANT METABOLITES; VEGETABLES; EXPOSURE; SAMPLES; INDOOR; AIR;
D O I
10.3724/SP.J.1123.2019.10021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method based on high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with a small homemade mixed column was developed for the simultaneous determination of seven metabolites of organophosphate esters (OPEs) and 8-hydroxy-2'-deoxyguanosine (8-OHdG), an DNA oxidative damage marker, in urine. The urine samples were extracted by acetonitrile and enriched by the self-made column. All the samples were separated by gradient elution with acetonitrile-0.2% (v/v) ammonia solution, and then analyzed by an electrospray ionization source in negative ion multiple reaction monitoring mode. The results showed that the eight targets had good linearities in the range of 0.1-200 mu g/L. The recoveries of the seven metabolites of OPEs and 8-OHdG in urine samples were in the ranges of 52.36% to 114.56% and 88.63% to 97.72%, respectively. The established method was successfully applied for the determination of the abovementioned eight target compounds in real urine samples, with the mass concentrations of the seven metabolites of OPEs and 8-OHdG being 6.24-46.07 mu g/L and 5.90-16.71 mu g/L, respectively. In addition, significant correlations were found between 8-OHdG and the total content of the seven metabolites of OPEs. The established method is simple, sensitive, accurate, and reproducible, and it provides reliable technical support for a more comprehensive evaluation of the level of human exposure to OPEs and the resulting health hazards.
引用
收藏
页码:647 / 654
页数:8
相关论文
共 32 条
[31]  
Xe C, 2018, PHYS TESTING CHEM B, V54, P44
[32]   Occurrence, distribution and risk assessment of organophosphate esters in surface water and sediment from a shallow freshwater Lake, China [J].
Xing, Liqun ;
Zhang, Qin ;
Sun, Xu ;
Zhu, Hongxia ;
Zhang, Shenghu ;
Xu, Huaizhou .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 636 :632-640